hazardous-waste-properties-ann-3-dir-2008-98

Waste Framework Directive, Annex III - Waste - Hazardous Properties

EU. Substances according to Hazardous Waste Properties: Annex III, Directive 2008/98/EC, 22 November 2008, amended by Directive 2018/851/EU, 14 June 2018

This list contains substances that have been assigned hazard property (HP) waste codes 1-15, as defined in terms of the hazard class and category, hazard (H) statement, and/or concentration limits provided in Annex III of the Waste Framework Directive 2008/98/EC. The classifications of the substances listed in the list are based on their harmonised classifications per Table 3 of Annex VI to the CLP Regulation 1272/2008/EC.

Last updated 04 listopada 2024. Database contains 4748 unique substances/entries.
Filter the list

201-083-8
78-10-4
Flam. Liq. 3
Acute Tox. 4
STOT SE 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
014-005-00-0
202-851-5
100-42-5
Flam. Liq. 3
Repr. 2
Acute Tox. 4
STOT RE 1
Skin Irrit. 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP10 Toxic for reproduction: waste which has adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
601-026-00-0
611-802-0
591-34-4
Flam. Liq. 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
607-029-00-3
ALKYL ISOCYANATE SILANE SCD 617
402-290-8
85702-90-5
Flam. Liq. 3
Resp. Sens. 1
Skin Sens. 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
607-184-00-7
R633
406-230-1
224635-63-6
Flam. Liq. 3
Carc. 2
Skin Corr. 1B
Acute Tox. 4
Skin Sens. 1
Aquatic Acute 1
Aquatic Chronic 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
650-018-00-3
414-340-6
-
Flam. Liq. 3
Acute Tox. 4
STOT SE 2
Eye Dam. 1
Skin Sens. 1
Aquatic Chronic 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
612-228-00-3
MCP 455
406-240-6
-
Flam. Liq. 3
Skin Corr. 1B
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
015-172-00-2
(R)-EPICHLOROHYDRIN
424-280-2
51594-55-9
Flam. Liq. 3
Carc. 1B
Acute Tox. 3
Skin Corr. 1B
Skin Sens. 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
603-166-00-8
201-155-9
78-90-0
Flam. Liq. 3
Acute Tox. 4
Skin Corr. 1A
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP8 Corrosive: waste which on application can cause skin corrosion.
612-100-00-7
203-132-9
103-65-1
Flam. Liq. 3
Asp. Tox. 1
STOT SE 3
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
601-097-00-8
203-389-7
106-36-5
Flam. Liq. 3
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
607-030-00-9
203-471-2
107-19-7
Flam. Liq. 3
Acute Tox. 3
Skin Corr. 1B
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
603-078-00-X
201-186-8
79-21-0
Flam. Liq. 3
Org. Perox. D
Acute Tox. 4
Skin Corr. 1A
Aquatic Acute 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-094-00-8
210-852-7
624-54-4
Flam. Liq. 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
607-131-00-8
211-340-6
638-49-3
Flam. Liq. 3
STOT SE 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
607-696-00-0
211-047-3
628-63-7
Flam. Liq. 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
607-130-00-2
250-378-8
30899-19-5
Flam. Liq. 3
Acute Tox. 4
STOT SE 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
603-006-00-7
204-634-0
123-54-6
Flam. Liq. 3
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
606-029-00-0
206-050-1
298-00-0
Flam. Liq. 3
Acute Tox. 2
Acute Tox. 3
STOT RE 2
Aquatic Acute 1
Aquatic Chronic 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
015-035-00-7
203-396-5
106-42-3
Flam. Liq. 3
Acute Tox. 4
Skin Irrit. 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
601-022-00-9
202-795-1
99-86-5
Flam. Liq. 3
Acute Tox. 4
Skin Sens. 1
Asp. Tox. 1
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
601-095-00-7
202-422-2
95-47-6
Flam. Liq. 3
Acute Tox. 4
Skin Irrit. 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
601-022-00-9
434-350-4
103122-66-3
Flam. Liq. 3
Carc. 1B
Muta. 1B
Acute Tox. 4
STOT RE 2
Skin Sens. 1
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
006-094-00-X
200-876-6
75-52-5
Flam. Liq. 3
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
609-036-00-7
201-188-9
79-24-3
Flam. Liq. 3
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
609-035-00-1