Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin sensitisation

Currently viewing:

Administrative data

Endpoint:
skin sensitisation: in vivo (LLNA)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-03-28 to 2012-04-19
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 429 (Skin Sensitisation: Local Lymph Node Assay)
Version / remarks:
2010-07-22
Deviations:
yes
Remarks:
modified OECD 429 ,method according to Ehlings et al. 2005
Principles of method if other than guideline:
The test was performed in accordance with the method according to Ehling et al (2005): An european inter-laboratory validation of alternative endpoints of the murine local lymph node assay: first round, Toxicology 212 (2005) 60-68 and Ehling et al (2005): An european inter-laboratory validation of alternative endpoints of the murine local lymph node assay: 2nd round, Toxicology 212 (2005) 69-79.

Threshold values of the stimulation indices of lymph node cell count (i.e. sensitising properties) and ear weight (i.e. irritating properties) were calculated by dividing the average values per group of the test item treated animals by the vehicle treated ones. Values above 1.4 (cell count) or 1.1 (ear weight) are considered positive
(these values were fixed empirically during the inter-laboratory validation of this method). In addition, the lymph node weights were determined for concentration related properties.
GLP compliance:
yes (incl. QA statement)
Remarks:
signed 2009-11-12
Type of study:
mouse local lymph node assay (LLNA)

Test material