Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 918-322-3 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
OECD 439: negative
OECD 492: negative
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- August 23, 2017 - January 9, 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
- Version / remarks:
- Commission Regulation (EU) No. 640/2012 amending, for the purpose of its adaption to technical progress, Regulations (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006 of the European Parliament and the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH).
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
- Version / remarks:
- July 28, 2015
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: Skinethic skin irritation test -42bis Standard operating procedure (SOP) 2009
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- foreskin from a single donor
- Justification for test system used:
- standard model
- Vehicle:
- unchanged (no vehicle)
- Remarks:
- No vehicle used in this study; The test item was applied neat to the tissues.
- Details on test system:
- CELL CULTURE
- Supplier: EpiSkin/SkinEthic Laboratories, Lyon, France)
- Source: human keratinocytes cultured on a polycarbonate filter in conditions which permit their terminal differentiation
- Format: 24 well plate
- Batch: 17-RHE-094
- Expires: September 18, 2017
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment: room temperature
- Temperature of post-treatment incubation: 37°C
REMOVAL OF THE TEST MATERIAL AND CONTROL
After the end of the treatment interval, the residual test item was removed immediately by gently rinsing with a minimum volume of 25 mL DPBS using a pipette. Excess DPBS was removed by gently shaking the inserts and blotting the bottom with blotting paper.
DYE BINDING METHOD
- Dye used in the dye-binding assay: MTT
- Spectrophotometer:ELx800, BioTek Instruments GmbH, Bad Friedrichshall, Germany at 570 nm - Control samples:
- yes, concurrent negative control
- Amount/concentration applied:
- TEST MATERIAL: 16 mg of solid test material
NEGATIVE CONTROL: 16 µL (Dulbecco`s Phosphate-Buffered Saline)
POSITIVE CONTROL: 16 µL (5% aqueous solution of sodium dodecyl sulfate in deionised water) - Duration of treatment / exposure:
- 42 min (± 1 minute)
- Duration of post-treatment incubation (if applicable):
- 42 hours (± 1 hour)
- Number of replicates:
- 3
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Experiment 1 / Run 1
- Value:
- 100.6
- Vehicle controls validity:
- not applicable
- Remarks:
- The test item was applied neat to the tissues
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: none
- Direct-MTT reduction: none
- Colour interference with MTT: none
ACCEPTANCE OF RESULTS:
Acceptability of the Quality Control Data of the Skin Model with Reference to Historical Batch Data:
Acceptance Criterion Result
Negative control OD ≥ 0.8 and ≤ 3.0 1.570 to 1.686
Acceptability of the Positive and Negative Control stated by Episkin/SkinEthic Laboratories:
Acceptance Criterion Result
Mean OD negative control ≥ 1.2 1.616
Mean viability positive control < 40% 1.7%
SD of group-mean value ≤ 18% 5.9% (positive control)
3.8% (negative control)
Acceptability of the Positive and Negative Control based on Historical Data of the Testing Laboratory:
Acceptance Criterion Result
Mean OD negative control ≥ 1.455 1.616
Mean viability positive control ≤ 2.97% 1.7%
Test Item Data Acceptance Criteria:
Acceptance Criterion Result
SD of group-mean value ≤ 18% 7.4%
The study met all acceptance criteria. - Interpretation of results:
- not irritating
- Remarks:
- UN GHS: No Caterory (according to OECD TG 439)
- Conclusions:
- This study was performed according to GLP and the methods applied are fully compliant with OECD TG 439. Under the conditions of the present study, the test item is not considered to possess an irritant potential to skin (UN GHS: No Category).
- Executive summary:
This study was performed according to GLP and the methods applied are fully compliant with OECD TG 439. Under the conditions of the present study, the test item is not considered to possess an irritant potential to skin (UN GHS: No Category).
Reference
Group | Time / [min] | Mean OD | Mean Relative viability / [%] |
Negative Control | 42 | 1.616 | 100 |
Positive Control | 42 | 0.028 |
1.7 |
Test Material |
42 |
1.625 |
100.6 |
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- September 2, 2017 - January 9, 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- July 28, 2015
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: DB-ALM Protocol No. 164: Ocular Irritation Assay for Chemicals using EpiOcular™ EIT,
- Version / remarks:
- September 14, 2015
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: EpiOcular Eye Irritation Test (OCL-200-EIT) for the prediction of acute ocular irritation of chemicals; For use with MatTek Corporation`s Reconstructed Human EpiOcular Model; MatTek Corporation
- Version / remarks:
- June 29, 2015
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL: 50 mg per tissue
NEGATIVE / VEHICLE CONTROL: 50 µL per tissue
Sterile deionized water was used as negative control.
POSITIVE CONTROL: 50 µL per tissue
Designation: Methyl acetate
Supplier: MatTek In Vitro Life Science Laboratories
Lot-No.: 032817ISA
Catalog #: TC-MA
Purity (GC): 99.7%
Appearance: Colorless liquid
Expiration date: March 28, 2018
Storage: 15 to 30°C - Duration of treatment / exposure:
- 6 hours
- Number of animals or in vitro replicates:
- in vitro: duplicate design
- Irritation parameter:
- other: Viability %
- Run / experiment:
- Run 1 / Experiment 1
- Value:
- 130.7
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: No observations
ACCEPTANCE OF RESULTS:
1. The negative control OD is >0.8 and <2.5 (0.945 and 1.025).
2. The mean relative viability of the positive control is below 50% of the negative control viability (33.9%).
3. The difference of viability between the two relating tissues of a single chemical is <20% (values between 1.1% to 17.6%) in the same run (for positive and negative control tissues and tissues of single chemicals).
The study met all acceptance criteria - Interpretation of results:
- GHS criteria not met
- Conclusions:
- Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is labeled non-irritant (UN GHS: No Category).
- Executive summary:
This study was performed according to GLP and the methods applied are fully compliant with OECD TG 492. Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is labeled non-irritant (UN GHS: No Category).
Reference
Mean OD | Mean Viability | |
Negative Control | 0.985 | 100.0% |
Positive Control | 0.334 | 33.9% |
Test Item | 1.288 | 130.7% |
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Justification for classification or non-classification
Based on the provided information there is no need f or classification according to the EU Regulation (EC) No 1272/2008 on Classification, Labelling and Packaging of Substances and Mixtures, as amended for the 10th time in Regulation (EU) No 2017/776.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.