Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 August 2016 to 16 August 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
- Purity: 96.6%
- Description: yellow viscous liquid
Key result
Sample tested:
other: The structure of the test item was assessed for chemical groups that would imply oxidizing properties. Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites.
Remarks:
Full structural details are given in Bretherick’s Handbook of Reactive Chemical Hazards, 7th Edition, Academic Press, 2007.
Parameter:
other: prediction
Remarks on result:
other: There are no structural alerts within the chemical structure of the test item.
Remarks:
Based on the chemical structure of the test item the result for the oxidizing properties has been predicted as negative, non-oxidizing.

There are no structural alerts within the chemical structure of the test item.

Conclusions:
Based on the chemical structure of the test item the result for the oxidizing properties has been predicted as negative, non-oxidizing.
Executive summary:

Under the conditions of the study, the oxidising properties (liquids) has been predicted to be a negative, non-oxidising, based on the chemical structure of the test item, using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

Under the conditions of the study, the oxidising properties (liquids) has been predicted to be a negative, non-oxidising, based on the chemical structure of the test item, using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification