hazardous-waste-properties-ann-3-dir-2008-98

Waste Framework Directive, Annex III - Waste - Hazardous Properties

EU. Substances according to Hazardous Waste Properties: Annex III, Directive 2008/98/EC, 22 November 2008, amended by Directive 2018/851/EU, 14 June 2018

This list contains substances that have been assigned hazard property (HP) waste codes 1-15, as defined in terms of the hazard class and category, hazard (H) statement, and/or concentration limits provided in Annex III of the Waste Framework Directive 2008/98/EC. The classifications of the substances listed in the list are based on their harmonised classifications per Table 3 of Annex VI to the CLP Regulation 1272/2008/EC.

Last updated 14 lipnja 2024. Database contains 4748 unique substances/entries.
Filter the list

270-681-9
68476-40-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-199-00-1
A complex combination of hydrocarbons produced by distillation and condensation of crude oil. It consists of hydrocarbons having carbon numbers in the range of C3 through C5, predominantly C3 through C4.
270-990-9
68512-91-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-083-00-0
A complex combination of hydrocarbons produced by the distillations of products from a catalytic cracking process. It consists of hydrocarbons having carbon numbers predominantly in the range of C3 through C11 and boiling in a range approximately up to 204°C(400°F).
270-686-6
68476-46-0
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-291-00-1
308-133-9
97862-83-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-521-00-0
308-287-7
97926-68-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-522-00-6
308-290-3
97926-71-1
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-524-00-7
308-131-8
97862-81-2
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-519-00-X
308-289-8
97926-70-0
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-523-00-1
A complex combination of hydrocarbons produced by treating dewaxed heavy paraffinic distillate with hydrogen in the presence of a catalyst. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C20 through C50.
292-617-9
90640-95-2
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-488-00-2
300-257-1
93924-61-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-503-00-2
270-687-1
68476-47-1
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-302-00-X
271-734-9
68606-25-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-093-00-5
270-689-2
68476-49-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-201-00-0
A complex combination of hydrocarbons obtained as first runnings from the vacuum distillation of effluents from the catalytic hydrotreatment of a solvent deasphalted short residue having a viscosity of 8cSt at approximately 100°C (212°F). It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C17 through C40 and boiling in the range of approximately 300°C to 500°C (592°F to 932°F).
307-755-8
97722-06-0
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-516-00-3
A complex combination of hydrocarbons obtained as first runnings from the vacuum distillation of effluents from the treatment of a solvent-deasphalted short residue with hydrogen in the presence of a catalyst. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C17 through C30 and boiling in the range of approximately 300°C to 400°C (572°F to 752°F). It produces a finished oil having a viscosity of 4cSt at approximately 100°C (212°F).
307-661-7
97675-87-1
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-515-00-8
308-132-3
97862-82-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-520-00-5
305-972-2
95371-05-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-509-00-5
A complex combination of hydrocarbons obtained by solvent dewaxing of a distillation residue from a hydrocracked paraffinic distillate. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C16 through C20 and boiling in the range of approximately 360°C to 500°C (680°F to 932°F). It produces a finished oil having a viscosity of 4.5cSt at approximately 100°C (212°F).
307-662-2
97675-88-2
Carc. 2
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-449-00-X
A complex combination of hydrocarbons obtained as first runnings from the vacuum distillation of effluents from the treatment of a middle distillate with hydrogen. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C16 through C20 and boiling in the range of approximately 290°C to 350°C (554°F to 662°F). It produces a finished oil having a viscosity of 2cSt at 100°C (212°F).
307-659-6
97675-85-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-235-00-6
A complex combination of hydrocarbons obtained by extraction of the aromatics from a light naphthenic distillate having a viscosity of 16cSt at 40°C (104°F). It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C14 through C29 and boiling in the range of approximately 250°C to 425°C (482°F to 797°F).
307-760-5
97722-10-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-518-00-4
305-971-7
95371-04-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-508-00-X
A complex combination of hydrocarbons obtained by extraction of the aromatics from a light naphthenic distillate having a viscosity of 9.5cSt at 40°C (104°F). It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C13 through C27 and boiling in the range of approximately 240°C to 400°C (464°F to 752°F).
307-758-4
97722-09-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-517-00-9
A complex combination of hydrocarbons obtained as first runnings from the vacuum distillation of effluents from the treatment of heavy paraffins with hydrogen in the presence of a catalyst. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C12 through C20 and boiling in the range of approximately 230°C to 350°C (446°F to 662°F). It produces a finished oil having a viscosity of 2cSt at 100°C (212°F).
307-660-1
97675-86-0
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-236-00-1
A complex combination of hydrocarbons obtained by extraction of the aromatics from a light naphthenic distillate having a viscosity of 2.2cSt at 40°C (104°F). It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C11 through C17 and boiling in the range of approximately 200°C to 300°C (392°F to 572°F).
307-757-9
97722-08-2
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-237-00-7
A complex combination of hydrocarbons produced by thermal cracking and absorber operations and by distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C4 and boiling in the range of approximately minus 164°C to minus 0.5°C (-263°F to 31°F).
