hazardous-waste-properties-ann-3-dir-2008-98

Waste Framework Directive, Annex III - Waste - Hazardous Properties

EU. Substances according to Hazardous Waste Properties: Annex III, Directive 2008/98/EC, 22 November 2008, amended by Directive 2018/851/EU, 14 June 2018

This list contains substances that have been assigned hazard property (HP) waste codes 1-15, as defined in terms of the hazard class and category, hazard (H) statement, and/or concentration limits provided in Annex III of the Waste Framework Directive 2008/98/EC. The classifications of the substances listed in the list are based on their harmonised classifications per Table 3 of Annex VI to the CLP Regulation 1272/2008/EC.

Last updated 12 srpnja 2024. Database contains 4748 unique substances/entries.
Filter the list

429-800-1
95737-68-1
Aquatic Acute 1
Aquatic Chronic 1
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
613-303-00-3
213-482-4
957-51-7
Acute Tox. 4
Aquatic Chronic 3
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
616-007-00-2
DIETHYLDIMETHYLAMMONIUMHYDROXIDE
419-400-5
95500-19-9
Acute Tox. 4
Skin Corr. 1A
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP8 Corrosive: waste which on application can cause skin corrosion.
007-029-00-8
306-004-1
95465-89-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-118-00-X
ESACURE TZT 100
403-150-9
954-16-5
Acute Tox. 4
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
606-044-00-2
305-975-9
95371-08-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-511-00-6
305-974-3
95371-07-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-510-00-0
305-972-2
95371-05-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-509-00-5
305-971-7
95371-04-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-508-00-X
-
953-17-3
Acute Tox. 3
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
015-132-00-4