EC number: 629-348-7 | CAS number: 23357-52-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Description of first aid measures
Immediately remove contaminated clothing.
If inhaled:
If difficulties occur after vapour/aerosol has been inhaled, remove to fresh air and seek medical attention.
On skin contact:
Wash thoroughly with soap and water.
On contact with eyes:
Wash affected eyes for at least 15 minutes under running water with eyelids held open. If irritation develops, seek medical attention.
On ingestion:
Rinse mouth immediately and then drink plenty of water, seek medical attention.
Indication of any immediate medical attention and special treatment needed
Treatment: Medical monitoring for at least 24 hours. Treat according to symptoms (decontamination, vital functions), no known specific antidote, administer corticosteroid dose aerosol to prevent pulmonary odema.
Fire-fighting measures
Extinguishing media
Suitable extinguishing media:
dry powder, foam, water spray
Unsuitable extinguishing media for safety reasons:
carbon dioxide
Special hazards arising from the substance or mixture
carbon monoxide, Carbon dioxide, nitrous gases
Advice for fire-fighters
Special protective equipment:
Wear self-contained breathing apparatus and chemical-protective clothing.
Further information:
Collect contaminated extinguishing water separately, do not allow to reach sewage or effluent systems.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Handle in accordance with good industrial hygiene and safety practice.
Environmental precautions
Do not empty into drains.
Methods and material for containment and cleaning up
For small amounts: Pick up with absorbent material (e.g. sand, sawdust, general-purpose binder).
For large amounts: Pick up with suitable appliance and dispose of.
Clean contaminated floors and objects thoroughly with water and detergents, observing environmental regulations. Collect waste in suitable containers, which can be labeled and sealed. Incinerate or take to a special waste disposal site in accordance with local authority regulations.
Handling and storage
Precautions for safe handling
Ensure thorough ventilation of stores and work areas.
Protection against fire and explosion:
Take precautionary measures against static discharges.
Conditions for safe storage, including any incompatibilities
Segregate from acids and acid forming substances.
Suitable materials for containers: Low density polyethylene (LDPE), Stainless steel 1.4301 (V2), Stainless steel 1.4401, High density polyethylene (HDPE), carbon steel (iron), glass
Further information on storage conditions: Containers should be stored tightly sealed in a dry place. Keep under nitrogen.
Storage stability:
Storage duration: 24 Months
Store at ambient temperature.
From the data on storage duration in this safety data sheet no agreed statement regarding the warrantee of application properties can be deduced.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control parameters
Components with workplace control parameters
No occupational exposure limits known.
Exposure controls
Personal protective equipment
Respiratory protection:
Wear respiratory protection if ventilation is inadequate.
Hand protection:
Suitable chemical resistant safety gloves (EN 374) also with prolonged, direct contact (Recommended: Protective index 6, corresponding > 480 minutes of permeation time according to EN 374): E.g. nitrile rubber (0.4 mm), chloroprene rubber (0.5 mm), butyl rubber (0.7 mm) and other
Manufacturer's directions for use should be observed because of great diversity of types.
Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing.
Eye protection:
Safety glasses with side-shields (frame goggles) (e.g. EN 166)
General safety and hygiene measures
Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work clothing is required additionally to the stated personal protection equipment. Take off immediately all contaminated clothing. Store work clothing separately.
Stability and reactivity
Reactivity
No hazardous reactions if stored and handled as prescribed/indicated.
Corrosion to metals:
Corrosive effects to metal are not anticipated.
Chemical stability
The product is chemically stable.
Possibility of hazardous reactions
Reacts with acids. The progress of reaction is exothermic. Reacts with diisocyanates. Reacts with carbon dioxide.
Conditions to avoid
No special precautions other than good housekeeping of chemicals.
Incompatible materials
Substances to avoid:
acids
Hazardous decomposition products
Hazardous decomposition products:
No hazardous decomposition products if stored and handled as prescribed/indicated.
Disposal considerations
Waste treatment methods
Incinerate in suitable incineration plant, observing local authority regulations.
Contaminated packaging:
Contaminated packaging should be emptied as far as possible; then it can be passed on for recycling after being thoroughly cleaned.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.