271-032-2
68514-31-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-088-00-8
A complex combination of hydrocarbons obtained by subjecting hydrocarbon gases to a sweetening process to convert mercaptans or to remove acidic impurities. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C4 and boiling in the range of approximately -164°C to -0.5°C(-263°F to 31°F).
271-038-5
68514-36-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-089-00-3
271-261-8
68527-19-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-091-00-4
A complex combination of hydrocarbons having carbon numbers predominantly in the range of C1 through C3 and boiling in the range of approximately minus 164°C to minus 42°C (-263°F to -44°F).
271-259-7
68527-16-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-090-00-9
A complex combination of hydrocarbons obtained by solvent extraction from a naphthenic distillate having a viscosity of 27cSt at 100°C (212°F). It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C26 through C55 and boiling in the range of approximately 395°C to 640°C (743°F to 1184°F).
307-753-7
97722-04-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-006-00-0
The oil obtained from the heat treatment of polystyrene with coal tar pitch or aromatic oils. It consists predominantly of benzene and its homologs boiling in a range of approximately 70°C to 210°C (158°F to 410°F).
309-749-0
100801-66-9
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-136-00-5
The oil obtained from the heat treatment of polyethylene with coal tar pitch or aromatic oils. It consists predominantly of benzene and its homologs boiling in a range of 70°C to 120°C (158°F to 248°F).
309-748-5
100801-65-8
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-135-00-X
The oil obtained from the heat treatment of a polyethylene/polypropylene mixture with coal tar pitch or aromatic oils. It consists predominantly of benzene and its homologs boiling in a range of approximately 70°C to 120°C (158°F to 248°F).
309-745-9
100801-63-6
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-134-00-4
233-113-0
10035-10-6
Skin Corr. 1B
STOT SE 3
HP8 Corrosive: waste which on application can cause skin corrosion.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
035-002-01-8
233-113-0
10035-10-6
Skin Corr. 1A
STOT SE 3
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
035-002-00-0
233-109-9
10034-85-2
Skin Corr. 1B
HP8 Corrosive: waste which on application can cause skin corrosion.
053-002-01-6
233-109-9
10034-85-2
Skin Corr. 1A
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP8 Corrosive: waste which on application can cause skin corrosion.
053-002-00-9
204-563-5
122-66-7
Carc. 1B
Acute Tox. 4
Aquatic Acute 1
Aquatic Chronic 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
007-021-00-4
-
14913-74-7
Expl. 1.1
Self-react. A
Carc. 1B
Acute Tox. 3
Skin Sens. 1
HP1 Explosive: waste which is capable by chemical reaction of producing gas at such a temperature and pressure and at such a speed as to cause damage to the surroundings. Pyrotechnic waste, explosive organic peroxide waste and explosive self-reactive waste is included.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
609-053-00-X
STABO-FIX
405-030-1
148434-03-1
Carc. 1B
Acute Tox. 4
Skin Corr. 1B
Skin Sens. 1
Aquatic Chronic 3
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
007-022-00-X
206-114-9
302-01-2
Flam. Liq. 3
Carc. 1B
Acute Tox. 3
Skin Corr. 1B
Skin Sens. 1
Aquatic Acute 1
Aquatic Chronic 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
007-008-00-3
616-638-3
78587-05-0
Aquatic Acute 1
Aquatic Chronic 1
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
613-125-00-6
219-698-5
2499-95-8
STOT SE 3
Skin Irrit. 2
Skin Sens. 1
Aquatic Chronic 2
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-233-00-2
257-074-4
51235-04-2
Acute Tox. 4
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
613-132-00-4
NATRIUMMETAWOLFRAMAT
412-770-9
12141-67-2
Acute Tox. 4
Eye Dam. 1
Aquatic Chronic 3
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
074-001-00-X
BROWN MO 384; BRUN MO 384; INDOSOL BRAUN SF-BR; INDOSOL BROWN SF-BR; INDOSOL BRUIN SF-BR
400-020-3
82027-60-9
Aquatic Chronic 2
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
611-033-00-0
BRUN REACTIF 45; BRUNO REATTIVO 45; C.I. REACTIVE BROWN 45; CIBACROM BROWN 1347; CIBACRON BROWN 1347; REACTIVE BRAUN 45
401-650-1
85665-96-9
Skin Sens. 1
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
016-047-00-5
C.I. BLEU REACTIF 204; C.I. REACTIVE BLUE 204; REACTIVE BLUE 204; REAKTIV BLAU 204
400-050-7
85153-92-0
Resp. Sens. 1
Skin Sens. 1
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
613-093-00-3
RED SF-PE 3534
410-180-6
157627-99-1
Eye Dam. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
611-106-00-7
C.I. REACTIVE BLUE 217
412-240-7
89797-03-5
Aquatic Chronic 2
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
611-095-00-9
PROCION EMERALD H-EXL COLOUR; SUBSTANCE S156718
417-250-5
151436-99-6
Eye Dam. 1
Skin Sens. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
611-122-00-4
247-143-7
25637-27-8
Acute Tox. 4
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
050-009-00-9
-
-
Flam. Liq. 2
Asp. Tox. 1
Skin Irrit. 2
STOT SE 3
Aquatic Chronic 2
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
601-007-00-7
209-731-1
591-78-6
Flam. Liq. 3
Repr. 2
STOT RE 1
STOT SE 3
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP10 Toxic for reproduction: waste which has adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
606-030-00-6
203-852-3
111-27-3
Acute Tox. 4
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
603-059-00-6
211-653-8
680-31-9
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
015-106-00-2
204-679-6
124-09-4
Acute Tox. 4
STOT SE 3
Skin Corr. 1B
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP8 Corrosive: waste which on application can cause skin corrosion.
