Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 April 2003 - 9 May 2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: IEC Standard 1241-2-1, Part 2
Version / remarks:
minimum ignition temperature-layer
Deviations:
not specified
Principles of method if other than guideline:
Minimum ignitoin temperature (Layer) is the lowest temperature at which a powder layer will exotherm or spontaneously ignite on contact with a hot surface.
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Moisture content: 0.5% w/w
Batch number: H03421
Parameter:
other: Minimum ignition temperature - Layer
Value:
400
Remarks on result:
other:
Remarks:
No ignition or exotherm observed up to 400C

Screening Test 1:

Hot plate (C)

Sample (C) Time (min) Observations
237 145 34 Smoking
293  246 42 Melting and boiling
396 264 58

 Boiling black tar

Screening Test 2:

Hot plate (C)

Sample (C) Time (min) Observations
266 174 39 Boiling and smoking
355  154 52 Boiling black tar
Interpretation of results:
GHS criteria not met
Conclusions:
No ignition or exotherm observed up to temperatures of 400C.
Executive summary:

Maximum ignition temperature for a powder layer was measured according to SOP-08, using a controlled hot plate and Pico-log data acquisition system, based on IEC Standard 1241 -2 -1, Part 2. Two screening tests were performed. No ignition or exotherm was observed up to temperatures of 400C.

Description of key information

Maximum ignition temperature for a powder layer was measured according to SOP-08, using a controlled hot plate and Pico-log data acquisition system, based on IEC Standard 1241 -2 -1, Part 2. Two screening tests were performed. No ignition or exotherm was observed up to temperatures of 400C.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

The results of a minimum ignition temperature test, performed under GLP conditions, observed no ignition or exotherm up to temperatures of 400C.