Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-04-05 to 2016-08-05
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
relating to ASTM D93 with regard to Pensky-Martens apparatus
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Remarks:
Merieux NutriSciences operates according to GLP Certification of Good Laboratory Practice
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
0.13037 Pa*s
Specific details on test material used for the study:
Lot No.: 50000067900
Key result
Flash point:
210 °C
Atm. press.:
1 013 hPa

The results of duplicate determinations of the flash point for the test substance were 209°C and 211°C.

Averaging results in the final value for the flash point: 210°C (standard deviation 1.4°C; RSD 0.7%).

Interpretation of results:
GHS criteria not met
Remarks:
No classification for flammable liquids does apply, considering also UN-GHS criteria.
Conclusions:
Flash point (EU Method A.9/ASTM D93): 210 °C at 1013 hPa
Executive summary:

The flash point was determined according to EU Method A.9/ASTM D93 (Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester): flash point 210°C at 1013 hPa. Two replicate measurements were performed, resulting in very similar values (209°C and 211°C). In conclusion, there are no classification requirements with regard to flammble liquids for the test item, considering also UN-GHS criteria.

Description of key information

Flash point (EU Method A.9/ASTM D93): 210 °C at 1013 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
210 °C

Additional information

The flash point was determined according to EU Method A.9/ASTM D93 (Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester): flash point 210°C at 1013 hPa. Two replicate measurements were performed, resulting in very similar values (209°C and 211°C). In conclusion, there are no classification requirements with regard to flammble liquids for the test item, considering also UN-GHS criteria.