Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to international guideline(s), GLP-compliant, performed in recognized contract research organization, no restrictions, fully adequate for assessment.
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Auto-ignition temperature:
392 °C
Atm. press.:
99 kPa
Remarks on result:
other:

Table 1

Experiment No.

Temperature inside the flask

External Temperature

Ignition

Sample amount

Ignition

delay time

1

99 °C

102 °C

-

100 µl

-

2

199 °C

206 °C

-

100 µl

-

3

300 °C

310 °C

-

100 µl

-

4

301 °C

310 °C

-

500 µl

-

5

350 °C

362 °C

-

100 µl

-

6

350 °C

362 °C

-

500 µl

-

7

400 °C

413 °C

-

100 µl

-

8

400 °C

413 °C

+

500 µl

1.17 min

9

401 °C

413 °C

+

500 µl

1.34 min

10

392 °C

400 °C

+

500 µl

1.17 min

11

381 °C

390 °C

-

500 µl

 

12

385 °C

393 °C

-

500 µl

 

13

389 °C

398 °C

-

500 µl

 

14

389 °C

398 °C

-

500 µl

 

-   - not ignited

-   + ignited

Description of key information

392°C at 99 kPa (EU A.15)

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
392 °C

Additional information

The difference between the pressure measured during the test and the standard pressure is regarded as negligible.