Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- (Q)SAR
- Adequacy of study:
- key study
- Study period:
- October 2nd, 2019
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- 1. SOFTWARE
iSafeRat® toolbox – in Silico Algorithms For Environmental Risk And Toxicity version 2.4
2. MODEL (incl. version number)
iSafeRat® holistic HA-QSAR v1.8
3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
CC1CC(C=C(C1O)C)C2CC=C(C2(C)C)C
experimental log Kow (5.00) used as input value for the QSAR model
4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached QMRF
5. APPLICABILITY DOMAIN
See attached QPRF
6. ADEQUACY OF THE RESULT
See attached QPRF - Reason / purpose for cross-reference:
- reference to other study
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Deviations:
- not applicable
- Remarks:
- QSAR model
- Principles of method if other than guideline:
- The purpose of the in silico study was to determine the water solubility of test item in pure water at 25 °C.
This QSPR model has been validated as a QSAR model to be compliant with the OECD recommendations for QSAR modeling (OECD, 2004) and predicts the endpoint value which would be expected when testing the substance under experimental conditions in a laboratory following the Guideline for Testing of Chemicals No. 105, "Water Solubility" (OECD, 1995). The determination was performed using a regression method in which validated log Kow values are plotted against the log of sub-cooled liquid water solubility from studies of high quality. These have been carried out using one of the methods recommended in the OECD guideline 105 or an adaptation of these. - GLP compliance:
- no
- Type of method:
- other: QSAR model
- Remarks:
- simple linear regression
- Specific details on test material used for the study:
- log Kow (experimental) = 5.00
- Key result
- Water solubility:
- 8.07 mg/L
- Temp.:
- 25 °C
- Remarks on result:
- other: pH not relevant by QSAR calculation
- Details on results:
- Applicability Domain
Descriptor domain
The log Kow used as the descriptor for this prediction falls within the descriptor domain of the model between a log Kow of 0.79 to 6.03. The test item falls within the response domain of the training set between a log water solubility (in log (mol/L)) of -5.92 to 0.01.
Structural fragment domain
All chemical groups within the molecular structure are represented within the datasets of the model.
Mechanism domain
Water solubility of the substance is determined using log Kow as the descriptor. The submodel used is dependent on the capability of the substance to participate in hydrogen bonding with water and octanol. iSafeRat® Holistic HA-QSAR includes the following submodels:
· Water Solubility submodel for Non-Polar Organic compounds:
for compounds which are neither donors, nor acceptors for hydrogen bonds (e.g. alkanes, halides, alkenes, thiols… etc.)
· Water Solubility submodel for Oxygenated, Non-Hydroxylated compounds (classical):
for hydrogen bond acceptor compounds which are not donors (e.g. ethers, mono-esters, ketones, aldehydes, epoxides, lactones, carbonates, (meth)acrylates)
· Water Solubility submodel for Oxygenated, Non-Hydroxylated compounds (diesters):
specific submodel for diester compounds.
· Water Solubility submodel for Oxygenated, Hydroxylated compounds:
for hydrogen bond acceptor and donor compounds (i.e. alcohols, ethoxylated alcohols, lactates and carboxylic acids).
· Water Solubility model for Alkyl-/Alkoxy-phenols:
for hydrogen bond acceptor and donor compounds which can participate in strong hydrogen bonds.
· Water Solubility model for Amino compounds:
for hydrogen bond acceptor and donor compounds which can be ionised (i.e. primary, secondary and tertiary amines).
Given the molecular structure of the substance (alcohol), the submodel used to predict its water solubility is the one dedicated to Oxygenated, Hydroxylated compounds, which are hydrogen bond acceptors and donors. - Executive summary:
A validated Quantitative Structure-Property Relationship (QSPR) model was used to calculate the water solubility of the test item.
The determination was performed using a regression method in which validated log Kow values are plotted against
the log of sub-cooled liquid water solubility from studies of high quality.
The experimentally determined log Kow was used as input.
The test item falls within the applicability domain of the model and was therefore reliably predicted for its water solubility. Therefore, this endpoint value can be considered valid and fit for purpose.
The water solubility of the test item was predicted as 8.07 mg.L-1 at 25°C.
95% confidence interval (α = 0.05): 6.03 – 10.8 mg.L-1
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- disregarded due to major methodological deficiencies
- Study period:
- 25 May to 21 June 2012
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- significant methodological deficiencies
- Remarks:
- The determination was conducted with the column elution method, which is not suitable for a liquid test substance.
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Type of method:
- column elution method
- Water solubility:
- 5.1 mg/L
- Temp.:
- 20 °C
- pH:
- 6.9
- Executive summary:
The water solubility of the test substance was determined according to EU A.6 guideline, column elution method.
As this method is considered not suitable for liquid test items, the solubility result was not retained.
But the information on the pH of the solution is considered of scientific interest : ca 6.9 à 5.1 mg/L.
Referenceopen allclose all
95% confidence interval (α = 0.05): 6.03 – 10.8 mg.L-1.
QSAR statistical parameters are given in the QMRF and the QPRF
Description of key information
Calculated water solubility = 8.07 mg/L at 25°C.
pH ca 6.9 for a 5.1 mg/L solution (exp.).
Key value for chemical safety assessment
- Water solubility:
- 8.07 mg/L
- at the temperature of:
- 25 °C
Additional information
An experimental study was available, but the result was disregarded, as the elution method, not suitable for liquids, was used. However the pH of the resulting solution was included as supporting scientific information of interest.
Therefore, the water solubility was reliably estimated by a validated QSAR, using the experimental logKow as input.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.