Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 688-947-1 | CAS number: 98092-92-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- August 10, 2016 - October 21, 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Deviations:
- no
- Principles of method if other than guideline:
- Because of the chemical nature of the test item (surface-active material), neither OECD Guideline No. 117 (HPLC Method) nor OECD Guideline No. 122 (pH-metric Method) can be applied. OECD Guideline No. 107 states that for such substances, an estimation of the partition coefficient (n-octanol/water) shall be calculated on the basis of the test item solubility in the two pure solvents.
- GLP compliance:
- no
- Type of method:
- flask method
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- Internal sample code: 2929564-001
Purity: 100.3% w/w
Batch number: 2510468 - Analytical method:
- other: flask method
- Key result
- Type:
- log Pow
- Partition coefficient:
- ca. 0
- Temp.:
- 20 °C
- Remarks on result:
- other: Estimated between log Pow < - 0.40 and log Pow < - 0.22
- Conclusions:
- From the obtained experimental data, it can be concluded that the Partition Coefficient (Pow) of Delmopinolo HCl Technical sample is estimated to be between < 0.4 (log Pow < - 0.40) and < 0.6 (log Pow < - 0.22) at room temperature (ca. 20°C).
- Executive summary:
Partition Coefficient (Pow) of Delmopinolo HCl is estimated to be between < 0.4 (log Pow < - 0.40) and < 0.6 (log Pow < - 0.22) at room temperature (ca. 20°C)
Reference
Result
Using the analytical balance, two amounts of test item, 101.6 mg and 100.9 mg respectively, were weighed into two test tubes and increasing measured volumes of n-octanolat room temperature (ca.)were added, as reported in table below:
Delmopinolo HCl: n-octanol solubility test.
Approximate solubility (g/L) |
Total volume required for complete dissolution (mL) |
Solubility after 30 min. |
> 1000 |
0.10 |
Complete |
In order to obtain a more accurate value of n-octanol solubility a second test was performed.
Using the analytical balance, test item aliquots were weighed in duplicate and increasing measured volumes of n-octanolat room temperature (ca.)were added to each aliquot as indicated in the following table, until complete dissolution was obtained.
After each solvent addition, the mixture was shaken and then stored at test temperature with intermittent shaking for 30 minutes. The contents of the test tube were visually checked after 30 minutes and after 24 hours.
Delmopinolo HCl: n-octanol solubility test.
Solubility range (g/L) |
Weight (g) Test 1 |
Weight (g) Test 2 |
Volume of addition (mL) |
Solubility after 30 min. |
Solubility after 24 h |
>1500 |
3.0058 |
3.0007 |
2.00 |
Incomplete |
Incomplete |
Therefore the test item solubility in n-octanol was estimated to be between 1000 and 1500 g/L.
Due to the test item nature it was not possible to develop an analytical method able to quantify the test substance dissolved in n-octanol to get a more precise value.
A quantification using an UV/Vis spectrometer was tried but n-octanol adsorb in the very same region in which adsorb the test item preventing this technique to be used.
An HPLC/MS method was also tried but, even if the test item was detectable with mass spectroscopy, it was not possible to find suitable chromatographic conditions, probably due to the amphiphilic test item nature.
The mass, UV/Vis spectra and HPLC/MS chromatogram of Delmopinolo HCl are presented in Figures 1, 2 and 3 (see illustration).
Therefore the experimental phase was stopped after the preliminary test.
The water solubility value from this is > 2500 g/L.
The test item partition coefficient can be estimated as follows:
So 1 < x < 1.5 < 0.4 (log Pow < - 0.40)
Partition Coefficient (Pow) = ______ = ____________ =
Sw > 2.5 < 0.6 (log Pow < - 0.22)
where:
So = Test item solubility in n-octanol (g/L)
Sw = Test item solubility in water (g/L)
Description of key information
Because of the chemical nature of the test item (surface-active material), neither OECD Guideline No. 117 (HPLC Method) nor OECD Guideline No. 122 (pH-metric Method) can be applied. OECD Guideline No. 107 states that for such substances, an estimation of the partition coefficient (n-octanol/water) shall be calculated on the basis of the test item solubility in the two pure solvents.
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 0.6
- at the temperature of:
- 20 °C
Additional information
From the obtained experimental data, it can be concluded that the Partition Coefficient (Pow) of Delmopinolo HCl Technical sample is estimated to be between < 0.4 (log Pow < - 0.40) and < 0.6 (log Pow < - 0.22) at room temperature (ca. 20°C).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.