Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 202-709-2 | CAS number: 98-87-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
- Endpoint:
- toxicity to microorganisms
- Type of information:
- experimental study
- Adequacy of study:
- other information
- Reliability:
- 4 (not assignable)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- The authors tested the toxicity to micro-organisms of benzal chloride using a methodology described by Krebbs (1983). GLP standards are not specified and very few data are given concerning the materials and methods and the results. Thus the study is considered as not assignable, such a Klimisch 4e, since the documentation is insufficient for assessment.
Data source
Reference
- Reference Type:
- publication
- Title:
- Versuche zur biologischen Abbaubarkeit chlororganischer Verbindungen
- Author:
- Steinhäuser K.G., Amann W. and Polenz A.
- Year:
- 1 986
- Bibliographic source:
- Vom Wasser, 67: 147-154
Materials and methods
- Principles of method if other than guideline:
- Krebs F. (1983) Toxizitätstest mit gefriergetrockneten Leuchtbakterien. Gewässerschutz, Wasser, Abwasser 63: 173-230
- GLP compliance:
- not specified
Test material
- Reference substance name:
- α,α-dichlorotoluene
- EC Number:
- 202-709-2
- EC Name:
- α,α-dichlorotoluene
- Cas Number:
- 98-87-3
- Molecular formula:
- C7H6Cl2
- IUPAC Name:
- (dichloromethyl)benzene
- Reference substance name:
- Dichloromethylbenzene
- EC Number:
- 249-854-8
- EC Name:
- Dichloromethylbenzene
- Cas Number:
- 29797-40-8
- IUPAC Name:
- (dichloromethyl)benzene
- Details on test material:
- - Name of test material (as cited in study report): Benzylidenchlorid
No more data available
Constituent 1
Constituent 2
Sampling and analysis
- Analytical monitoring:
- not specified
Test solutions
- Vehicle:
- not specified
Test organisms
- Test organisms (species):
- Photobacterium phosphoreum
Study design
- Test type:
- static
- Water media type:
- not specified
- Limit test:
- no
- Total exposure duration:
- 30 min
Results and discussion
Effect concentrations
- Duration:
- 30 min
- Dose descriptor:
- EC50
- Effect conc.:
- 32 mg/L
- Nominal / measured:
- not specified
- Conc. based on:
- test mat.
- Basis for effect:
- other: bioluminescence
Applicant's summary and conclusion
- Validity criteria fulfilled:
- not applicable
- Conclusions:
- The authors tested the toxicity of benzal chloride using a methodology described by Krebbs (1983). Under these test conditions the EC50 for Photobacterium phosphoreum was assessed to be 32 mg/L.
- Executive summary:
The authors tested the toxicity of benzalchloride using a methodology described by Krebbs (1983). Photobacterium phosphoreum was exposed to the test substance and after 30 min of exposure bioluminescence was measured using a Beckman-Microtox-photometer. The EC50 was assessed to be 32 mg/L. No further details on the materials and methods and on the results are available.
GLP standards are not specified and very few data are given concerning materials and methodology and results. Thus the study is considered not assignable due to insufficient data for assessment.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.