Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 30-Jul-2015 to 11-Aug-2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: The study has been performed according to OECD and/or EC guidelines and according to GLP principles.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 015
- Report date:
- 2015
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- other: OECD guideline 437 “Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage”
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: EU Method B.47 “Bovine corneal opacity and permeability method for identifying ocular corrosives and severe irritants
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Test material form:
- solid: flakes
Constituent 1
Test system
- Vehicle:
- unchanged (no vehicle)
- Amount / concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): approx. 300 mg per cornea
NEGATIVE CONTROL
- Amount(s) applied (volume or weight with unit): 750 µl of physiological saline per cornea
POSITIVE CONTROL
Amount(s) applied (volume or weight with unit): 750 µl per cornea
Concentration (if solution): 20% (w/v) Imidazole
- Duration of treatment / exposure:
- 240 minutes
- Details on study design:
- TEST SITE
- Isolated bovine cornea
REMOVAL OF TEST SUBSTANCE
- Washing (if done): yes
- Time after start of exposure: 240 minutes
SCORING SYSTEM:
- After exposure the cornea is thoroughly rinsed to remove the test substance followed by immediate opacity measurement and permeability evaluation of the cornea.
- The mean opacity and mean permeability values (OD490) were used for each treatment group to calculate an in vitro score:
In vitro irritancy score (IVIS) = mean opacity value + (15 x mean OD490 value).
TOOL USED TO ASSESS SCORE:
- opacitymeter and microplate reader
DATA EVALUATION:
In vitro score range UN GHS
≤ 3 No Category
> 3; ≤ 55 No prediction can be made
>55 Category 1
Results and discussion
In vitro
Results
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- means
- Value:
- 2.8
- Negative controls validity:
- valid
- Positive controls validity:
- valid
Any other information on results incl. tables
The individual in vitro irritancy scores for the negative controls ranged from -0.7 to 0.5. The individual positive control in vitro irritancy scores ranged from 146 to 156. The corneas treated with the positive control were turbid after the 240 minutes of treatment.
The corneas treated with Licocare RBW 106 showed opacity values ranging from 1.8 to 3.8 and permeability values ranging from -0.008 to 0.011. The corneas were slightly translucent after the 240 minutes of treatment with Licocare RBW 106. No pH effect of the test item was observed on the rinsing medium. Hence, the in vitro irritancy scores ranged from 2.0 to 3.7 after 240 minutes of treatment with Licocare RBW 106.
Applicant's summary and conclusion
- Interpretation of results:
- not irritating
- Remarks:
- Migrated information Criteria used for interpretation of results: EU
- Conclusions:
- Since Licocare RBW 106 induced an IVIS ≤ 3, no classification is required for eye irritation or serious eye damage.
- Executive summary:
The negative control responses for opacity and permeability were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas.The mean in vitro irritancy score of the positive control (20% (w/v) Imidazole) was 150 and within two standard deviations of the current historical positive control mean. It was therefore concluded that the test conditions were adequate and that the test system functioned properly.
Licocare RBW 106 did not induce ocular irritation through both endpoints, resulting in a meanin vitroirritancy score of 2.8 after 240 minutes of treatment.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
Although ECHA is providing a lot of online material in your language, part of this page is only in English. More about ECHA’s multilingual practice.
Welcome to the ECHA website. This site is not fully supported in Internet Explorer 7 (and earlier versions). Please upgrade your Internet Explorer to a newer version.
the-echa-website-uses-cookies
find-out-more-on how-we-use-cookies