612-104-00-9
212-485-8
822-06-0
Acute Tox. 3
STOT SE 3
Skin Irrit. 2
Resp. Sens. 1
Skin Sens. 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
615-011-00-1
235-921-9
13048-33-4
Skin Irrit. 2
Skin Sens. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
607-109-00-8
DIRECT RED 227, TETRAMETHYLAMMONIUM SALT
405-160-9
124537-30-0
Acute Tox. 3
Skin Sens. 1
Aquatic Chronic 3
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
613-105-00-7
247-094-1
25550-51-0
Eye Dam. 1
Resp. Sens. 1
Skin Sens. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
607-241-00-6
AMINAZA TOLFAMATATE
418-350-1
-
Muta. 2
Acute Tox. 4
Skin Sens. 1
Aquatic Chronic 2
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
016-081-00-0
243-072-0
19438-60-9
Eye Dam. 1
Resp. Sens. 1
Skin Sens. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
607-241-00-6
260-566-1
57110-29-9
Eye Dam. 1
Resp. Sens. 1
Skin Sens. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
607-241-00-6
256-356-4
48122-14-1
Eye Dam. 1
Resp. Sens. 1
Skin Sens. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
607-241-00-6
204-127-4
116-15-4
Acute Tox. 4
STOT SE 3
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
602-061-00-4
401-400-1
86479-06-3
Aquatic Acute 1
Aquatic Chronic 1
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
616-221-00-6
C-1742
418-550-9
168689-49-4
Aquatic Chronic 4
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-479-00-0
428-140-1
210706-50-6
Aquatic Chronic 4
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-590-00-4
424-830-1
220229-87-8
Aquatic Chronic 4
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-552-00-7
HEXACONAZOLE
413-050-7
79983-71-4
Acute Tox. 4
Skin Sens. 1
Aquatic Chronic 2
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
613-171-00-7
241-010-7
16941-12-1
Acute Tox. 3
Skin Corr. 1B
Resp. Sens. 1
Skin Sens. 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
078-009-00-4
show/hide
Hexachloroplatinate(2-) EC / List no: - | CAS no: 16871-54-8
Dicesium hexachloroplatinate EC / List no: 240-945-8 | CAS no: 16902-25-3
Natriumchloroplatinat EC / List no: 626-326-9 | CAS no: 19583-77-8
Diammonium hexachloroplatinate EC / List no: 240-973-0 | CAS no: 16919-58-7
Dipotassium hexachloroplatinate EC / List no: 240-979-3 | CAS no: 16921-30-5
Bis(benzyltrimethylammonium) hexachloroplatinate(2-) EC / List no: 255-585-7 | CAS no: 41909-89-1
Disodium hexachloroplatinate EC / List no: 240-983-5 | CAS no: 16923-58-3
Chloroplatinic acid hexahydrate EC / List no: 629-612-1 | CAS no: 18497-13-7
Hexachloroplatinic acid EC / List no: 241-010-7 | CAS no: 16941-12-1
-
-
Acute Tox. 3
Eye Dam. 1
Resp. Sens. 1
Skin Sens. 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
078-005-00-2
201-029-3
77-47-4
Acute Tox. 2
Acute Tox. 3
Acute Tox. 4
Skin Corr. 1B
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
602-078-00-7
204-273-9
118-74-1
Carc. 1B
STOT RE 1
Aquatic Acute 1
Aquatic Chronic 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
602-065-00-6
204-129-5
116-16-5
Acute Tox. 4
Aquatic Chronic 2
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
606-032-00-7
show/hide
gamma-hexabromocyclododecane EC / List no: 603-804-5 | CAS no: 134237-52-8
Hexabromocyclododecane EC / List no: 247-148-4 | CAS no: 25637-99-4
alpha-hexabromocyclododecane EC / List no: 603-801-9 | CAS no: 134237-50-6
1,2,5,6,9,10-hexabromocyclodecane EC / List no: 221-695-9 | CAS no: 3194-55-6
beta-hexabromocyclododecane EC / List no: 603-802-4 | CAS no: 134237-51-7
247-148-4
25637-99-4
Repr. 2
HP10 Toxic for reproduction: waste which has adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring.
602-109-00-4
245-737-0
23560-59-0
Acute Tox. 3
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
015-126-00-1
203-838-7
111-14-8
Skin Corr. 1B
HP8 Corrosive: waste which on application can cause skin corrosion.
