Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 218-089-1 | CAS number: 2050-46-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
- General advice:
Show the safety data sheet to the doctor in attendance.
First aider needs to protect himself.
Place affected clothing in a sealed bag for subsequent decontamination.
- Following inhalation:
Move to fresh air.
- Following skin contact:
Take off contaminated clothing and shoes immediately.
Wash off with soap and plenty of water.
If skin irritation occurs, seek medical advice/attention.
- Following eye contact:
Rinse with running water whilst keeping the eyes wide open (at least 15 minutes)
If eye irritation persists, consult a specialist.
- Following ingestion:
Do NOT induce vomiting.
Rinse mouth with water.
If symptoms persist, call a physician.
- Most important symptoms and effects:
No data available
Fire-fighting measures
- Suitable extinguishing media:
Water spray
Carbon dioxide (CO2)
Foam
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
- Unsuitable extinguishing media:
High volume water jet
- Special hazards arising from the substance or mixture:
Harmful or toxic vapours are released.
Combustible solid.
Risk of dust explosion.
- Advice for fire fighter:
Special protective equipment for firefighters
Special protective equipment for firefighters
Wear self-contained breathing apparatus for firefighting if necessary.
Self-contained breathing apparatus (EN 133)
Specific fire fighting methods
Use appropriate means for fighting adjacent fires.
Evacuate personnel to safe areas.
Cool containers/tanks with water spray.
Accidental release measures
- Personal precautions, Protective equipment and emergency procedures:
Remove all sources of ignition.
Avoid contact with eyes
Do not breathe vapour.
Personal protective equipment
Wear suitable gloves.
Safety glasses
Boots
Mark the contaminated area with signs and prevent access to unauthorized personnel.
Signal word
Ventilate the area.
- Environmental precautions:
Do not allow uncontrolled discharge of product into the environment.
- Methods and material for containment and cleaning up:
Recovery
Shovel or sweep up.
Avoid dust formation.
Use only non-sparking tools.
Keep in properly labelled containers.
Keep in suitable, closed containers for disposal.
Decontamination/cleaning
Wash off with plenty of water.
Recover the cleaning water for subsequent disposal.
Disposal
Treat recovered material as described in the section "Disposal considerations".
Handling and storage
- Precautions for safe handling:
Ground/bond container and receiving equipment.
Potential dust explosion hazard.
Non-sparking tools should be used.
Dry powders can build static electricity charges when subjected to the friction of transfer and mixing operations.
It is recommended that all dust control equipment such as local exhaust ventilation and material transport systems involved in handling of this product contain explosion relief vents or an explosion suppression system or an oxygen deficient environment.
Avoid dust formation.
Dust must be extracted directly at the point of origin.
- Hygiene measures
- The substance/product is registered with strictly controlled conditions as defined in Article 18(4) of Regulation (EC) No. 1907/2006 (REACH Regulation) and must therefore be handled as such.
- Wash hands before breaks and at the end of workday.
- When using do not eat, drink or smoke.
- Conditions for safe storage, including any incompatibilities:
Technical measures/Storage conditions
The floor of the depot should be impermeable and designed to form a water-tight basin.
Stable under normal conditions.
Keep container tightly closed and dry.
Keep away from open flames, hot surfaces and sources of ignition.
Keep away from: Strong oxidizing agents
Packaging material
Suitable material
Coated steels.
Remarks
Steel drums with an inner lining.
glass bottles
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- not regulated
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- not regulated
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- not regulated
Shipping information
- Proper shipping name and description:
- not regulated
- Chemical name:
- not regulated
- Labels:
- not regulated
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- not regulated
Shipping information
- Proper shipping name and description:
- not regulated
- Chemical name:
- not regulated
- Labels:
- not regulated
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 17(3) for on-site isolated intermediates and, in case the substance is transported to other sites for further processing, the substance should be handled at these sites under the Strictly Controlled Conditions as specified in REACH regulation Article 18(4). Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each manufacturing site.
Written confirmation of application of Strictly Controlled Conditions has been received from every affected Distributor and Downstream Processor/User of the Registrant’s intermediate.
1. Engineering measures
Effective exhaust ventilation system
2. Protection measures
Selection of appropriate personal protective equipment should be based on an evaluation of the performance characteristics of the protective equipment relative to the task(s) to be performed, conditions present, duration of use, and the potential hazards and/or risks that may occur during use.
The protective equipment must be selected in accordance with current local standards and in cooperation with the supplier of the protective equipment.
The protective equipment must be selected in accordance with current CEN standards and in cooperation with the supplier of the protective equipment.
3. Hand protection
Where there is a risk of contact with hands, use appropriate gloves
Gloves must be inspected prior to use.
Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
5. Body protection
Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Remove and wash contaminated clothing.
Wear suitable protective clothing, gloves and eye/face protection.
Remove and wash contaminated clothing before re-use.
6. Eye protection
Safety glasses with side-shields
7. Respiratory protection
Use a respirator with an approved filter if a risk assessment indicates this is necessary.
8. Hygiene measures
The substance/product is registered with strictly controlled conditions as defined in Article 18(4) of Regulation (EC) No. 1907/2006 (REACH Regulation) and must therefore be handled as such.
Wash hands before breaks and at the end of workday.
When using do not eat, drink or smoke.
Stability and reactivity
1. Reactivity
No hazards to be specially mentioned.
2. Chemical stability
Stable at room temperature.
3. Possibility of hazardous reactions
- Hazardous polymerisation does not occur.
4. Conditions to avoid
Heat, flames and sparks.
Static electricity
Avoid dust formation.
5. Incompatible materials
Strong oxidizing agents
6. Hazardous decomposition products
On combustion or on thermal decomposition (pyrolysis) releases:
Toxic Gas
Carbon oxides
Disposal considerations
Product Disposal Prohibition :
Do not dispose of with domestic refuse.
Must be incinerated in a suitable incineration plant holding a permit delivered by the competent authorities.
Advice on cleaning and disposal of packaging
Allow it to drain thoroughly.
Must be incinerated in a suitable incineration plant holding a permit delivered by the competent authorities.
Dispose of in accordance with local regulations.
Measure for waste avoidance or recovery
Do not dispose of with domestic refuse.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.