hazardous-waste-properties-ann-3-dir-2008-98

Waste Framework Directive, Annex III - Waste - Hazardous Properties

EU. Substances according to Hazardous Waste Properties: Annex III, Directive 2008/98/EC, 22 November 2008, amended by Directive 2018/851/EU, 14 June 2018

This list contains substances that have been assigned hazard property (HP) waste codes 1-15, as defined in terms of the hazard class and category, hazard (H) statement, and/or concentration limits provided in Annex III of the Waste Framework Directive 2008/98/EC. The classifications of the substances listed in the list are based on their harmonised classifications per Table 3 of Annex VI to the CLP Regulation 1272/2008/EC.

Last updated 08 listopada 2024. Database contains 4748 unique substances/entries.
Filter the list

A complex combination of hydrocarbons obtained from stripping stabilization of catalytic hydrodesulfurized vacuum gas oil and from which hydrogen sulfide has been removed by amine treatment. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
269-627-7
68308-07-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-187-00-6
A complex combination of hydrocarbons obtained from hydrodesulfurization of straight-run naphtha. It consists of hydrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-810-9
68478-30-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-144-00-1
A complex combination of hydrocarbons obtained from fractionation of hydrodesulfurized naphtha and distillate hydrocarbon streams and treated to remove acidic impurities. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
269-626-1
68308-06-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-186-00-0
A complex combination of hydrocarbons from the distillation of products from miscellaneous hydrocarbon streams. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
269-624-0
68308-04-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-184-00-X
A complex combination of hydrocarbons from the distillation of products from miscellaneous hydrocarbon streams. It consists of hydrocarbon having carbon numbers predominantly in the range of C1 through C4.
269-625-6
68308-05-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-185-00-5
A complex combination of hydrocarbons obtained from the distillation of products from the catalytic cracking of gas oil. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
269-623-5
68308-03-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-183-00-4
A complex combination of hydrocarbons obtained by treating thermal cracked distillates with hydrogen in the presence of a catalyst. It consists predominantly of saturated hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
269-620-9
68308-01-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-181-00-3
A complex combination of hydrocarbons obtained by treating cracked distillates with hydrogen in the presence of a catalyst. It consists of hydrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-809-3
68478-29-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-143-00-6
A complex combination of hydrocarbons obtained from the stabilization of catalytic reformed naphtha. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-808-8
68478-28-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-142-00-0
A complex combination of hydrocarbons obtained from the catalytic reforming of straight run naphtha. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-807-2
68478-27-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-141-00-5
A complex combination of hydrocarbons obtained from the fractionation stabilization of catalytic reformed naphtha. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
270-806-7
68478-26-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-079-00-9
A complex combination of hydrocarbons obtained from fractionation stabilization of catalytic reformed naphtha and from which hydrogen sulfide has been removed by amine treatment. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
269-619-3
68308-00-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-180-00-8
A complex combination of hydrocarbons from the fractionation stabilization products from polymerization of naphtha. It consists predominantly of hydrocarbons having carbon numbers in the range of C1 through C4.
269-618-8
68307-99-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-179-00-2
A complex combination of hydrocarbons obtained from the hydrodesulfurization of naphtha. It consists of hydrogen, methane, ethane, and propane.
273-173-5
68952-79-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-165-00-6
A complex combination of hydrocarbons obtained from the fractionation of products from catalytic cracking, catalytic reforming and hydrodesulfurizing processes treated to remove acidic impurities. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-804-6
68478-24-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-078-00-3
A complex combination of hydrocarbons obtained from refractionation of products from a catalytic cracking process. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
270-805-1
68478-25-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-140-00-X
A complex combination of hydrocarbons obtained from the stabilization of catalytic cracked naphtha. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-803-0
68478-22-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-077-00-8
A complex combination of hydrocarbons obtained by the fractionation of catalytic cracked naphtha and distillate. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
