Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 251-394-8 | CAS number: 33145-10-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Skin irritation / corrosion
Administrative data
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 14 March 2016 to 18 March 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Justification for type of information:
- Study performed in accordance with OECD & EU test guidelines in compliance with GLP and reported with a valid GLP certificate.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 016
- Report date:
- 2016
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- 2,2'-(2-methylpropylidene)bis[4,6-xylenol]
- EC Number:
- 251-394-8
- EC Name:
- 2,2'-(2-methylpropylidene)bis[4,6-xylenol]
- Cas Number:
- 33145-10-7
- Molecular formula:
- C20H26O2
- IUPAC Name:
- 2-[1-(2-hydroxy-3,5-dimethylphenyl)-2-methylpropyl]-4,6-dimethylphenol
- Test material form:
- solid: particulate/powder
- Remarks:
- migrated information: powder
- Details on test material:
- Identification: Lowinox® 22IB46IUPAC: 2,2’-(2-methylpropylidene)bis[4,6-xylenol]Appearance: White to cream coloured powderBatch: WB44L0016Purity/Composition: 99.7%Test item storage: At room temperatureStable under storage conditions until: 18 November 2018 (retest date)
Constituent 1
In vitro test system
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- other: Normal human-derived epidermal keratinocytes
- Source strain:
- other: EpiDerm Reconstructed Human Epidermis, EPI-200, EPI-212, LOT: 23662
- Details on animal used as source of test system:
- EpiDerm Skin Model (EPI-200, Lot no.: 23662 kit DD and EE).The model consists of normal, human-derived epidermal keratinocytes which have been cultured to form a multilayered, highly differentiated model of the human epidermis. It consists of organized basal, spinous and granular layers, and a multi-layered stratum corneum containing intercellular lamellar lipid layers arranged in patterns analogous to those found in vivo. The EpiDerm tissues (surface 0.6 cm²) were cultured on polycarbonate membranes of 10 mm cell culture inserts.
Source: MatTek Corporation, Ashland MA, U.S.A.
Tissues: On the day of receipt the tissues were kept on agarose and stored in the refrigerator. On the next day, at least one hour before starting the assay the tissues were transferred to 6-well plates with 0.9 ml DMEM medium. - Justification for test system used:
- Recommended test system in international guidelines (OECD and EC).
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- Reference items
Negative control: Milli-Q water (Millipore Corp., Bedford, Mass., USA).
Positive control: Potassium hydroxide (KOH; Merck, Darmstadt, Germany), an 8.0 normal solution was prepared.
Test item preparation: No correction was made for the purity/composition of the test item. The solid test item was applied directly on top of the skin tissue. Lowinox® 22IB46 was spread to match the size of the tissue. - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- yes, concurrent MTT non-specific colour control
- Amount/concentration applied:
- 32.8 to 34.4 mg
- Duration of treatment / exposure:
- 3 minutes & 1 hour
- Duration of post-treatment incubation (if applicable):
- Not applicable
- Number of replicates:
- 2 tissues per test group (3 minutes exposure, 1 hour exposure, negative control, positive control).
Test animals
- Species:
- other: Human
- Strain:
- other: EpiDerm Skin Model (EPI-200, Lot no.: 23662 kit DD and EE).
- Details on test animals or test system and environmental conditions:
- Environmental conditions: All incubations, with the exception of the test item incubation of 3 minutes at room temperature, were carried out in a controlled environment, in which optimal conditions were a humid atmosphere of 80 - 100% (actual range 67 - 86%), containing 5.0 ± 0.5% CO2 in air in the dark at 37.0 ± 1.0°C (actual range 36.3 - 37.3°C). Temperature and humidity were continuously monitored throughout the experiment. The CO2 percentage was monitored once on each working day. Temporary deviations from the temperature, humidity and CO2 percentage may occur due to opening and closing of the incubator door. Based on laboratory historical data these deviations are considered not to affect the study integrity.
Test system
- Type of coverage:
- open
- Preparation of test site:
- other: See details on Study Design
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Duration of treatment / exposure:
- 32.8 to 34.4 mg
- Observation period:
- 3 minutes & 1 hour
- Number of animals:
- 2 tissues per test group (3 minutes exposure, 1 hour exposure, negative control, positive control).
- Details on study design:
- Test for the interference of the test item with the MTT endpoint: A test item may interfere with the MTT endpoint if it is coloured and/or it is able to directly reduce MTT. The cell viability measurement is affected only if the test item is present on the tissues when the MTT viability test is performed.
Test for colour interference by the test item: Lowinox® 22IB46 was checked for possible colour interference before the study was started. Some non-coloured test items may change into coloured items in aqueous conditions and thus stain the skin tissues during the 1-hour exposure. To assess the colour interference, at least 25 mg of Lowinox® 22IB46 or 50 μl Milli-Q water as a negative control were added to 0.3 ml Milli-Q water. The mixture was incubated for approximately 1 hour at 37.0 ± 1.0°C in the dark. At the end of the exposure time the mixture was shaken and it was checked if a blue / purple colour change was observed.
