Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Test dates: Aug.6, 2010 to Feb.4, 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Remarks:
The study was conducted according to an internationally recognised method, and under GLP, but experimental details are missing. The substance is adequately identified, but some data on composition is missing. Therefore validation applies with restrictions.
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
yes (incl. QA statement)
Remarks:
GIPC; effective July 24, 2009 (validity 18 months, postponed to Feb.28, 2011)
Type of method:
differential scanning calorimetry
Specific details on test material used for the study:
Storage conditions of test material: Room temperature protected from direct sun light.
Key result
Melting / freezing pt.:
-114.8 °C

Table 4.2/1: Melting point – results

 Test No.  Onset temperature
 1  -114.9°C
 2  -114.8°C
 3  -114.8°C
 Mean +/- SD  -114.8 +/- 0.1°C

Three successive tests were retained.

Mean onset for melting occurred at -114.8 ± 0.1 °C. The validity criteria were fulfilled: the standard deviation within the three replicate assessments did not exceed 0.5 °C.

Therefore the average value is retained as final result.

Executive summary:

The melting point of the test substance was determined under GLP according to EU A1 guideline, using differential scanning calorimetry (DSC) method.

Three main runs were performed, and the mean final temperature was retained.

The melting temperature of the test substance was determined to be -114.8 °C.

Description of key information

Experimental melting point (i.e. transition from solid to liquid) = -114.8°C.

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
-114.8 °C

Additional information

A reliable experimental study, conducted according to a recognized EC method and under GLP, is available.

Despite minor restrictions due to incomplete test item identification, it is considered as key study, and the result is retained as key data.