Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-05-04 to 2015-05-05
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
adopted 27 July 1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
dated 30 May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Version / remarks:
dated August 1996
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Key result
Type:
relative density
Density:
0.938 other: dimensionless
Temp.:
20
Remarks on result:
other: with respect to water at 4 °C
Key result
Type:
density
Density:
0.938 g/cm³
Temp.:
20 °C

Calibration of the pycnometer

Measured data

Empty pycnometer, g

Pycnometer with water, g

1

45.61182

96.0325

2

45.60977

96.0330

3

45.61048

96.0402

4

45.61001

96.0331

5

45.61173

96.0336

Density of water at 20 °C, g/cm3:

0.99823

 

Volume of pycnometer, cm3:

50.5131

 

 

Density of the test item

 

Empty pycnometer, g

Pycnometer with test item, g

Test item in the pycnometer, g

Density of the test item, g/cm3

45.61061

93.0130

47.40239

0.9384

45.61149

93.0076

47.39611

0.9383

45.61016

93.0139

47.40374

0.9384

45.61110

92.9952

47.38410

0.9381

45.60978

93.0110

47.40122

0.9384

Mean:

0.9383

Confidence int.(95%):

0.00020

RSD (CV%):

0.017

 

Conclusions:
The relative density of SIKA Hardener LTJ was determined to be 0.9383 ± 0.00020 at 20 °C ± 0.2 °C with respect to water at 4 °C.
Executive summary:

A study was conducted according to OECD TG 110, Regulation (EC) No 440/2008 method A.3 and OPPTS 830.7300 to determine the relative density of SIKA Hardener LTJ. The density was determined in six independent determinations. Using the pycnometer method the density was determined to be 0.9383 ± 0.00020 g/cm3 at 20 ± 0.5 °C and the relative density 0.9383 with respect to water at 4 °C respectively. The standard deviation reflects the distinguished correlation of the individual determinations. No observations were made which cause doubt on the validity of the outcome of the study.

Description of key information


The relative density of the test item was determined to be 0.9383 ± 0.00020 at 20 °C ± 0.2 °C with respect to water at 4 °C.


 


Key value for chemical safety assessment

Relative density at 20C:
0.938

Additional information

A study was conducted according to OECD TG 110, Regulation (EC) No 440/2008 method A.3 and OPPTS 830.7300 to determine the relative density of the test item. The density was determined in six independent determinations. Using the pycnometer method the density was determined to be 0.9383 ± 0.00020 g/cm3 at 20 ± 0.5 °C and the relative density 0.9383 with respect to water at 4 °C respectively. The standard deviation reflects the distinguished correlation of the individual determinations. No observations were made which cause doubt on the validity of the outcome of the study: