Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 500-107-7 | CAS number: 40039-93-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 30/07/2012-05/10/2012
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP comparable to OECD guideline
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- Principles of method if other than guideline:
- /
- GLP compliance:
- yes
- Type of method:
- HPLC estimation method
- Media:
- soil/sewage sludge
- Specific details on test material used for the study:
- Details on properties of test surrogate or analogue material (migrated information):
/ - Radiolabelling:
- no
- Test temperature:
- 40°C
- Details on study design: HPLC method:
- EQUIPMENT
- Apparatus: Agilent Series 1100/1200 HPLC
- Type, material and dimension of analytical (guard) column:Zorbax CN column (150 mm x 4.6 mm x 5 µm particle size)
- Detection system: Agilent Series 1200 varibale wavelength UV detector
MOBILE PHASES
- Type: Gradient mobile phase consisting of HPLC-grade Reagent Water and methanol (Initial 55% MeOH, 45% H2O).
- Experiments with additives carried out on separate columns: no
- pH:6
- Solutes for dissolving test and reference substances:Test substance in acetonitrile, Reference substances in acetonitrile or methanol
DETERMINATION OF DEAD TIME
- Method:by inert substances which are not retained by the column (injection of thiourea)
REFERENCE SUBSTANCES
- Identity: Bromobenzene, napthalene (99%), 1,2,4-trichlorobenzene, phenanthrene (98%), 1,1-Bis(4-chlorophenyl)-2,2,2-trichloroethane (98% 4,4 DDT)
DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column:10.0 mg/L and 50.0 mg/L
- Quantity of reference substances: 10-40 mg/L
- Intervals of calibration: none
REPETITIONS
- Number of determinations:3 at a concentration of 10.0 mg/L
EVALUATION
- Calculation of capacity factors k': k' = (tR-t0)/t0 where tR: retention time of the test substance or reference standard peak and t0: column dead time
- Determination of the log Koc value: calculated as follows:
log Koc = (log k' - Y intercept)/slope - Type:
- log Koc
- Value:
- 5.33
- Temp.:
- 40 °C
- Remarks on result:
- other: First peak
- Type:
- log Koc
- Value:
- > 5.63
- Temp.:
- 40 °C
- Remarks on result:
- other: second peak
- Type:
- log Koc
- Value:
- > 5.63
- Temp.:
- 40 °C
- Remarks on result:
- other: Third peak
- Details on results (HPLC method):
- - Retention times of reference substances used for calibration:
Thiourea: 1.956-1.960 min
Acetanilide: 2.566-2.624 min
Phenol: 2.695-2.688 min
Bromobenzene: 4.408-4.550 min
Napthalene: 5.377-5.445 min
1,2,4-TCB: 6.222-6.579 min
Phenanthrene: 9.815-10.409 min
- Details of fitted regression line (log k' vs. log Koc): R²= 0.9674, y=0.3359x-0.7650
- Graph of regression line attached: yes
- Average retention data for test substance: Peak 1: 22.72 min, Peak 2: 33.92 min, Peak 3: 34.23 min - Validity criteria fulfilled:
- yes
- Conclusions:
- Under the chromatographic conditions specified, Brominated Epoxy eluted as three discrete peaks. According to the Sponsor, the test substance is a mixture in which the main component is n = 1. The mean log KOC for the first test substance peak (n = 1) was determined to be 5.33 ± 0.011 log units (N = 3, CV = 0.21%). The mean log KOC for the second and third test substance peaks (n = 2 and 3, respectively) were both determined to be greater than 5.63 using the HPLC estimation method.
Reference
Description of key information
log Koc for brominated Epoxy
Key value for chemical safety assessment
- Koc at 20 °C:
- 213 796
Additional information
Under the chromatographic conditions specified, Brominated Epoxy eluted as three discrete peaks. The mean log Koc for the first test substance peak was determined to be 5.33 ± 0.011 log units (N = 3, CV = 0.21%). The mean log Koc for the second and third test substance peaks were both determined to be greater than 5.63 using the HPLC estimation method.
[LogKoc: 5.33]
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.