Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 211-659-0 | CAS number: 682-01-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Inhalation
If aerosol or mists are formed:
If necessary: Provide with fresh air.
Skin contact
Wash off with plenty of water and soap.
Eye contact
Rinse thoroughly with plenty of water keeping eyelid open.
In case of persistent discomfort: Consult an ophthalmologist.
Ingestion
Have the mouth rinsed with water.
After absorbing large amounts of substance / In case of discomfort: Supply with medical care.
Most important symptoms and effects, both acute and delayed
Symptoms
None known
Hazards
None known
Indication of any immediate medical attention and special treatment needed
After absorbing large amounts of substance:
administration of activated charcoal.
Acceleration of gastrointestinal passage
Fire-fighting measures
Suitable extinguishing media
foam, water spray, CO2, dry powder
Advice for firefighters
Water used to extinguish fire should not enter drainage systems, soil or stretches of water.
Ensure there are sufficient retaining facilities for water used to extinguish fire.
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Wear personal protective equipment.
Keep away from sources of ignition - No smoking.
Environmental precautions
Do not allow substance to enter soil, bodies of water or sewage canals.
Methods and material for containment and cleaning up
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Fill into marked, sealable containers.
To be disposed of in compliance with existing regulations.
Suitable binder: sand (for damming up), sawdust, universal absorbent
Handling and storage
Handling
Precautions for safe handling
Provide good ventilation or extraction.
Advice on protection against fire and explosion
Take precautionary measures against static charges, keep away from sources of ignition.
Storage
Conditions for safe storage, including any incompatibilities
Keep containers tightly closed in a cool, well-ventilated place.
Protect from moisture.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- Not classified as dangerous for conveyance in the meaning of the Carriage of Dangerous Goods by Road and Rail (ADR / RID).
RID
Not classified as dangerous for conveyance in the meaning of the Carriage of Dangerous Goods by Road and Rail (ADR / RID).
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- Not hazardous freight in inland waterway traffic (ADN).
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- Not classified as dangerous for conveyance in the meaning of the Carriage of Dangerous Goods.
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- IATA_C
Not hazardous freight in air traffic (ICAO-TI / IATA-DGR).
IATA_P
Not hazardous freight in air traffic (ICAO-TI / IATA-DGR).
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Engineering measures
Provide good ventilation or extraction.
Personal protective equipment
Respiratory protection
In case of dusts/vapours/aerosols being formed or if the limit values like TLV are exceeded:
use respiratory equipment with suitable filter or wear a self contained respiratory apparatus
Hand protection
Glove material for example, butyl-rubber
Material thickness 0,5 mm
Break through time >= 480 min
Glove material for example, Fluorinated rubber (Viton)
Material thickness 0,4 mm
Break through time >= 480 min
Selection of protective gloves to meet the requirements of specific workplaces.
Suitability for specific workplaces should be clarified with protective glove manufacturers.
The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.
Remember that the useful time per day of a chemical protection glove may be much shorter than the permeation time determined according to EN 374 due to the many different influential factors involved (e.g. temperature).
Eye protection
Safety glasses with side-shields
Hygiene measures
Avoid contact with skin and eyes.
Do not inhale vapours / aerosols.
Remove contaminated or saturated clothing.
When using do not eat, drink or smoke.
Stability and reactivity
Hazardous decomposition products
Decomposition products from hydrolysis in water
propanol
Disposal considerations
Product
With respect to local regulations, e.g. dispose of to suitable waste incineration plant.
Uncleaned packaging
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.
Incorrect disposal or reuse of this container is illegal and can be dangerous.
Other countries: observe the national regulations.
Waste Key Number
No waste key number as per the European Waste Types List can be assigned to this product, since such classification is based on the (as yet undetermined) use to which the product is put by the consumer.
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.