Test for reduction of MTT by the test item: Lowinox® 22IB46 was checked for possible direct MTT reduction before the study was started. To assess the ability of the test item to reduce MTT, at least 25 mg of Lowinox® 22IB46 was added to 1 ml MTT (Sigma, Zwijndrecht, The Netherlands) solution (1 mg/ml) in phosphate buffered saline. The mixture was incubated for approximately 1 hour at 37.0 ± 1.0ºC. A negative control, sterile Milli-Q water was tested concurrently. At the end of the exposure time it was checked if a blue / purple colour change or a blue / purple precipitate was observed.
Application/Treatment of the test item: The skin tissues were kept in the refrigerator the day they were received. The next day, at least 1 hour before the assay was started the tissues were transferred to 6-well plates containing 0.9 ml DMEM medium per well. The level of the DMEM medium was just beneath the tissue. The plates were incubated for approximately 2 hours at 37.0 ± 1.0ºC. The medium was replaced with fresh DMEM medium just before Lowinox® 22IB46 was applied. The test was performed on a total of 4 tissues per test item together with a negative control and positive control. Two tissues were used for a 3-minute exposure to Lowinox® 22IB46 and two for a 1-hour exposure. The skin was moistened with 25 μl Milli-Q water (Millipore Corp., Bedford, Mass., USA) to ensure close contact of the test item to the tissue and 32.8 to 34.4 mg of the solid test item was added into the 6-well plates on top of the skin tissues. The remaining tissues were treated with 50 μl Milli-Q water (negative control) and with 50 μl 8N KOH (positive control), respectively. After the exposure period, the tissues were washed with phosphate buffered saline (Invitrogen Corporation, Breda, The Netherlands) to remove residual test item. Rinsed tissues were kept in 24 well plates on 300 μl DMEM medium until 6 tissues (= one application time) were dosed and rinsed.
Cell viability measurement: The DMEM medium was replaced by 300 μl MTT-medium and tissues were incubated for 3 hours at 37°C in air containing 5% CO2. After incubation the tissues were washed with PBS and formazan was extracted with 2 ml isopropanol (MatTek corporation) over night at room temperature. The amount of extracted formazan was determined spectrophotometrically at 570 nm in triplicate with the TECAN Infinite® M200 Pro Plate Reader. Cell viability was calculated for each tissue as percentage of the mean of the negative control tissues. Skin corrosion potential of the test item was classified according to remaining cell viability following exposure of the test item with either of the two exposure times.
Results and discussion
In vitro
Resultsopen allclose all
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 3-minute application, mean tissue viability
- Value:
- 98
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other:
- Remarks:
- Not considered to be corrosive
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 1-hour application, mean tissue viability
- Value:
- 90
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- The mean tissue viability obtained after 3-minute and 1-hour treatments with Lowinox® 22IB46 compared to the negative control tissues. Skin corrosion is expressed as the remaining cell viability after exposure to the test item. The relative mean tissue viability obtained after the 3-minute and 1-hour treatments with Lowinox® 22IB46 compared to the negative control tissues was 98% and 90% respectively. Because the mean relative tissue viability for Lowinox® 22IB46 was not below 50% after 3 minutes treatment and not below 15% after 1 hour treatment Lowinox® 22IB46 is considered to be not corrosive.
Lowinox® 22IB46 was checked for colour interference in aqueous conditions and possible direct MTT reduction by adding the test item to MTT medium. Because the solutions did not turn blue / purple nor a blue / purple precipitate was observed it was concluded that Lowinox® 22IB46 did not interfere with the MTT endpoint.
Any other information on results incl. tables
Mean absorption in the in vitro skin corrosion test with Lowinox® 22IB46
|
3-minute application |
1-hour application |
||||||||
|
A (OD570) |
B (OD570) |
Mean (OD570) |
SD |
A (OD570) |
B (OD570) |
Mean (OD570) |
SD |
||
Negative control |
1.720 |
1.832 |
1.776 |
± |
0.079 |
1.971 |
1.891 |
1.931 |
± |
0.057 |
Lowinox® 22IB46 |
1.765 |
1.704 |
1.734 |
± |
0.043 |
1.752 |
1.717 |
1.734 |
± |
0.025 |
Positive control |
0.185 |
0.185 |
0.185 |
± |
0.000 |
0.202 |
0.122 |
0.162 |
± |
0.056 |
SD = Standard deviation
Duplicate exposures are indicated by A and B.
In this table the values are corrected for background absorption (0.0418). Isopropanol was used to measure the background absorption.
Mean tissue viability in the in vitro skin corrosion test with Lowinox® 22IB46
|
3-minute application viability (percentage of control) |
1-hour application viability (percentage of control) |
Negative control |
100 |
100 |
Lowinox® 22IB46 |
98 |
90 |
Positive control |
10 |
8 |
Coefficient of Variation between tissue replicates
|
3 minute |
1 hour |
Negative control |
6.1 |
4.1 |
Lowinox® 22IB46 |
3.4 |
2.0 |
Positive control |
0.1 |
39 |
CV (%) = 100 - [(lowest OD570/highest OD570) x 100%]
INDIVIDUAL OD MEASUREMENTS AT 570 NM
|
3-minute application (OD570) A B |
1-hour application (OD570) A B |
||
Negative control |
|
|||
OD570measurement 1 |
1.7293 |
1.8643 |
2.0186 |
1.9594 |
OD570measurement 2 |
1.7764 |
1.8906 |
2.0188 |
1.9330 |
OD570 measurement 3 |
1.7795 |
1.8673 |
2.0018 |
1.9065 |
Lowinox® 22IB46 |
|
|||
OD570 measurement 1 |
1.8329 |
1.7691 |
1.8182 |
1.7949 |
OD570measurement 2 |
1.7870 |
1.7502 |
1.7930 |
1.7290 |
OD570measurement 3 |
1.7997 |
1.7185 |
1.7706 |
1.752 |
Positive control |
|
|||
OD570measurement 1 |
0.2320 |
0.2262 |
0.2617 |
0.1636 |
OD570measurement 2 |
0.2217 |
0.2293 |
0.2356 |
0.1650 |
OD570measurement 3 |
0.2276 |
0.2263 |
0.2332 |
0.1635 |
OD = Optical density
Duplicate exposures are indicated by A and B.
HISTORICAL CONTROL DATA FOR IN VITRO SKIN CORROSION STUDIES
|
Negative control |
Positive control |
Positive control |
|||
|
3-minute treatment (OD570) |
1-hour treatment (OD570) |
3-minute treatment (OD570) |
1-hour treatment (OD570) |
3-minute treatment (% viability) |
1-hour treatment (% viability) |
Range |
1.324 – 2.615 |
1.361 – 2.352 |
0.172 – 0.56 |
0.057 – 0.277 |
6 – 22 |
3 – 12 |
Mean |
1.86 |
1.86 |
0.18 |
0.13 |
10.67 |
7.17 |
SD |
0.24 |
0.22 |
0.10 |
0.05 |
3.9 |
2.36 |
n |
65 |
67 |
64 |
61 |
30 |
30 |
SD = Standard deviation
n = Number of observations
The above mentioned historical control data range of the controls were obtained by collecting all data over the period of December 2012 to December 2015.
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- It is concluded that this test is valid and that Lowinox® 22IB46 is not corrosive in the in vitro skin corrosion test under the conditions of this study.
- Executive summary:
The objective of this study was to evaluate Lowinox® 22IB46 for its ability to induce skin corrosion. For this purpose Lowinox® 22IB46 was topically applied on a human three dimensional epidermal model. The possible corrosive potential of Lowinox® 22IB46 was tested through topical application for 3 minutes and 1 hour.
The study procedures described in this report were based on the most recent OECD and EC guidelines:
- Organisation for Economic Co-operation and Development (OECD), OECD Guidelines for Testing of Chemicals, Guideline no. 431: In Vitro Skin Corrosion: reconstructed human epidermis (RHE) test method (adopted 26 September 2014).
- European Community (EC). Commission regulation (EC) No. 440/2008, Part B: Methods for the Determination of Toxicity and other health effects, Guideline B.40 BIS: "In Vitro Skin Corrosion: Human Skin Model Test". Official Journal of the European Union No. L142, 31 May 2008.
Batch WB44L0016 of Lowinox® 22IB46 was a white to cream coloured powder with a purity of 99.7%. Skin tissue was moistened with 25 μl of Milli-Q water and at least 25 mg of Lowinox® 22IB46 was applied directly on top of the skin tissue.
The positive control had a mean relative tissue viability of 10% after 3 minutes exposure. The absolute mean OD570(optical density at 570 nm) of the negative control tissues was within the laboratory historical control data range. In the range of 20 - 100% viability the Coefficient of Variation between tissue replicates was < 7%, indicating that the test system functioned properly.
Skin corrosion is expressed as the remaining cell viability after exposure to the test item after 3 minutes and 1 hour. The relative mean tissue viability obtained after 3-minute and 1-hour treatments with Lowinox® 22IB46 compared to the negative control tissues was 98% and 90%, respectively.
Because the mean relative tissue viability for Lowinox® 22IB46 was not below 50% after the 3-minute treatment and not below 15% after the 1-hour treatment Lowinox® 22IB46 is considered to be not corrosive.
It is concluded that this test is valid and that Lowinox® 22IB46 is not corrosive in thein vitroskin corrosion test under the experimental conditions of this study.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.