EC number: 446-570-8 | CAS number: 1127-01-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Emergency measure - Inhalation: In case of accident by inhalation: remove casaulty to fresh
air an keep at rest. If symptoms persist, call a physician.
Emergency measure - Eyes: Rinse with plenty of water and consult a physician.
Emergency measure - Skin: Wash off with soap and plenty of water. If symptoms persist,
call a physician.
Emergency measure - Ingestion: Do not induce vomiting. Rinse mouth with water. Consult a
physician.
Fire-fighting measures
Recommended extinguishing agent: water spray, foam, carbon dioxide, dry powder, sand
Product arising from burning: carbon monoxide, carbon dioxide, hydrogen chloride, water
Product determined by test: N
Protective equipment: In case of fire wear self contained breathing apparatus.
Use water spray to cool unopened containers.
Accidental release measures
Emergency measures in case of spillage: Avoid contact with spilled product or contaminated surfaces.
Wear personal protective equipment. Unprotected persons
must be kept away.
Sweep up or vacuum up spillage and collect in suitable
containers for disposal.
Dispose according local regulations.
Do not flush into surface water or sanitary sewer systems.
Handling and storage
This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 17(3) for on-site isolated intermediates and, in case the substance is transported to other sites for further processing, the substance should be handled at these sites under the Strictly Controlled Conditions as specified in REACH regulation Article 18(4). Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each manufacturing site.
Handling: All working methods must be designed so that exposure by
inhalation of the substance is minimized. In addition, skin
contact with the substance should be avoided. Closed, or at
least splashproof, equipment should be used during filling
and metered feeding as well as, if applicable, during
sampling. In the case of handling in open systems, any
vapours that can form must be extracted directly at the
point of origin. If technical extraction or ventilation
measures are not possible or are insufficient, respiratory
protection should be worn. To avoid skin contact, tested
protective gloves and, if applicable, suitable protective
clothing according to standard EN 368 (e.g. :::) should be
worn. Outdoor clothing should be kept separate from working
clothes.
Personal precautions while handling the product:
respiratory protection: filter apparatus, Filter ABEK-P2
eye protection: safety glasses
skin protection: gloves made fo PVC of nitrile rubber.
Avoid any contact:
Wash hands and face before breaks and immediately after
handling the product.
When using, do not eat, drink or smoke.
Keep away from fire and sources of ignition.
Take precautionary measures against static discharges.
Storage: Apply the VCI concept for the Mixed Storage of Chemicals.
Store in original container.
Keep container tightly closed.
Do not store in heat or direct sunlight.
Keep in a dry, cool and well-ventilated place.
Keep away from food, drink and animal feeding stuffs.
Packaging of the substance and or preparation: container, 20 MT
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: Not dangerous goods
Transport: For the internal transportation:
Use original containers or other unbreakable and correctly
labelled containers. Keep containers tightly closed and
secure by suitable measures against falling down.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 17(3) for on-site isolated intermediates and, in case the substance is transported to other sites for further processing, the substance should be handled at these sites under the Strictly Controlled Conditions as specified in REACH regulation Article 18(4). Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each manufacturing site.
Respiratory protection: No personal respiratory protective equipment normally required.
Hand protection: rubber gloves
Eye protection: safety glasses
Hygiene measures: Handle in accordance with good industrial hygiene and safety practice.
Stability and reactivity
Danger other than fire: none known
Chemical reaction with water: none known
Dust explosion: not applicable
Disposal considerations
Industry - Possibility of recovery/recycling: The substance is an intermediate in the chemical industry
and can not be reused.
Industry - Possibility of neutralisation: Hydrolysis at alkaline pH and elevated temperature.
Industry - Possibility of destruction: controlled discharge: Burning in an incinerator.
Industry - Possibility of destruction - incineration: Burning in an industrial incinerator with gas scrubber.
Industry - Possibility of destruction - water purification: Controll of sewage water.
Treatment in an industrial sewage water treatment plant.
Public at large - Possibility of recovery/recycling: Not applicable, industrial intermediate only.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.