Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 May 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7100 (Viscosity)
Version / remarks:
1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D-445 (Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
Version / remarks:
2009
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
Version / remarks:
1994
Deviations:
no
GLP compliance:
yes
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
5.73
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.59

Test results at 20°C: 5.721 and 5.730 mm^2/s

Test results at 40°C: 3.597 and 3.591 mm^2/s

Conclusions:
The kinematic viscosity at 20°C and 40°C was determined to be 5.73 mm^2/s and 3.59 mm^2/s, resp.
Executive summary:

The kinematic viscosity of the substance was determined using the capillary viscometer method in a GLP study according to OECD 114, ISO 3104, OPPTS 830.7100 and ASTM D-445. The kinematic viscosity at 20°C and 40°C was determined in duplicate obtaining the mean values of 5.73 mm^2/s and 3.59 mm^2/s, resp.

Description of key information

The kinematic viscosity at 20°C and 40°C was determined to be 5.73 mm^2/s and 3.59 mm^2/s, resp.

Key value for chemical safety assessment

Additional information

Determined using the capillary viscometer method in a GLP study according to OECD 114, ISO 3104, OPPTS 830.7100 and ASTM D-445.