hazardous-waste-properties-ann-3-dir-2008-98

Waste Framework Directive, Annex III - Waste - Hazardous Properties

EU. Substances according to Hazardous Waste Properties: Annex III, Directive 2008/98/EC, 22 November 2008, amended by Directive 2018/851/EU, 14 June 2018

This list contains substances that have been assigned hazard property (HP) waste codes 1-15, as defined in terms of the hazard class and category, hazard (H) statement, and/or concentration limits provided in Annex III of the Waste Framework Directive 2008/98/EC. The classifications of the substances listed in the list are based on their harmonised classifications per Table 3 of Annex VI to the CLP Regulation 1272/2008/EC.

Last updated 17 srpnja 2024. Database contains 4748 unique substances/entries.
Filter the list

208-846-4
543-59-9
Flam. Liq. 2
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
602-022-00-1
208-749-7
540-54-5
Flam. Liq. 2
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
602-018-00-X
203-556-4
108-16-7
Flam. Liq. 3
Acute Tox. 4
Skin Corr. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
603-077-00-4
211-420-0
644-64-4
Acute Tox. 3
Acute Tox. 4
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
613-047-00-2
216-374-5
1569-02-4
Flam. Liq. 3
STOT SE 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
603-177-00-8
201-091-1
78-18-2
Org. Perox. A
Skin Corr. 1B
Acute Tox. 4
HP1 Explosive: waste which is capable by chemical reaction of producing gas at such a temperature and pressure and at such a speed as to cause damage to the surroundings. Pyrotechnic waste, explosive organic peroxide waste and explosive self-reactive waste is included.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
617-010-00-1
201-091-1
78-18-2
Org. Perox. C
Acute Tox. 4
Skin Corr. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
617-010-01-9
219-989-7
2592-95-2
Expl. 1.3
HP1 Explosive: waste which is capable by chemical reaction of producing gas at such a temperature and pressure and at such a speed as to cause damage to the surroundings. Pyrotechnic waste, explosive organic peroxide waste and explosive self-reactive waste is included.
613-285-00-7
204-318-2
119-38-0
Acute Tox. 1
Acute Tox. 2
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
006-009-00-6
202-796-7
99-87-6
Flam. Liq. 3
Acute Tox. 3
Asp. Tox. 1
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
601-094-00-1

Export search results to: