EC number: 700-446-2 | CAS number: 125768-93-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Risk of ignition. In case of splashes, remove contaminated clothing and plunge it into water immediately.
Inhalation:
Move to fresh air. Oxygen or artificial respiration if needed. Keep under medical surveillance. In case of persistent problems : Hospitalise.
Skin contact:
Wash immediately, abundantly and thoroughly with soap and water. If skin irritation persists, call a physician.
Eye contact:
Wash well-open eyes immediately, abundantly and thoroughly with water. Consult an ophthalmologist.
Ingestion:
Do NOT induce vomiting. In case of problems : Consult a doctor.
Protection of first-aiders:
In case of insufficient ventilation, wear suitable respiratory equipment. Protective suit
Fire-fighting measures
Special hazards arising from the substance or mixture:
Heating may cause a fire.
The product burns violently (protect people from possible projections). Through thermal decomposition, formation of very reactive free radicals.
Thermal decomposition giving flammable and toxic products: Alcohols, Ketones, Hydrocarbons, Carbon oxides
Advice for firefighters:
Specific methods:Fight fire from a distance (more than 15 m). Cool containers / tanks with water spray. In case of fire, remove exposed containers. Prohibit all sources of sparks and ignition - Do not smoke.
Special protective actions for fire-fighters: Wear self-contained breathing apparatus and protective suit.
Accidental release measures
Evacuate non-essential staff and those not equipped with individual protection apparatus. Prohibit all sources of sparks and ignition - Do not smoke. Avoid contact with skin and eyes and inhalation of vapours. Use personal protective equipment. In case of insufficient ventilation, wear suitable respiratory equipment.
Environmental precautions: Do not release into the environment. Do not let product enter drains.
Methods and materials for containment and cleaning up:
Methods for cleaning up: After cleaning, flush away traces with water. Recover waste water for processing later.
Recovery: Never return spills in original containers for re-use. Shovel into suitable container for disposal. Small quantities : Soak up with inert absorbent material (Vermiculite, Clean sand). Do not confine. No sparking tools should be used.
Handling and storage
Storage and handling precautions applicable to products: Organic peroxides. Liquid. dangerous for the envrionnment.
Provide appropriate exhaust ventilation at machinery. Provide showers, eye-baths. Provide water supplies near the point of use. Provide selfcontained breathing apparatus nearby. Provide fire-blanket nearby. Provide electrical earthing of equipment.
Safe handling advice:
Strictly limit the quantities of product in the work area to those which are absolutely necessary for the work in hand. Great cleanliness in work areas is a necessary and important factor for safety. Handle and open container with care (risk of overpressurization in containers). Prohibit all sources of sparks and ignition - Do not smoke. Protect from contamination. Never return any product to the container from which it was originally removed (risk of decomposition). Never mix peroxides directly with accelerators (risk of explosion). Add each component separately to the resin. In case of insufficient ventilation, wear suitable respiratory equipment.
Hygiene measures:
Take off immediately all contaminated clothing. Avoid contact with skin and eyes and inhalation of vapours. When using do not eat, drink or smoke.
Wash hands after handling. Remove contaminated clothing and protective equipment before entering eating areas.
Conditions for safe storage, including any incompatibilities:
Store in well insulated area (peroxide area) away from other substances. Storage buildings must be built and equipped so as not to exceed the maximum proscribed temperature limit. Use non-combustible construction materials. Keep tightly closed in a dry, cool and well-ventilated place. Keep away from heat and sources of ignition. Do not smoke. Store in original container. Use only very clean containers and equipment free from traces of impurities. Never return unused material to storage receptacle. Do not reuse empty packaging to store other products.
Provide earthing and safe electrical equipment. Provide a catch-tank in a bunded area. Provide impermeable floor.
Storage period: < 6 Months, Storage temperature: < 30 °C (to maintain the technical properties of the product).
Incompatible products:
Strong oxidizing agents, Powerful reducers, Acids, Bases, Amines, transition metal salts, Sulphur compounds, Rust, ash, dusts (risk of selfaccelerating exothermic decomposition)
Packaging material:
Recommended: High density polyethylene (HDPE), Polytetrafluoroethylene (PTFE), Stainless steel
To be avoided: Ordinary metals (ordinary steel), copper, rubber (natural or synthetic), Glass - Stoneware (risk of contents spurting or spraying out if container ruptures due to overpressurization)
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- 3103
Shipping information
- Proper shipping name and description:
- PEROXYDE ORGANIQUE DE TYPE C, LIQUIDE(PEROXYDE DE 1,1-DIMETHYLPROPYL 1-METHOXYCYCLOHEXYL)
- Chemical name:
- PEROXYDE ORGANIQUE DE TYPE C, LIQUIDE(PEROXYDE DE 1,1-DIMETHYLPROPYL 1-METHOXYCYCLOHEXYL)
- Language:
- French
- Labels:
- 5.2
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- not permitted for transport
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- 3103
Shipping information
- Proper shipping name and description:
- ORGANIC PEROXIDE TYPE C, LIQUID (1,1-dimethylpropyl 1-methoxycyclohexyl peroxide)
- Chemical name:
- 1,1-dimethylpropyl 1-methoxycyclohexyl peroxide)
- Labels:
- 5.2
- Marine pollutant
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- not permitted for transport
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
General protective measures: Provide sufficient air exchange and/or exhaust in work rooms.
Personal protective equipment:
Respiratory protection: In case of insufficient ventilation, wear suitable respiratory equipment. In the case of hazardous fumes, wear self contained breathing apparatus.
Hand protection: Gloves (PVC, neoprene, nitrile rubber)
Eye/face protection: Safety glasses/goggles and face-mask (during discharge)
Skin and body protection: Protective suit
Stability and reactivity
Possibility of hazardous reactions: Organic peroxides. At high temperature : risk of violent reaction (decomposition)
Conditions to avoid:
Temperatures above 30 °C (to maintain the technical properties of the product). Risk of explosion by shock, friction, fire or other sources of ignition. Keep away from heat and sources of ignition (risk of exothermic decomposition).
Incompatible materials to avoid: Strong oxidizing agents, Powerful reducers, Acids, Bases, Amines, transition metal salts, Sulphur compounds, Rust, ash, dusts (risk of selfaccelerating exothermic decomposition) Follow conditions of use with : accelerators (amines, metallic salts).
Thermal decomposition: Decomposition temperature: starts at 110 °C
Through thermal decomposition, formation of very reactive free radicals.
Thermal decomposition giving flammable and toxic products: Alcohols, Ketones, Hydrocarbons, Carbon oxides
Disposal considerations
Disposal of product: Do not dispose of waste into sewer. Eliminate the product by incineration after dilution in a suitable flammable solvent (in accordance with local and national regulations). Amount of active oxygen must be below 1%. Can be disposed of as waste water, when in compliance with local regulations.
Disposal of packaging: Do not release into the environment. Destroy packaging by incineration at an approved waste disposal site (in accordance with local and national regulations).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.