Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11.07. - 13.11.14
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
effusion method: vapour pressure balance
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0 hPa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0 hPa
Test no.:
#3
Temp.:
50 °C
Vapour pressure:
0.003 hPa

The vapour pressure was measured in the temperature range of 30 °C to 80 °C. The measured vapour pressures at the corresponding temperatures are listed below:

 

Temperature / °C

Vapour pressure / hPa

30

2.6 x 10E-4

40

7.7 x 10E-4

50

2.6 x 10E-3

60

8.2 x 10E-3

70

2.1 x 10E-2

 

The measurement at 80 °C showed an ambiguous behaviour. Therefore this measurement was not evaluated. After the measurement the measuring cell was nearly empty and therefore it can be assumed that there was not enough test item left for the measurement at 80 °C. The values for 20, 25 and 50 °C are calculated, using the Antoine constants A, B and C.

 

The following vapour pressure values for the test item were extrapolated from the experimental data:

 

20 °C: 6.7x10E-3 Pa

25 °C: 1.3x10E-2 Pa

50 °C: 2.7x10E-1 Pa

 

Conclusions:
The vapour pressure of the test item at 25 °C was determined to be 1.3x10E-2 Pa.
Executive summary:

A study was conducted according to OECD TG 104, Regulation (EC) No 440/2008 method A.4 and OPPTS 830.7950 to determine the vapour pressure of the test item. The vapour pressure of the test item was determined in the temperature range 30-80 °C. The measurement at 80 °C showed an ambiguous behaviour. Therefore this measurement was not evaluated. . The vapour pressure was calculated using the linear regression equation of the Log P versus 1/T function. The values for 20, 25 and 50 °C are calculated, using the Antoine constants A, B and C. The vapour pressure was calculated to be 6.7 x 10E-3 Pa at 20 °C and 1.3 x 10E-2 Pa at 25 °C and 2.7 x 10E-1 Pa at 50 °C respectively.

Description of key information

The vapour pressure of the test item at 25 °C was determined to be 1.3x10E-4 hPa (reference 4.6 -1).

Key value for chemical safety assessment

Vapour pressure:
0 hPa
at the temperature of:
25 °C

Additional information

A study was conducted according to OECD TG 104, Regulation (EC) No 440/2008 method A.4 to determine the vapour pressure of the test item (reference 4.6 -1). The vapour pressure of the test item was determined in the temperature range 30-80 °C. The measurement at 80 °C showed an ambiguous behaviour. Therefore this measurement was not evaluated. The vapour pressure was calculated using the linear regression equation of the Log P versus 1/T function. The values for 20, 25 and 50 °C are calculated, using the Antoine constants A, B and C. The vapour pressure was calculated to be 6.7 x 10E-3 Pa at 20 °C and 1.3 x 10E-2 Pa at 25 °C and 2.7 x 10E-1 Pa at 50 °C respectively.