Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 217-803-9 | CAS number: 1962-75-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Short-term toxicity to aquatic invertebrates
Administrative data
- Endpoint:
- short-term toxicity to aquatic invertebrates
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Guideline study conducted under GLP
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 005
- Report date:
- 2005
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 202 (Daphnia sp. Acute Immobilisation Test)
- Deviations:
- no
- GLP compliance:
- yes
Test material
- Reference substance name:
- Dibutyl terephthalate
- EC Number:
- 217-803-9
- EC Name:
- Dibutyl terephthalate
- Cas Number:
- 1962-75-0
- Molecular formula:
- C16H22O4
- IUPAC Name:
- 1,4-dibutyl benzene-1,4-dicarboxylate
- Details on test material:
- - Name of test material (as cited in study report): Dibutyl terephthalate
- Substance type: production sample
- Physical state: clear liquid
- Analytical purity: 98.7%
- Lot/batch No.: X-29455-010
Constituent 1
Sampling and analysis
- Analytical monitoring:
- yes
- Details on sampling:
- Samples of the control and test substance exposure solutions were analyzed at test start and test end to verify test substance concentration. The samples analyzed at test start were collccted from approximately mid-depth of the 22-L mixing vessels using a spigot-valve assembly. The samples analyzed at test end were surrogate exposure solutions collected at test start that were stoppered without headspace throughout the study. Samples were analyzed using gas chromatography with flame ionization detection (GC/FID).
Test solutions
- Vehicle:
- yes
- Details on test solutions:
- The solubility of the substance in the test medium was measured by the analytical laboratory. The solubility of the substance was determined to be 0.13 mg/L. Exposure solutions containing the substance at nominal concentrations of 0.025, 0.05, 0.1, 0.2, and 0.4 mg/L were tested. The exposure solutions were prepared by direct addition of a stock solution containing the substance to dilution water. Five stock solutions were prepared at nominal concentrations of 0.26,0.56, 1.1, 2.1, and 4.1 mg/mL by weighing the appropriate amounts of substance into volumetric flasks that were brought to volume with a solvent, N,N-Dimethylformamide (DMF). The stocks were sonicated and inverted several times to dissolve the substance, then 2 mL of each stock solution were added to 22-L vessels containing 20 liters of laboratory dilution water. Dilution water and carrier solvent control solutions were also prepared. Carrier solvent controls were prepared by pipetting 2 mL ofDMF into 20 liters of laboratory dilution water. The solutions were stirred with stir bars and stir plates for approximately 3 hours.
Test organisms
- Test organisms (species):
- Daphnia magna
- Details on test organisms:
- Daphnia magna organisms were cultured within the testing facility. An organism origination statement and taxonomic verification are located in a central file maintained by the Ecotoxicology Group, Room 2020, Building 320, Kodak Park. The test organisms are cultured in 100-L stainless steel tanks provided with a continuous flow of filtered-treated-tempered water. The water depth is maintained by use of an ovelflow pipe that discharges into a floor drain. The tanks are continuously aerated by passing oil-free filtered air through air stones. The culturing facility is maintained at a constant temperature of 20±1°C and is illuminated with fluorescent lighting for 16 hours followed by a 30-minute transition period leading to 8 hours of darkness. The daphnids are fed an ample amount of a spinach-yeast-fish food slurry that may be supplemented with a yeast-Cerophyll leaves-trout chow (YCT) mixture or green algae, such as Selenastrum capricomutum. The dietary components of the YCT are analyzed routinely to identify contaminants that could interfere with the outcome of the study. The brood stock used in this test were cultured in the water used for preparing the test substance
solutions. Approximately 24 hours before test start an ample number of gravid adult daphnids were transferred into 20-cm diameter bowls, containing laboratory culture water, and fed. The neonates produced in the following 24-hour period were used as the test organisms. The neonates were collected by pipette and transferred dircctly into the test vessels. Sequential randomization was accomplished by allocating to each vessel no more than 50% of anyone set of test organisms at a time.
Study design
- Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 48 h
Test conditions
- Test temperature:
- The temperature of the dilution water and carier solvent control solutions ranged from 19.6 to 20.4°C. The temperature of the test substance solutions ranged from 20.1 to 20.5°C.
- pH:
- The pH of the control and test substance solutions ranged from 8.0 to 8.3.
- Dissolved oxygen:
- The dissolved oxygen concentrations of the control solutions ranged from 7.9 to 9.2 mg/L, and the test substance solutions
ranged from 8.2 to 9.1 mg/L. - Nominal and measured concentrations:
- The combined replicate exposure concentrations of the nominally prepared 0.025, 0.05, 0.1, 0.2 and 0.4-mg/L solutions were calculated to be 0.02, 0.04, 0.08, 0.16, and 0.34 mg/L. The loss of test substance concentration from the individual replicates ranged from 30.4% to -13.3% during the 48-hour exposure.
- Details on test conditions:
- The test was performed as a 48-hour static exposure. The exposure solutions were maintained at a temperature of 20 ± 1°C and illuminated with fluorescent lighting for 16 hours followed by a 30-minute transition period leading to 8 hours of darkness. The test vessels were 300-mL pyrex BOD bottles containing 300 mL of test solution with no headspace. The test vessels were stoppered during the study. They were not cleaned or aerated, nor were the test organisms fed. Two replicates were prepared for each exposure. At test start, the exposure solutions were prepared and transferred into their respective test vessels. The physical parameters of the solutions were measured and ten test organisms were introduced into each replicate. Observations for mobility and stress were made at test start and after 4, 24, and 48 hours of exposure. The appearances of the exposure solutions were observed and recorded at test start, after 4 hours of exposure, and at the end of each 24-hour period. The physical parameters of each exposure solution were measured again at test end.
Results and discussion
Effect concentrationsopen allclose all
- Duration:
- 48 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 0.34 mg/L
- Nominal / measured:
- meas. (not specified)
- Conc. based on:
- test mat.
- Basis for effect:
- mobility
- Duration:
- 48 h
- Dose descriptor:
- NOEC
- Effect conc.:
- >= 0.16 mg/L
- Nominal / measured:
- meas. (not specified)
- Conc. based on:
- test mat.
- Basis for effect:
- mobility
- Details on results:
- No organisms were adversely affected in the dilution water or carrier solvent controls, or in the 0.025 and 0.1-mg/L solutions. In the 0.05 and 0.2 mg/L solutions 5% immobility was observed. In the 0.4-mg/L solutions six organisms were immobile and one organism was not found and assumed to be immobile. Statistical analyses of the study data were performed using the TOXSTAT statistical software. All data were used in the statistical analyses. For the purpose of calculating or estimating the 48-hour EC50 value, immobility served as the requisite endpoint. The 48-hour EC50 value
was estimated by extrapolation to be 0.41 mg/L. However, since this exceeds the highest measured concentration the EC50 is reported here as > the highest measured concentration (0.34 mg/L). The highest tested concentration resulting in < or =10% immobility (NOEC) was determined to be > or = 0.16 mg/L. The results indicate that the 48-hour EC50 and NOEC values are greater than the measured aqueous solubility of the test substance. - Reported statistics and error estimates:
- Probit EC50 95% confidence limits = 0.2923 to 0.5184
NOEC determined using Fisher's Exact Test (alpha level = 0.05)
Applicant's summary and conclusion
- Validity criteria fulfilled:
- yes
- Conclusions:
- Well conducted guideline study conducted under GLP.
- Executive summary:
Daphnia magna were exposed to five concentrations of the test substance in a 48-hour, static, aquatic effects test. The solubility of the substance in the test medium was investigated and determined to be 0.13 mg/L. Exposure solutions containing the substance at nominal concentrations of 0.025, 0.05, 0.1, 0.2, and 0.4 mg/L were tested. The concentrations of test substance in the exposure solutions were analytically verified during the study. The average concentrations of the prepared solutions were calculated to be 0.02, 0.04, 0.08, 0.16. and 0.34 mg/L. The 48-hour EC50 value was estimated to be 0.41 mg/L by extrapolation. However, since this exceeds the highest measured concentration the EC50 is reported here as greater than the highest measured concentration (48 h EC50 >0.34 mg/L). The highest tested concentration resulting in < or =10% immobility (NOEC) was determined to be > or = 0.16 mg/L. The results indicate that the 48-hour EC50 and NOEC values are greater than the measured aqueous solubility of the test substance.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.