607-196-00-2
205-563-8
142-82-5
Flam. Liq. 2
Asp. Tox. 1
Skin Irrit. 2
STOT SE 3
Aquatic Acute 1
Aquatic Chronic 1
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
601-008-00-2
204-608-9
123-19-3
Flam. Liq. 3
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
606-027-00-X
203-388-1
106-35-4
Flam. Liq. 3
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
606-003-00-9
203-767-1
110-43-0
Flam. Liq. 3
Acute Tox. 4
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
606-024-00-3
213-831-0
1024-57-3
Carc. 2
Acute Tox. 3
STOT RE 2
Aquatic Acute 1
Aquatic Chronic 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
602-063-00-5
200-962-3
76-44-8
Carc. 2
Acute Tox. 3
STOT RE 2
Aquatic Acute 1
Aquatic Chronic 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
602-046-00-2
-
12035-71-1
Carc. 1A
Muta. 2
Acute Tox. 3
STOT RE 1
Skin Sens. 1
Aquatic Acute 1
Aquatic Chronic 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
028-007-00-4
HALOXYFOP ETHOXYETHYL EST
402-560-5
87237-48-7
Acute Tox. 4
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-207-00-0
600-130-3
100784-20-1
Repr. 1B
Aquatic Acute 1
Aquatic Chronic 1
HP10 Toxic for reproduction: waste which has adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
613-329-00-5
TILCOM HTB
411-740-2
22411-22-9
Eye Dam. 1
Skin Sens. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
072-001-00-4
620-427-1
108173-90-6
Acute Tox. 2
Acute Tox. 4
STOT SE 3
Skin Irrit. 2
Eye Dam. 1
Aquatic Acute 1
Aquatic Chronic 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
612-087-00-8
200-002-3
50-01-1
Acute Tox. 4
Skin Irrit. 2
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
607-148-00-0
GUANIDINIUMBENZOAT
429-820-0
26739-54-8
Acute Tox. 4
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
607-604-00-9
201-964-7
90-05-1
Acute Tox. 4
Skin Irrit. 2
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
604-031-00-6
231-159-6
7440-50-8
Aquatic Chronic 2
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
029-024-00-X
219-468-4
2439-99-8
Eye Dam. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
015-125-00-6
617-243-9
81591-81-3
Acute Tox. 4
Aquatic Chronic 2
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-316-00-3
213-997-4
1071-83-6
Eye Dam. 1
Aquatic Chronic 2
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-315-00-8
206-058-5
298-12-4
Eye Dam. 1
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
607-745-00-6
203-474-9
107-22-2
Muta. 2
Acute Tox. 4
Skin Irrit. 2
Skin Sens. 1
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
605-016-00-7
1 - 2.5 moles ethoxylated
500-045-0
26027-38-3
Aquatic Acute 1
Aquatic Chronic 1
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
604-100-00-0
200-240-8
55-63-0
Acute Tox. 2
Acute Tox. 1
STOT RE 2
Aquatic Chronic 2
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
603-034-00-X
200-240-8
55-63-0
Expl. 1.1
Acute Tox. 2
Acute Tox. 1
STOT RE 2
Aquatic Chronic 2
HP1 Explosive: waste which is capable by chemical reaction of producing gas at such a temperature and pressure and at such a speed as to cause damage to the surroundings. Pyrotechnic waste, explosive organic peroxide waste and explosive self-reactive waste is included.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
603-034-01-7
203-856-5
111-30-8
Acute Tox. 2
Acute Tox. 3
STOT SE 3
Skin Corr. 1B
Resp. Sens. 1
Aquatic Acute 1
Aquatic Chronic 2
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
605-022-00-X
EW 400; GLUCOPROTAMIN
403-950-8
164907-72-6
Acute Tox. 2
Acute Tox. 4
Skin Corr. 1B
Aquatic Acute 1
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP8 Corrosive: waste which on application can cause skin corrosion.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
607-216-00-X
278-636-5
77182-82-2
Repr. 1B
Acute Tox. 4
STOT RE 2
HP10 Toxic for reproduction: waste which has adverse effects on sexual function and fertility in adult males and females, as well as developmental toxicity in the offspring.
HP6 Acute Toxicity: waste which can cause acute toxic effects following oral or dermal administration, or inhalation exposure.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
015-155-00-X
232-589-7
9001-22-3
Resp. Sens. 1
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
647-001-00-8
-
-
Carc. 2
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
014-047-00-X
203-377-1
106-24-1
Skin Sens. 1
HP13 Sensitising: waste which contains one or more substances known to cause sensitising effects to the skin or the respiratory organs.
603-241-00-5
A complex combination of hydrocarbons consisting primarily of paraffins, cycloparaffins, aromatic and olefinic hydrocarbons having carbon numbers predominantly greater than C3 and boiling in the range of 30°C to 260°C (86°F to 500°F).