273-170-9
68952-77-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-108-00-5
The complex combination of hydrocarbons from the distillation of the products from catalytic cracked distillates and catalytic cracked naphtha. It consists predominantly of hydrocarbons having carbon numbers in the range of C1 through C4.
269-617-2
68307-98-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-178-00-7
A complex combination of hydrocarbons obtained from fractionation of catalytic cracked clarified oil and thermal cracked vacuum residue. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-802-5
68478-21-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-076-00-2
202-851-5
100-42-5
Flam. Liq. 3
Repr. 2
Acute Tox. 4
STOT RE 1
Skin Irrit. 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP10 Toxic for reproduction: waste which has adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
601-026-00-0
204-699-5
124-41-4
Self-heat. 1
Skin Corr. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP8 Corrosive: waste which on application can cause skin corrosion.
603-040-00-2
231-587-3
7646-69-7
Water-react. 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
001-003-00-X
205-487-5
141-52-6
Self-heat. 1
Skin Corr. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP8 Corrosive: waste which on application can cause skin corrosion.
603-041-00-8
231-890-0
7775-14-6
Self-heat. 1
Acute Tox. 4
EUH031
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP12 Release of an acute toxic gas: waste which releases acute toxic gases (Acute Tox. 1, 2 or 3) in contact with water or an acid.
016-028-00-1
NA-2-ETHYLHEXANOLAT
406-150-7
38411-13-1
Flam. Sol. 1
Skin Corr. 1B
Aquatic Chronic 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
603-122-00-8
EURESYNTH(R) 5010
418-720-2
-
Flam. Sol. 1
Water-react. 1
Pyr. Sol. 1
Acute Tox. 4
Skin Corr. 1A
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP8 Corrosive: waste which on application can cause skin corrosion.
013-009-00-X
231-132-9
7440-23-5
Water-react. 1
Skin Corr. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP8 Corrosive: waste which on application can cause skin corrosion.
011-001-00-0
237-732-7
13952-84-6
Flam. Liq. 2
Acute Tox. 4
Skin Corr. 1A
Aquatic Acute 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
612-052-00-7
611-802-0
591-34-4
Flam. Liq. 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
607-029-00-3
213-104-8
924-43-6
Flam. Liq. 2
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
007-018-00-8
203-300-1
105-46-4
Flam. Liq. 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
607-026-00-7
ALKYL ISOCYANATE SILANE SCD 617
402-290-8
85702-90-5
Flam. Liq. 3
Resp. Sens. 1
Skin Sens. 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
607-184-00-7
R-GLYCIDOL
404-660-4
57044-25-4
Self-react. C
Carc. 1B
Muta. 2
Repr. 1B
Acute Tox. 3
Acute Tox. 4
Skin Corr. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP10 Toxic for reproduction: waste which has adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
603-143-00-2
A complex residuum from the distillation of streams from various refinery operations. It consists of hydrocarbons having carbon numbers in the range of C4 through C5, predominantly butane and boiling in the range of approximately -11.7°C to 27.8°C (11°F to 82°F).
271-010-2
68513-66-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-087-00-2
231-768-7
7723-14-0
Flam. Sol. 1
Aquatic Chronic 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
015-002-00-7
ORGANOTUNGSTEN COMPOUND CONCENTRATE
408-250-6
121754-49-2
Flam. Liq. 2
Acute Tox. 4
Skin Corr. 1B
Skin Sens. 1
Aquatic Acute 1
Aquatic Chronic 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
074-002-00-5
PES-SOLID
420-070-1
-
Org. Perox. D
Acute Tox. 4
Skin Corr. 1A
Aquatic Acute 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
650-048-00-7
R633
406-230-1
224635-63-6
Flam. Liq. 3
Carc. 2
Skin Corr. 1B
Acute Tox. 4
Skin Sens. 1
Aquatic Acute 1
Aquatic Chronic 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
650-018-00-3
TYZOR ZEC
417-110-3
1379678-99-5
Flam. Liq. 2
Skin Irrit. 2
Eye Dam. 1
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
650-045-00-0
SHC 3000
401-530-9
-
Flam. Sol. 1
STOT SE 1
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
014-022-00-3
438-310-7
-
Self-react. C
Repr. 2
Acute Tox. 4
STOT RE 2
Aquatic Chronic 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP10 Toxic for reproduction: waste which has adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
611-172-00-7
T-271
417-980-4
157321-59-0
Self-react. C
Carc. 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
016-095-00-7
414-340-6
-
Flam. Liq. 3
Acute Tox. 4
STOT SE 2
Eye Dam. 1
Skin Sens. 1
Aquatic Chronic 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
612-228-00-3
MCP 455
406-240-6
-
Flam. Liq. 3
Skin Corr. 1B
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
015-172-00-2
T-69
414-770-4
140698-96-0
Self-react. C
Carc. 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
016-093-00-6
34 DIAZO
417-080-1
-
Self-react. D
Skin Sens. 1
Aquatic Acute 1
Aquatic Chronic 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-449-00-7
429-710-2
-
Self-react. D
Acute Tox. 4
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
611-164-00-3
PEROXIMON 180
412-140-3
32144-25-5
Org. Perox. D
Aquatic Chronic 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
617-017-00-X
PEROXIMON S 168 TECHNICALLY PURE
410-840-3
71566-50-2
Org. Perox. C
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
617-018-00-5

Export search results to: