Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: authoritative secondary source

Data source

Reference
Reference Type:
secondary source
Title:
Titan(III)-chlorid
Author:
GESTIS - Substance Database
Year:
2011
Bibliographic source:
GESTIS - Substance Database (Information system on hazardous substances of the Berufsgenossenschaften) as cited 19.08.2011

Materials and methods

Test guideline
Guideline:
other: no data
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
Titanium trichloride
EC Number:
231-728-9
EC Name:
Titanium trichloride
Cas Number:
7705-07-9
Molecular formula:
Cl3Ti
IUPAC Name:
titanium trichloride
Details on test material:
- Name of test material (as cited in study report): Titanium trichloride
- Analytical purity: pure (not indicated)

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
ignition on contact with air (not further specified)
Remarks:
corresponding to 'yes' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
ignition on contact with air (not further specified)
Remarks:
corresponding to 'yes' in migrated source record.

Any other information on results incl. tables

Spontaneously flammable solid.

Applicant's summary and conclusion