Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
oxidising solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the organic substance contains oxygen or halogen atoms which are chemically bonded only to carbon or hydrogen and hence, the classification procedure does not need to be applied
Endpoint:
oxidising gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
oxidising liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid

Description of key information

The test item has not to be classified as oxidising solid, oxidising liquid or oxidising gas.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Oxidising gases (reference 4.15-2)

The test item is a solid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as oxidising gases.

Oxidising solids (reference 4.15-1)

According the screening procedures as described in Appendix 6 of the Recommendations on the Transport of dangerous goods Manual of Test and Criteria sixth revised editions United Nations 2015 for organic compounds, the classification procedure for oxidising substances of Division 5.1 need not to be applied if:

(a) The compound does not contain oxygen, fluorine or chlorine; or

(b) The compound contains oxygen, fluorine or chlorine and these elements are chemically bonded only to carbon or hydrogen.

 As the oxygen in the test item is solely chemically bonded only to carbon or hydrogen the classification procedure does not need to be applied.

Oxidising liquids (reference 4.15-3)

The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as oxidising liquid.

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No 1272/2008

Based on the chemical structure and taking into account the provisions laid down in Regulation (EC) No 1272/2008, as amended for the twelfth time in Regulation (EU) 2019/521, the substance is not considered to be classified for oxidising properties.