289-220-8
86290-81-5
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-378-00-4
A complex combination of hydrocarbons separated from the gases from vapor recovery systems by cooling. It consists of hydrocarbons having carbon numbers predominantly in the range of C4 through C11 and boiling in the range of approximately -20°C to 196°C(-4°F to 384°F).
271-025-4
68514-15-8
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-269-00-1
A complex combination of hydrocarbons produced from the topping plant by the distillation of crude oil. It boils in the range of approximately 36.1°C to 193.3°C (97°F to 380°F).
271-727-0
68606-11-1
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-270-00-7
A distillation fraction from the hydrogenation of pyrolysis gasoline boiling in the range of approximately 20°C to 200°C (68°F to 392°F).
302-639-3
94114-03-1
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-389-00-4
A complex combination of hydrocarbons obtained from the fractionation of depropanizer bottoms. It consists of hydrocarbons having carbon numbers predominantly greater than C5.
271-726-5
68606-10-0
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-373-00-7
A complex combination of hydrocarbons separated from natural gas by processes such as refrigeration or absorption. It consists predominantly of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C4 through C8 and boiling in the range of approximately minus 20°C to 120°C (-4°F to 248°F).
232-349-1
8006-61-9
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-261-00-8
Motor fuel produced by the reforming of the refined naphtha fraction of the products of hydrocracking of coal extract or solution produced by the liquid solvent extraction or supercritical gas extraction processes and boiling in the range of approximately 30°C to 180°C (86°F to 356°F). Composed primarily of aromatic and naphthenic hydrocarbons, their alkyl derivatives and alkyl hydrocarbons having carbon numbers in the range of C4 through C9.
302-691-7
94114-55-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
648-151-00-7
A complex high octane combination of hydrocarbons obtained by the catalytic dehydrogenation of a predominantly naphthenic naphtha. It consists predominantly of aromatics and non-aromatics having carbon numbers predominantly in the range of C5 through C11 and boiling in the range of approximately 45°C to 185°C (113°F to 365°F).
297-458-9
93572-29-3
Carc. 1B
Muta. 1B
Asp. Tox. 1
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
HP5 Specific Target Organ Toxicity (STOT)/Aspiration Toxicity: waste which can cause specific target organ toxicity either from a single or repeated exposure, or which cause acute toxic effects following aspiration.
649-312-00-4
A complex combination of hydrocarbons produced by the atmospheric distillation of a butane-butylene stream. It consists of aliphatic hydrocarbons having carbon numbers predominantly in the range of C3 through C4.
270-769-7
68477-87-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-070-00-X
A complex combination of hydrocarbons produced by the fractionation of the charge to the C3-C4 splitter. It consists predominantly of C3 hydrocarbons.
272-893-7
68919-20-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-105-00-9
A complex combination of hydrocarbons produced by the distillation of products from a thermal cracking process. It consists of hydrocarbons having a carbon number predominantly of C4.
273-265-5
68955-28-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-111-00-1
A combination of hydrogen and methane obtained by fractionation of the products from the unifiner unit.
272-885-3
68919-12-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-164-00-0
A complex combination produced by distillation of products from a thermal cracking process. It consists of hydrogen, hydrogen sulfide, carbon monoxide, carbon dioxide and hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-789-6
68478-05-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-139-00-4
A complex combination obtained by the fractionation of reduced crude oil. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
272-884-8
68919-11-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-163-00-5
A complex combination of hydrocarbons obtained from the fractionation of the liquid from the first tower used in the distillation of crude oil. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
272-883-2
68919-10-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-106-00-4
A complex combination of hydrocarbons obtained by the catalytic reforming of straight-run naphtha and fractionation of the total effluent. It consists of methane, ethane, and propane.
272-882-7
68919-09-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-104-00-3
A complex combination of hydrocarbons obtained by the catalytic reforming of straight-run naphtha and the fractionation of the total effluent. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C4.
273-270-2
68955-34-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-112-00-7
A complex combination of hydrocarbons produced by the distillation of products from a steam cracking process. It consists predominantly of propylene with some propane and boils in the range of approximately minus 70°C to 0°C (minus 94°F to 32°F).
295-404-9
92045-22-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-115-00-3
A complex combination obtained by the fractionation of products from the fluidized catalytic cracker and gas oil desulfurizer. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
273-269-7
68955-33-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-167-00-7
A complex combination produced by the fractionation of the overhead products from the catalytic cracking process in the fluidized catalytic cracker. It consists of hydrogen, nitrogen, and hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
271-625-6
68602-84-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-150-00-4
A complex combination obtained from viscosity reduction of residues in a furnace. It consists predominantly of hydrogen sulfide and paraffinic and olefinic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
295-402-8
92045-20-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-174-00-5
A complex combination obtained from the reforming hydrotreating process. It consists primarily of hydrogen, methane, and ethane with various small amounts of hydrogen sulfide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C3 through C5.
270-785-4
68478-02-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-136-00-8
A complex combination obtained from the reforming hydrotreating process. It consists primarily of hydrogen and methane with various small amounts of carbon monoxide, carbon dioxide, nitrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C5.
