Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
other: statement
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: reliability 2 because the study result type is only a statement

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Qualifier:
according to guideline
Guideline:
other: UN no. ST/SG/AC.10/11/Rev.4, test O.1, 2003
Qualifier:
according to guideline
Guideline:
other: UN no. ST/SG/AC.10/11/Rev.4, Appendix 6, 2003
GLP compliance:
yes (incl. QA statement)

Test material

Results and discussion

Test results (Oxidising liquids)
Sample tested:
other: not specified (migrated information) statement
Parameter:
other: statement
Remarks on result:
other: result not specified (migrated information)
Remarks:
None of the components of the test substance does contain groups that act as an oxidizing agent. The oxygen atoms that are present in the molecular structure of the test substance are chemically bonded to carbon or hydrogen.
Test results (Oxidising solids)
Sample tested:
other: not specified (migrated information) statement
Parameter:
other: statement
Remarks on result:
other: result not specified (migrated information)
Remarks:
None of the components of the test substance does contain groups that act as an oxidizing agent. The oxygen atoms that are present in the molecular structure of the test substance are chemically bonded to carbon or hydrogen.

Any other information on results incl. tables

The molecular structure of impurities at <=1% were not taken into account.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information