Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Not GLP study
Qualifier:
equivalent or similar to guideline
Guideline:
other: internal method based on official guideline
Principles of method if other than guideline:
The sample was dispersed, stirred and ultrasonicated prior the analytical characterisation by light scattering.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
ca. 5.684 µm
Remarks on result:
other: Sonicated for 2 minutes
Percentile:
D50
Mean:
ca. 23.28 µm
Remarks on result:
other: Sonicated for 2 minutes
Percentile:
D90
Mean:
ca. 57.156 µm
Remarks on result:
other: Sonicated for 2 minutes
Conclusions:
The substance particle size distribution was measured by light scattering and the results are D10=5.684 µm, D50= 23.28 µm and D90= 57.156 µm
Executive summary:

The substance particle size distribution was measured by light scattering and the results are D10=5.684 µm, D50= 23.28 µm and D90= 57.156 µm.

Description of key information

D10= 5.684µm
D50= 23.28 µm
D90= 57.156 µm

Additional information

The particle size distribution was determined by light scattering (REACH&Colours Kft, 2015) and resulted to have the following parameters D10=5.684 µm, D50= 23.28 µm and D90= 57.156 µm