Administrative data

First-aid measures

Description of first aid measures:



General advice :


Move out of dangerous area.
Show this safety data sheet to the doctor in attendance.
Do not leave the victim unattended.



If inhaled :


If unconscious, place in recovery position and seek medical
advice.
If symptoms persist, call a physician.



In case of skin contact :


If skin irritation persists, call a physician.
If on skin, rinse well with water.
If on clothes, remove clothes.



In case of eye contact :


Remove contact lenses.
Immediately flush eyes for at least 15 minutes. Get medical
attention.



If swallowed :


Keep respiratory tract clear.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
If symptoms persist, call a physician.



Most important symptoms and effects, both acute and delayed:
Symptoms : no data available
Risks : no data available



Indication of any immediate medical attention and special treatment needed:
Treatment : no data available

Fire-fighting measures

Extinguishing media:
Suitable extinguishing media :


Dry chemical Alcohol-resistant foam
Carbon dioxide (CO2)
Water spray



Unsuitable extinguishing media:


no data available



Special hazards arising from the substance or mixture:
Specific hazards during firefighting : Do not allow run-off from fire fighting to enter drains or water courses.



Advice for firefighters:
Special protective equipment for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.
Further information : Collect contaminated fire extinguishing water separately. This must not be discharged into drains.
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Personal precautions : no data available



Environmental precautions:
Environmental precautions : Prevent product from entering drains. If the product contaminates rivers and lakes or drains inform
respective authorities.



Methods and materials for containment and cleaning up:
Methods for cleaning up : Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Keep in suitable, closed containers for disposal.



Reference to other sections: Not applicable

Handling and storage

Precautions for safe handling:
Advice on safe handling : Do not breathe vapours/dust.
Avoid contact with skin and eyes.
For personal protection see section 8 of SDS.
Smoking, eating and drinking should be prohibited in the application area.


Dispose of rinse water in accordance with local and national regulations.


Advice on protection against fire and explosion : Normal measures for preventive fire protection.
Temperature class : no data available
Fire-fighting class : no data available
Dust explosion class : no data available



Conditions for safe storage, including any incompatibilities:
Requirements for storage areas and containers : Keep container tightly closed in a dry and well-ventilated place.
Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Electrical installations / working materials must comply with the technological safety standards.



Further information on storage conditions: Ambient / 10-30°C (50-85°F), Dry, well ventilated, preferably full, hermetically sealed
Advice on common storage : Protect against light.Store under nitrogen
Storage class (TRGS 510) : 12 Non Combustible Liquids
Other data : No decomposition if stored and applied as directed.


Specific end use(s):
Specific use(s) : no data available

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Not regulated as dangerous good

Exposure controls / personal protection

Control parameters:
Contains no substances with occupational exposure limit values.



Exposure controls:
Exposure assessment: Exposures are dependent on the product being handled, the
potential for chemical release, and any resulting airborne concentrations or dermal
contact. Since product handling and release scenarios vary, and no two workplaces are
exactly alike, it is recommended that the potential for exposure be assessed prior to the
prod-uct’s use or introduction. Exposure assessments should be performed by an
occupational hygienist, industrial hygienist, or other qualified occupational or
environmental health professional. An exposure assessment should be conducted to
determine the efficacy of any ventilation and the need for additional PPE. The PPE
indicated below are recommendations for worst-case scenario exposures. An exposure
assessment will identify more applicable measures to be implemented. EN and ANSI
standards are mentioned in the following recommendations, consult equivalent local
standards when required.
PPE is always the last resort to avoid exposure. In any case technical and organisational
measures have to be explored and used prior to the selection of PPE. The PPE selection is for operators trained to work with chemicals according to good industrial hygiene and
safety practice. Operators have to be trained on the use of PPE.



Engineering measures:
Use engineering controls to maintain airborne levels below exposure limit requirements or
guidelines. If there are no applicable exposure limit requirements or guidelines, use the product
only with adequate ventilation.



Personal protective equipment:
Eye/face protection : Use safety goggles tested according to EN 166/ ANSI Z87.1 or equivalent local standard.
Hand protection : Use gloves when handling substance in open systems.
Inspect gloves prior to use. Train operators for proper use.If
only incidental exposure is expected: (work without direct
contact to substance) use gloves tested according EN 16523-
1/ASTM F739 or equivalent local standard breakthrough times
at least 10 minutes, tested for chemicals indicated in chapter 3
of this SDS. Change gloves frequently.
If direct skin contact is expected: use gloves tested according
to EN 16523-1/ASTM F739 or equivalent local standard,
tested for chemicals indicated in chapter 3 of this SDS.
Permeation time must exceed contact time.
Other skin protection : Wear working clothes covering arms and legs.
Respiratory protection : Respiratory protection should be worn when workplace
exposures exceed exposure limit requirements or guidelines.
If there are no applicable exposure limits or guidelines, use an
approved respirator where there is a potential for adverse
effects, including but not limited to respiratory irritation or odor,
or where indicated by the exposure assessment. Selection of
air-purifying or positive-pressure supplied-air will depend on
the results of the exposure assessment which includes an
evaluation of the specific operations and the potential airborne
concentrations. For emergency conditions, use an approved
positive-pressure self-contained breathing apparatus.
In case a risk analysis proved the cartridge respirator as
acceptable, use type:
ABEK-P3 (EN 14387) OR Combination Multi-gas/P100
(42CFR84.193; ANSI Z88.7 or equivalent local standard) as a
backup to engineering controls.
In absence of engineering controls, use self-contained
breathing apparatus or full face supplied air respirators.
Use respirators and components tested and approved under
appropriate government standards such as CEN (EU) or NIOSH 42 CFR 84(US).



Thermal hazards : Wear appropriate thermal protective clothing, when
necessary.
Hygiene measures : Remove contaminated clothing and protective equipment
before entering eating areas.
Do not eat, drink or smoke during work.
Wash hands any time after handling the product.



Environmental exposure controls
General advice : Prevent product from entering drains.
If the product contaminates rivers and lakes or drains inform
respective authorities.

Stability and reactivity

Reactivity: None


Chemical stability: The product is chemically stable.

Disposal considerations

Waste treatment methods
Product : The product should not be allowed to enter drains, water courses or the soil.
Do not contaminate ponds, waterways or ditches with chemical or used container.
Send to a licensed waste management company.



Contaminated packaging : Empty remaining contents.
Dispose of as unused product.
Do not re-use empty containers.



Dispose of in accordance with local regulations.