Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Remarks:
kinematic
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-04-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Remarks:
ASTM D445
Qualifier:
equivalent or similar to guideline
Guideline:
ASTM D-445 (Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
170
Key result
Temp.:
other: 100 °C
Parameter:
kinematic viscosity (in mm²/s)
Value:
15.8
Conclusions:
The kinematic viscosity is:
170 cSt at 40 °C
15.8 cSt at 100 °C
Executive summary:

The kinematic viscosity using a similar method to ASTM D445 is:

170 cSt at 40 °C

15.8 cSt at 100 °C

Description of key information

The kinematic viscosity using a similar method to ASTM D445 is:

170 cSt at 40 °C

15.8 cSt at 100 °C

Key value for chemical safety assessment

Viscosity:
170 mm²/s (static)
at the temperature of:
40 °C

Additional information

The values of the supporting information (171 and 170 cSt at 40 °C) are very similar to the value of the key study.