hazardous-waste-properties-ann-3-dir-2008-98

Waste Framework Directive, Annex III - Waste - Hazardous Properties

EU. Substances according to Hazardous Waste Properties: Annex III, Directive 2008/98/EC, 22 November 2008, amended by Directive 2018/851/EU, 14 June 2018

This list contains substances that have been assigned hazard property (HP) waste codes 1-15, as defined in terms of the hazard class and category, hazard (H) statement, and/or concentration limits provided in Annex III of the Waste Framework Directive 2008/98/EC. The classifications of the substances listed in the list are based on their harmonised classifications per Table 3 of Annex VI to the CLP Regulation 1272/2008/EC.

Last updated 06 rujna 2024. Database contains 4748 unique substances/entries.
Filter the list

A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C9 through C16 and boiling in the range of approximately 150°C to 290°C (302°F to 554°F).
265-132-5
64742-31-0
Asp. Tox. 1
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-421-00-7
A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C11 through C20 and boiling in the range of approximately 205°C to 345°C (401°F to 653°F).
265-130-4
64742-30-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-219-00-9
A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C13 through C25 and boiling in the range of approximately 230°C to 400°C (446°F to 752°F).
265-129-9
64742-29-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-218-00-3
A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil with a viscosity less than 100 SUS at 100°F (19cSt at 40°C).
265-128-3
64742-28-5
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-059-00-X
A complex combination of hydrocarbons obtained from a treating process to remove acidic materials. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity of at least 100 SUS at 100°F (19cSt at 40°C). It contains a relatively large proportion of aliphatic hydrocarbons.
265-127-8
64742-27-4
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-058-00-4
A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C4 through C11 and boiling in the range of approximately minus 20°C to 190°C (-4°F to 374°F).
265-123-6
64742-23-0
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-353-00-8
A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C6 through C12 and boiling in the range of approximately 65°C to 230°C (149°F to 446°F).
265-122-0
64742-22-9
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-352-00-2
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists predominantly of saturated hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil having a viscosity of less than 100 SUS at 100°F (19cSt at 40°C).
265-121-5
64742-21-8
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-057-00-9
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid process. It consists predominantly of saturated hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil having a viscosity of at least 100 SUS at 100°F (19cSt at 40°C).
265-119-4
64742-20-7
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-056-00-3
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil with a viscosity of less than 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-118-9
64742-19-4
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-055-00-8
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity of at least 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-117-3
64742-18-3
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-054-00-2
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists of hydrocarbons having carbon numbers predominantly in the range of C7 through C12 and boiling in the range of approximately 90°C to 230°C (194°F to 446°F).
265-115-2
64742-15-0
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-351-00-7
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists of hydrocarbons having carbon numbers predominantly in the range of C9 through C16 and boiling in the range of approximately 150°C to 290°C (302°F to 554°F).
265-114-7
64742-14-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-217-00-8
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists of hydrocarbons having carbon numbers predominantly in the range of C11 through C20 and boiling in the range of approximately 205°C to 345°C (401°F to 653°F).
265-113-1
64742-13-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-216-00-2
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists of hydrocarbons having carbon numbers predominantly in the range of C13 through C25 and boiling in the range of approximately 230°C to 400°C (446°F to 752°F).
265-112-6
64742-12-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-215-00-7
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C20 through C50. This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-111-0
64742-11-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-004-00-X
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C15 through C30. This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-104-2
64742-05-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-003-00-4
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C20 through C50. This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-103-7
64742-04-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-002-00-9
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C15 through C30. This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-102-1
64742-03-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-001-00-3
A complex combination of hydrocarbons obtained as the solvent insoluble fraction from solvent refining of a residuum using a polar organic solvent such as phenol or furfural. It consists of hydrocarbons having carbon numbers predominantly higher than C25 and boiling above approximately 400°C (752°F).
265-101-6
64742-01-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-459-00-4
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C7 through C12 and boiling in the range of approximately 90°C to 220°C (194°F to 428°F).
265-099-7
64741-98-6
Asp. Tox. 1
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-420-00-1
A complex combination of hydrocarbons obtained as the raffinate from a solvent extraction process. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil with a viscosity of less than 100 SUS at 100°F (19 cSt at 40°C). It contains relatively few normal paraffins.
265-098-1
64741-97-5
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-458-00-9
A complex combination of hydrocarbons obtained as the raffinate from a solvent extraction process. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity of at least 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-097-6
64741-96-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-457-00-3
A complex combination of hydrocarbons obtained as the solvent soluble fraction from C3 - C4 solvent deasphalting of a residuum. It consists of hydrocarbons having carbon numbers predominantly higher than C25 and boiling above approximately 400°C (752°F).
265-096-0
64741-95-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-456-00-8
A complex combination of hydrocarbons obtained as the raffinate from a solvent extraction process. It consists predominantly of aliphatic hydrocarbons having carbon numbers predominantly in the range of C7 through C12 and boiling in the range of approximately 90°C to 230°C (194°F to 446°F).
265-095-5
64741-92-0
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-279-00-6

Export search results to: