Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6 September 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
ISO 2592 (Determination of flash and fire points - Cleveland open cup method)
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Cleveland apparatus
Key result
Flash point:
263 °C
Atm. press.:
ca. 1 013 hPa

Pressure was not reported. Data is estimated, because the test was conducted under ambient condition using an open cup system.

Description of key information

Flash point = 263.0 °C at ca. 1013 hPa (ISO 2592, Cleveland open cup method)

Since the measured flash-point is far above the classification limit and above 200 °C the open-cup method is accepted.

No value for pressure is reported. The test is conducted under ambient condition using an open cup system, 1013 Pa is therefore a reasonable estimation.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
263 °C

Additional information