Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Mass fraction 99.6%  > 125 µm, 0.3% > 90 µm < 125 µm; No guideline followed;  Foell & Dilts (2012)

Additional information

The granulometry of the test material was assessed in a non-GLP study conducted to sound scientific principles with a sufficient level of detail to assess the quality of the presented results. The test material was passed through a series of sieve screens and the resulting mass fractions were determined. The test material was sieved through a 125 μm opening and a 90 μm opening sieve. Under the conditions of the test 99.6% of the sample was retained on the 125 µm screen, 0.3% of the sample was retained on the 90 µm screen and 0 % of the sample was collected below the 90 µm screen. Under the conditions of the test, the majority of the sample (99.6%) was determined to be > 125 µm. In accordance with EN481 (1993) the test material does not meet the definition of inhalable. The study was assigned a reliability score of 2 in line with the principles for assessing data quality as outlined in Klimisch (1997),