Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 239-341-7 | CAS number: 15305-07-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 016
- Report date:
- 2016
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- Tris(N-hydroxy-N-nitrosophenylaminato-O,O')aluminium
- EC Number:
- 239-341-7
- EC Name:
- Tris(N-hydroxy-N-nitrosophenylaminato-O,O')aluminium
- Cas Number:
- 15305-07-4
- Molecular formula:
- C18H15AlN6O6
- IUPAC Name:
- aluminum tris(2-oxo-1-phenylhydrazinolate)
- Test material form:
- solid: particulate/powder
Constituent 1
- Specific details on test material used for the study:
- Name: RCX 15-116
Batch No.: 15047AE2
Purity: > 99%
CAS No.: 15305-07-4
Chemical Name: Aluminium-N-nitrosophenylhydroxylamine (NPAL)
Aggregate State at RT: solid
Colour: whitish
Storage Conditions: room temperature, protected from light
Stability: instable after repeated contact to air and / or light, undergoes hydrolysis
Expiry Date: 30 Nov 2016
Safety Precautions: the routine hygienic procedures were sufficient to assure personnel health and safety.
Test animals / tissue source
- Species:
- other: cows
Test system
- Vehicle:
- physiological saline
- Amount / concentration applied:
- 750 µL of the pure test item preparation or the control substance was applied.
- Duration of treatment / exposure:
- fter 4 hours ± 5 minutes incubation at 32 ± 1 °C either the test substance or the control substance was removed and the epithelium washed at least three times with MEM (containing phenol red). Once the medium was free of test substance, the cornea was finally rinsed with complete RPMI (without phenol red). The anterior chamber was refilled with complete RPMI and an illuminance measurement was performed. Also, each cornea was observed visually, no pertinent observations were recorded. After the illuminance measurement was performed, the medium was removed from both chambers of the holder. The posterior chamber was refilled with fresh complete RPMI. 1 mL of a 5 mg/mL sodium fluorescein solution was added to the anterior chamber and the corneas were incubated for 90 minutes at 32 ± 1 °C. Then the medium from the posterior chamber was removed and its optical density at 490 nm (OD490) was determined, using a spectrophotometer (Jenway 6405 UV/VIS).
- Number of animals or in vitro replicates:
- 3 corneas for the test item, 3 corneas as negative controls treated with physiological saline 0.9% NaCl, 3 corneas as positive controls treated with imidazole 20% in physiological saline 0.9% NaCl.
The BCOP assay is considered to be valid if the in vitro irritation score obtained with the positive control falls within the two standard deviations of the current historical mean. The negative control responses should result in opacity and permeability values that are less than the established upper limits for background bovine corneas treated with the respective negative control. - Details on study design:
- Preparation of the Corneas
The assay uses isolated corneas obtained as a by-product from animals freshly slaughtered at the abattoir A. Moksel AG, Buchloe, Germany. On the test day, fresh eyes were collected from the slaughterhouse and were transported in HBSS containing Pen/Strep on ice to the laboratories. Immediately after arrival of the eyes, cornea preparation was initiated. The eyes were carefully examined for defects and any defective eyes were discarded. The tissue surrounding the eyeball was carefully pulled away and the cornea was excised leaving a 2 to 3 mm rim of sclera. The isolated corneas were stored in a petri dish containing HBSS. Before the corneas were mounted in corneal holders (Duratec GmbH) with the endothelial side against the O-ring of the posterior chamber, they had been visually examined for defects and any defective cornea had been discarded. The anterior chamber was then positioned on top of the cornea and tightened with screws. The chambers of the corneal holder were then filled with RPMI (without phenol red) containing 1% FBS and 2 mM L-glutamine (complete RPMI). The posterior chamber was always filled first. The corneas were incubated for one hour at 32 ± 1 °C.
Calibration of the Opacitometer
The opacitometer (BASF-OP3.0, Duratec GmbH) was switched on at least 15 min before starting the calibration procedure. The filter holder was placed into the opacitometer and the readout was adjusted to 1000 lux ± 10 lux using the “Calibrate”-turning knob. For calibration the glass filter F2 was introduced into the filter holder. The readout lied in the range between 540-560 lux. To test the linearity of the measurement, two additional calibration filters, glass filter F3 and glass filter F4, were measured. For these glass filters, the opacitometer displayed values between 300-310 lux and between 95-105 lux. The calibration procedure was performed before the test and is documented in the raw data.
Treatment of the Corneas
After the equilibration period, the medium was removed from both chambers and replaced with fresh complete RPMI. An initial measurement was performed on each of the corneas using the opacitometer. Three corneas with illuminance readings approximately equivalent to the median illuminance of all corneas were selected as negative-control corneas. The illuminance of each cornea was read and recorded. Only corneas that had an initial illuminance reading I > I0/1.1651 lux were used for the assay. The medium was removed from the anterior chamber and replaced with the test item or control. 750 µL of the test item preparation or the control substance was introduced into the anterior chamber (closed-chamber method). After 4 hours ± 5 minutes incubation at 32 ± 1 °C either the test substance or the control substance was removed and the epithelium washed at least three times with MEM (containing phenol red). Once the medium was free of test substance, the cornea was finally rinsed with complete RPMI (without phenol red). The anterior chamber was refilled with complete RPMI and an illuminance measurement was performed. Also, each cornea was observed visually, no pertinent observations were recorded. After the illuminance measurement was performed, the medium was removed from both chambers of the holder. The posterior chamber was refilled with fresh complete RPMI. 1 mL of a 5 mg/mL sodium fluorescein solution was added to the anterior chamber and the corneas were incubated for 90 minutes at 32 ± 1 °C. Then the medium from the posterior chamber was removed and its optical density at 490 nm (OD490) was determined, using a spectrophotometer (Jenway 6405 UV/VIS).
Results and discussion
In vitro
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Value:
- 0.63
- Vehicle controls validity:
- valid
- Negative controls validity:
- not applicable
- Positive controls validity:
- valid
- Irritation parameter:
- in vitro irritation score
- Value:
- 1.02
- Vehicle controls validity:
- valid
- Negative controls validity:
- not applicable
- Positive controls validity:
- valid
- Irritation parameter:
- other: permeability
- Value:
- 0.026
- Vehicle controls validity:
- valid
- Negative controls validity:
- not applicable
- Positive controls validity:
- valid
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- RCX 15-116 did not show any irritancy potential in the bovine corneal opacity and permeability assay.
- Executive summary:
The eye irritancy potential of RCX 15-116 was investigated in the bovine corneal opacity and permeability assay. Technically not possible to gain a 20% concentration, therefore the test item was applied directly.
The following mean in vitro irritation score was calculated: 1.02. Therefore the test item does not need to be classified as an eye irritant.
The in vitro irritation score obtained with the positive control fell within the two standard deviations of the current historical mean and therefore this assay is considered to be valid. The negative control responses should result in opacity and permeability values that are less than the established upper limits for background bovine corneas treated with the respective negative control.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.