270-787-5
68478-03-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-137-00-3
A complex combination obtained from the reforming hydrotreating process. It consists primarily of hydrogen with various small amounts of carbon monoxide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-788-0
68478-04-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-138-00-9
A complex combination obtained from the reformers. It consists primarily of hydrogen with various small amounts of carbon monoxide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-784-9
68478-01-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-135-00-2
A complex combination produced by low-pressure flashing of the effluent from the reforming reactor. It consists primarily of hydrogen with various small amounts of methane, ethane, and propane.
271-005-5
68513-19-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-147-00-8
A complex combination produced by the high-pressure flashing of the effluent from the reforming reactor. It consists primarily of hydrogen with various small amounts of methane, ethane, and propane.
271-003-4
68513-18-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-146-00-2
A complex combination obtained from various petroleum refining operations. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
272-338-9
68814-67-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-153-00-0
A complex combination obtained from various refinery processes. It consists of hydrogen, hydrogen sulfide and hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-183-7
68783-07-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-097-00-7
A complex combination obtained from recycled reactor gases. It consists primarily of hydrogen with various small amounts of carbon monoxide, carbon dioxide, nitrogen, hydrogen sulfide, and saturated aliphatic hydrocarbons having carbon numbers in the range of C1 through C5.
270-783-3
68478-00-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-134-00-7
A complex combination produced from the first tower used in the distillation of crude oil. It consists of nitrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-881-1
68919-08-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-162-00-X
A complex combination obtained by the fractionation of the light ends of the platinum reactors of the platformer unit. It consists of hydrogen, methane, ethane, and propane.
272-880-6
68919-07-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-161-00-4
A complex combination obtained from the chemical reforming of naphthenes to aromatics. It consists of hydrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C4.
272-343-6
68814-90-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-154-00-6
A complex combination separated by distillation of a gas stream containing hydrogen, carbon monoxide, carbon dioxide and hydrocarbons having carbon numbers in the range of C1 through C6 or obtained by cracking ethane and propane. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C2, hydrogen, nitrogen, and carbon monoxide.
271-258-1
68527-15-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-148-00-3
A complex combination of hydrocarbons produced by a naphtha unifiner desulfurization process and stripped from the naphtha product. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
272-879-0
68919-06-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-103-00-8
A complex combination obtained as a mixture of the non-condensable portions from the product of a naphtha steam cracking process as well as residual gases obtained during the preparation of subsequent products. It consists predominantly of hydrogen and paraffinic and olefinic hydrocarbons having carbon numbers predominantly in the range of C1 through C5 with which natural gas may also be mixed.
295-401-2
92045-19-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-173-00-X
A complex combination of hydrocarbons obtained by the stabilization of light straight-run naphtha. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C6.
271-002-9
68513-17-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-086-00-7
A complex combination of hydrocarbons obtained by the fractionation of light straight-run gasoline. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-878-5
68919-05-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-102-00-2
270-782-8
68477-99-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-075-00-7
A complex combination obtained from recycled hydrotreated blend oil. It consists primarily of hydrogen and nitrogen with various small amounts of carbon monoxide, carbon dioxide and hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-781-2
68477-98-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-133-00-1
A complex combination obtained from the flash drum of the unit treating sour kerosine with hydrogen in the presence of a catalyst. It consists primarily of hydrogen and methane with various small amounts of nitrogen, carbon monoxide, and hydrocarbons having carbon numbers predominantly in the range of C2 through C5.
272-776-0
68911-59-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-156-00-7
The complex combination obtained from the depentanizer stabilization of hydrotreated kerosine. It consists primarily of hydrogen, methane, ethane, and propane with various small amounts of nitrogen, hydrogen sulfide, carbon monoxide and hydrocarbons having carbon numbers predominantly in the range of C4 through C5.
272-775-5
68911-58-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-155-00-1
A complex combination of gases obtained from flash of the effluents after the hydrogenation reaction. It consists predominantly of hydrogen and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
295-400-7
92045-18-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-172-00-4
A complex combination separated as a gas from hydrocarbon gases by chilling. It consists primarily of hydrogen with various small amounts of carbon monoxide, nitrogen, methane, and C2 hydrocarbons.
270-780-7
68477-97-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-132-00-6
A complex combination obtained by absorbing hydrogen from a hydrogen rich stream. It consists of hydrogen, carbon monoxide, nitrogen, and methane with small amounts of C2 hydrocarbons.
270-779-1
68477-96-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-131-00-0
A complex combination obtained by the liquid-vapor separation of the hydrocracking process reactor effluent. It consists predominantly of hydrogen and saturated hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
272-182-1
68783-06-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-152-00-5
A complex combination of hydrocarbon produced by the distillation of products from a hydrocracking process. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4. It may also contain small amounts of hydrogen and hydrogen sulfide.
271-001-3
68513-16-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-085-00-1
A complex combination stripped from the liquid product of the heavy distillate hydrotreater desulfurization process. It consists of hydrogen, hydrogen sulfide, and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-876-4
68919-04-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-160-00-9
A complex combination of hydrocarbons that is used as the feed into the Girbatol unit to remove hydrogen sulfide. It consists of aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C4.
