Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19. Oct. 2006 - 20. Oct. 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP and Guideline conform

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
resp. ISO 13317-2
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Landesamt für Umweltschutz und Gewerbeaufsicht, Rheinland-Pfalz
Type of distribution:
other: fixed pipette method

Test material

Constituent 1
Chemical structure
Reference substance name:
Silicic acid, titanium salt
EC Number:
255-911-8
EC Name:
Silicic acid, titanium salt
Cas Number:
42613-21-8
Molecular formula:
TiSixOy, where x and y are unspecified.
IUPAC Name:
titanium(4+) bis(oxosilanebis(olate))
Details on test material:
- Name of test material (as cited in study report): Magnapore 963
- Physical state/appearance: black powder
- Analytical purity: 98%
- Lot/batch No.: LOT 405
- Expiration date of the lot/batch: 01.09.2007
- Production date: 01.03.2006
- Storage condition of test material: room temperature, keep dry
- Homogeneity: homogenous
- Additive: Chromium (III) hydroxide, CAS No. 1308-14-1

Results and discussion

Particle size
Percentile:
D50
Mean:
25 - 80 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
200.72 µm
Distribution:
97.95 %
No.:
#2
Size:
80.67 µm
Distribution:
82.46 %
No.:
#3
Size:
56.05 µm
Distribution:
55.47 %
No.:
#4
Size:
34.86 µm
Distribution:
28.99 %
No.:
#5
Size:
27.16 µm
Distribution:
11.99 %
No.:
#6
Size:
18.84 µm
Distribution:
4 %
No.:
#7
Size:
13.08 µm
Distribution:
1.5 %
No.:
#8
Size:
9.08 µm
Distribution:
0 %

Any other information on results incl. tables

All measured values show good reproducibility, giving deviations of less than 2%.

The particle size distribution shows no single peaks, but a continuous distribution roughly between 25 and 80 µm, leaving fractions of less than 20% above 80 µm and less than 10% below 25 µm.

Applicant's summary and conclusion