EC number: 222-793-4 | CAS number: 3615-41-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- sieving
- Type of distribution:
- other: dry sieve analysis for granular material
- No.:
- #1
- Size:
- >= 250 µm
- Distribution:
- 78.8 %
- No.:
- #2
- Size:
- < 250 µm
- Distribution:
- 21 %
- No.:
- #3
- Size:
- < 20 µm
- Distribution:
- ca. 0.2 %
- Remarks on result:
- other: distribution was negligible at <20 µm
- Conclusions:
- 78.8% of particulate matter was ≥250 µm
21.0% of particulate matter was <250 µm
Negligible (ca. 0.2%) amount of particulate matter was <20.0 µm - Executive summary:
The particle size distribution of the test substance was determined using dry sieve analysis for granular material in accordance with OECD guideline 110. The testing was performed in duplicate using two separate sub-samples. The test material subsample masses used were 2.0378 and 2.0484 grams. No sieve clogging or static issues were observed at any point during the testing. For each subsample, over 99% of the test substance had particles either at or greater than ninety microns. The particle size distribution dramatically dropped off below ninety microns. The average amount of particulate matter either at or larger than 250 microns in the test substance was 78.8%. The average amount of particulate matter smaller than 250 microns in the test substance was 21.0%. The average amount of particulate matter smaller than 20.0 microns in the test substance was negligible. The mean weight percent recovery for the two analyses was 99.8%.
Reference
No sieve clogging or static issues were observed at any point during the testing. For each subsample, over 99% of the test substance had particles either at or greater than ninety microns. The particle size distribution dramatically dropped off below ninety microns.
Particle Size Distribution Recovery Data for Sample ID: 112C-314-1 |
||||
Sieve Size, µm |
Beaker Weight (empty), g |
Beaker Weight (w/residue), g |
Residue Weight (g) |
Percent1Recovered |
1000 |
111.1043 |
111.1153 |
0.0110 |
0.5 |
500 |
108.9491 |
109.6664 |
0.7173 |
35.2 |
250 |
111.1757 |
112.0504 |
0.8747 |
42.9 |
125 |
114.1203 |
114.5263 |
0.4060 |
19.9 |
90.0 |
104.8651 |
104.8864 |
0.0213 |
1.0 |
63.0 |
110.0129 |
110.0136 |
0.0007 |
< 0.1 |
45.0 |
110.7088 |
110.7088 |
0.0000 |
< 0.1 |
20.0 |
110.2907 |
110.2907 |
0.0000 |
< 0.1 |
< 20.0 |
113.6334 |
113.6334 |
0.0000 |
< 0.1 |
Initial sample weight (g) = 2.0378 Total weight recovered from sieves (g) = 2.0310 Total percent recovered = 99.7 % 1Generated using Microsoft® Excel in full precision mode. Manual calculations may vary slightly. |
Particle Size Distribution Recovery Data for Sample ID: 112C-314-2 |
||||
Sieve Size, µm |
Beaker Weight (empty), g |
Beaker Weight (w/residue), g |
Residue Weight (g) |
Percent1Recovered |
1000 |
109.7367 |
109.7580 |
0.0213 |
1.0 |
500 |
111.7791 |
112.5169 |
0.7378 |
36.0 |
250 |
114.7180 |
115.5754 |
0.8574 |
41.9 |
125 |
112.1867 |
112.5990 |
0.4123 |
20.1 |
90.0 |
109.5676 |
109.5822 |
0.0146 |
0.7 |
63.0 |
109.7650 |
109.7663 |
0.0013 |
0.1 |
45.0 |
110.7088 |
110.7088 |
0.0000 |
< 0.1 |
20.0 |
110.2908 |
110.2908 |
0.0000 |
< 0.1 |
< 20.0 |
113.6335 |
113.6335 |
0.0000 |
< 0.1 |
Initial sample weight (g) = 2.0484 Total weight recovered from sieves (g) = 2.0447 Total percent recovered = 99.8 % 1Generated using Microsoft® Excel in full precision mode. Manual calculations may vary slightly. |
Particle Size Distribution Recovery Data: Range Determination |
|||
Sieve Size, µm |
% Recovery Data 112-314-1 |
% Recovery Data 112-314-2 |
Range (%) |
1000 |
0.5 |
1.0 |
0.5 |
500 |
35.2 |
36.0 |
0.8 |
250 |
42.9 |
41.9 |
1.0 |
125 |
19.9 |
20.1 |
0.2 |
90.0 |
1.0 |
0.7 |
0.3 |
63.0 |
< 0.1 |
0.1 |
0.1 |
45.0 |
< 0.1 |
< 0.1 |
< 0.1 |
20.0 |
< 0.1 |
< 0.1 |
< 0.1 |
< 20.0 |
< 0.1 |
< 0.1 |
< 0.1 |
Range = Abs ((% recovery data 122C-314-1) – (% recovery data 122C-314-2)); calculated for each sieve size. 1Generated using Microsoft® Excel in full precision mode. Manual calculations may vary slightly. |
Summary of Particle Size Distribution: Mean Percent Recovery |
|
Sieve Size, µm |
Mean Percent1Recovered |
1000 |
0.8 |
500 |
35.6 |
250 |
42.4 |
125 |
20.0 |
90.0 |
0.9 |
63.0 |
0.1 |
45.0 |
0.0 |
20.0 |
0.0 |
< 20.0 |
0.0 |
1Generated using Microsoft® Excel in full precision mode. Manual calculations may vary slightly. |
Description of key information
OECD Guideline 110
Additional information
78.8% of particulate matter was ≥250 µm
21.0% of particulate matter was <250 µm
Negligible (ca. 0.2%) amount of particulate matter was <20.0 µm
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.