270-778-6
68477-95-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-074-00-1
A complex combination of hydrocarbons obtained by fractionation of miscellaneous hydrocarbon streams. It consists predominantly of hydrocarbons having carbon numbers in the range of C1 through C4, predominantly propane.
270-777-0
68477-94-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-073-00-6
A complex combination of gases obtained from the reformer and from the purges from the hydrogenation reactor. It consists predominantly of hydrogen and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
295-399-3
92045-17-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-171-00-9
A complex combination obtained by separation of the liquid phase from the effluent from the hydrogenation reaction. It consists predominantly of hydrogen, hydrogen sulfide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
295-398-8
92045-16-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-170-00-3
A complex combination produced by desulfurization of gas oils with diethanolamine. It consists predominantly of hydrogen sulfide, hydrogen and aliphatic hydrocarbons having carbon numbers in the range of C1 through C5.
295-397-2
92045-15-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-169-00-8
A complex combination of hydrocarbons produced by distillation of products from combined gas streams in a gas concentration reabsorber. It consists predominantly of hydrogen, carbon monoxide, carbon dioxide, nitrogen, hydrogen sulfide and hydrocarbons having carbon numbers in the range of C1 through C3.
270-776-5
68477-93-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-130-00-5
A complex combination of hydrocarbons obtained by the fractionation of the full-range straight-run naphtha. It consists of hydrocarbons having carbon numbers predominantly in the range of C2 through C6.
271-000-8
68513-15-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-084-00-6
A complex combination produced by scrubbing the overhead gas from the fluidized catalytic cracker. It consists of hydrogen, nitrogen, methane, ethane and propane.
272-875-9
68919-03-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-159-00-3
A complex combination produced by the fractionation of the overhead product of the fluidized catalytic cracking process. It consists of hydrogen, hydrogen sulfide, nitrogen, and hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-874-3
68919-02-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-158-00-8
The complex combination of dry gases from a gas concentration unit. It consists of hydrogen, hydrogen sulfide and hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
270-774-4
68477-92-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-129-00-X
A complex combination stripped from the liquid product of the unifiner desulfurization process. It consists of hydrogen sulfide, methane, ethane, and propane.
272-873-8
68919-01-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-157-00-2
A complex combination of hydrocarbons produced by distillation of products from the gas and gasoline fractions of a catalytic cracking process. It consists of aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C4.
270-773-9
68477-91-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-072-00-0
A complex combination of hydrocarbons produced by the distillation of products from the gas and gasoline fractions of a catalytic cracking process. It consists predominantly of propylene with some ethane and propane.
270-772-3
68477-90-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-071-00-5
A complex combination of hydrocarbons obtained from the fractionation of depropanizer bottoms. It consists predominantly of butane, isobutane and butadiene.
271-742-2
68606-34-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-096-00-1
A complex combination of hydrocarbons obtained by the fractionation of combined naphtha streams. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-872-2
68919-00-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-101-00-7
A complex combination of hydrocarbons produced from distillation of the gas and gasoline fractions from the catalytic cracking process. It contains predominantly ethane and ethylene.
270-768-1
68477-86-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-069-00-4
A complex combination of hydrocarbons produced by the fractionation of crude oil. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-871-7
68918-99-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-100-00-1
A complex combination produced by crude distillation and catalytic cracking processes. It consists of hydrogen, hydrogen sulfide, nitrogen, carbon monoxide and paraffinic and olefinic hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
273-563-5
68989-88-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-168-00-2
A complex combination of hydrocarbons obtained from the stabilization of catalytic cracked naphtha. It consists of aliphatic hydrocarbons having carbon numbers predominantly in the range of C3 through C5.
270-754-5
68477-72-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-209-00-4
A complex combination of hydrocarbons obtained from fractionation of catalytic cracked gas oil hydrocarbon stream and treated to remove hydrogen sulfide and other acidic components. It consists of hydrocarbons having carbon numbers in the range of C3 through C5, predominantly C4.
270-752-4
68477-71-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-208-00-9
A complex combination of hydrocarbons produced by distillation of products from a catalytic reforming process. It consists of hydrocarbons having carbon numbers in the range of C1 through C6, predominantly C1 through C4.
270-760-8
68477-79-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-066-00-8
A complex combination of hydrocarbons obtained from the catalytic reforming of straight-run naphtha followed by fractionation of the total effluent. It consists of hydrogen, methane, ethane and propane.
270-999-8
68513-14-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-145-00-7
A complex combination of hydrocarbons obtained from the stabilization of catalytic reformed naphtha. Its consists of hydrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
270-759-2
68477-77-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-124-00-2
A complex combination of hydrocarbons obtained from the fractionation stabilization of catalytic polymerized naphtha. It consists of aliphatic hydrocarbons having carbon numbers in the range of C2 through C6, predominantly C2 through C4.
270-758-7
68477-76-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-065-00-2
A complex combination of hydrocarbons produced by the distillation of the products from a catalytic cracking process. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C3 through C5.
