Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Start date of the experimental work: 12 June 2009 and Completion date of the experimental work: 02 July 2009.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
221 °C
Atm. press.:
101.3 kPa

Full test results:

 Temperature (°C) Barometric Pressure (kPa) 

Ignition

Yes (y) / No (n) 

 Halo / enlarged test flame 

Yes (y) / No (n)

 20 -29  101.6  n  n
 30 -39   101.6  n  n
 40 -49   101.6  n  n
 50 -59   101.6  n  n
 60 -69   101.6  n  n
 70 -79   101.6  n  n
 80 -89   101.6  n  n
 90 -99   101.6  n  n
 100 -109   101.6  n  n
 110 -119   101.6  n  n
 120 -129 101.6  n  n
 130 -139   101.6  n  n
 140 -149   101.6  n  n
 150 -159   101.6  n  n
 160 -169   101.6  n  n
 170 -179   101.6  n  n
 180 -189   101.6  n  n
 190 -199   101.6  n  y
 200 -209   101.6  n  y
 210 -219   101.6  n  y
 220 -222   101.6  y
 223  101.6  y  n
          Fresh sample
 200 -209  101.7  n  y
 210 -220  101.7  n  y
 221  101.7  y  n
          Fresh sample
 200 -209  101.6  n  y
 210 -219  101.6  n  y
 220  101.6  n  y
 221  101.6  y  n

Closed Cup Flash Point Temperature : 221°C @ 101.3 kPa

Interpretation of results:
GHS criteria not met
Conclusions:
Closed Cup Flash Point Temperature : 221°C @ 101.3 kPa

Description of key information

Closed Cup Flash Point Temperature : 221°C @ 101.3 kPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
221 °C

Additional information