Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 701-396-4 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Auto flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- auto-ignition temperature (liquids)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 11 Apr 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- GLP guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
- Version / remarks:
- adopted in 2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- National Institute of Pharmacy and Nutrition, Budapest, Hungary
- Key result
- Auto-ignition temperature:
- > 400 °C
- Atm. press.:
- ca. 973 hPa
- Remarks on result:
- not determinable
- Remarks:
- No ignition-temperature of LZ 53478 was determined up to 400 °C
Reference
Result
Temperature was measured in case of each experiment at the outside and inside of the flask. The temperature distribution was steady outside the flask.
The experiment was carried out at 973 hPa atmospheric pressure.
The details are summarized in Table 1.
Table 1: Determination of auto-ignition temperature of test item
Temperature (flask inside) |
External temperature |
Ignition |
Sample amount |
Time-lag |
233 °C |
235 °C |
- |
~100 μL |
- |
300 °C |
301 °C |
- |
~100 μL |
- |
349 °C |
351 °C |
- |
~100 μL |
- |
396 °C |
399°C |
+ |
~100 μL |
0 sec |
398 °C |
400 °C |
- |
~250 μL |
- |
- - not ignited - + ignited
|
No ignition-temperature of LZ 53478 was determined up to 400 °C.
Deviation to the study plan
The study was carried out with the following deviation:
The test item has to be heated to approximately 50 °C instead of 30-40 °C as given in the study plan.
Reason: scientific reason
The deviation has no impact on the integrity of the study. No deviation from the method but only from the study plan.
Description of key information
> 400.0 °C at 973.0 hPa (EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases)))
Key value for chemical safety assessment
- Autoflammability / Self-ignition temperature at 101 325 Pa:
- 400 °C
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.