272-203-4
68783-64-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-098-00-2
A complex combination of hydrocarbons produced by the distillation of the products from a catalytic cracking process. It consists predominantly of aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-756-6
68477-74-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-063-00-1
A complex combination of hydrocarbons produced by the distillation of products from a catalytic cracking process. It consists of aliphatic hydrocarbons having carbon numbers in the range of C1 through C6, predominantly C1 through C5.
270-757-1
68477-75-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-064-00-7
A complex combination of hydrocarbons produced by the distillation of products from the catalytic cracking process. It consists of hydrocarbons having carbon numbers predominantly in the range of C3 through C5 and boiling in the range of approximately -48°C to 32°C (-54°F to 90°F).
270-071-2
68409-99-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-191-00-8
A complex combination of hydrocarbons obtained from fractionation of catalytic cracked hydrocarbons and treated to remove acidic impurities. It consists of hydrocarbons having carbon numbers in the range of C2 through C4, predominantly C3.
270-755-0
68477-73-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-062-00-6
A complex combination of hydrocarbons obtained from fractionation of catalytic cracked naphtha. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
273-169-3
68952-76-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-107-00-X
A complex combination of hydrocarbons produced by distillation of products from catalytic reforming of C6-C8 feed. It consists of hydrocarbons having carbon numbers in the range of C1 through C5 and hydrogen.
270-762-9
68477-81-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-126-00-3
A complex combination of hydrocarbons produced by distillation of products from catalytic reforming of C6-C8 feed and recycled to conserve hydrogen. It consists primarily of hydrogen. It may also contain various small amounts of carbon monoxide, carbon dioxide, nitrogen, and hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-761-3
68477-80-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-125-00-8
270-763-4
68477-82-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-127-00-9
A complex combination of hydrocarbons produced by distillation of products from a catalytic fractionation process. It consists of aliphatic hydrocarbons having carbon numbers in the range of C3 through C5, predominantly C4.
270-767-6
68477-85-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-068-00-9
A complex combination of olefinic and paraffinic hydrocarbons having carbon numbers in the range of C3 through C5 which are used as alkylation feed. Ambient temperatures normally exceed the critical temperature of these combinations.
270-765-5
68477-83-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-067-00-3
A complex combination of hydrocarbons produced by distillation of products from the cracking of crude oil. It consists of hydrocarbons having carbon numbers in the range of C3 through C4, predominantly of propane and propylene, and boiling in the range of approximately -51°C to -1°C (-60°F to 30°F.)
268-629-5
68131-75-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-177-00-1
A complex combination of hydrocarbons from the distillation of saturated and unsaturated hydrocarbons usually ranging in carbon numbers from C3 through C6, predominantly butane and isobutane. It consists of saturated and unsaturated hydrocarbons having carbon numbers in the range of C3 through C4, predominantly isobutane.
270-724-1
68477-33-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-204-00-7
A complex combination of hydrocarbons obtained by the extraction of hydrogen from a gas stream which consists primarily of hydrogen with small amounts of nitrogen, carbon monoxide, methane, ethane, and ethylene. It contains predominantly hydrocarbons such as methane, ethane, and ethylene with small amounts of hydrogen, nitrogen and carbon monoxide.
270-766-0
68477-84-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-128-00-4
A complex combination of hydrocarbons obtained by subjecting a petroleum distillate to a sweetening process to convert mercaptans or to remove acidic impurities. It consists predominantly of saturated and unsaturated hydrocarbons having carbon numbers predominantly in the range of C2 through C4 and boiling in the range of approximately -51°C to -34°C (-60°F to -30°F).
272-205-5
68783-65-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-099-00-8
A complex combination of hydrocarbons produced by the distillation of products from a catalytic fractionation process. It contains predominantly ethane, ethylene, propane, and propylene.
270-751-9
68477-70-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-207-00-3
A complex combination of hydrocarbons produced by the distillation of crude oil and/or the cracking of tower gas oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
271-624-0
68602-83-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-092-00-X
A complex combination of hydrocarbons obtained from the distillation of the butane stream. It consists of aliphatic hydrocarbons having carbon numbers predominantly in the range of C3 through C4.
270-750-3
68477-69-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-206-00-8
A complex combination of hydrocarbons obtained by distillation of a blend oil. It consists primarily of hydrogen and nitrogen with various small amounts of carbon monoxide, carbon dioxide, and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-749-8
68477-68-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-123-00-7
A complex combination of hydrocarbons obtained by recycling the gases of the benzene unit. It consists primarily of hydrogen with various small amounts of carbon monoxide and hydrocarbons having carbon numbers in the range of C1 through C6.
270-748-2
68477-67-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-122-00-1
A complex combination produced by treating the feed from the benzene unit with hydrogen in the presence of a catalyst followed by depentanizing. It consists primarily of hydrogen, ethane and propane with various small amounts of nitrogen, carbon monoxide, carbon dioxide and hydrocarbons having carbon numbers predominantly in the range of C1 through C6. It may contain trace amounts of benzene.
271-623-5
68602-82-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-149-00-9

Export search results to: