Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
experimental dates: 08-09 November 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to an internationally recognised method, and under GLP. No deviation was reported. The test substance is adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
Regulation (EC) No. 440/2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
IEC 60079-4 (Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature)
Version / remarks:
Anon (1987), Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition
temperature. IEC Publications 79-4, p1-19.
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
UK GLP compliance programme (inspected on 10 July 2012 / signed on 30 November 2012)
Key result
Auto-ignition temperature:
356 °C
Atm. press.:
>= 100.7 - <= 101.4 kPa

Table 4.12/1: Results of the auto-ignition temperature

Test temperature (°C)

Test volume (µL)

Ignition delay (s)

Observations

200 (clean flask)

70

> 300

No ignition.

250 (clean flask)

70

> 300

No ignition.

300 (clean flask)

70

> 300

No ignition.

350 (clean flask)

70

> 300

No ignition. Grey fumes emitted.

400

70

2

Orange flame, grey fumes emitted.

360 (clean flask)

70

3

Orange/blue flame, grey fumes emitted.

356 (clean flask)

70

5

Orange/blue flame, grey fumes emitted.

354 (clean flask)

70

> 300

No ignition. Grey fumes emitted.

354 (clean flask)

200

> 300

No ignition. Grey fumes emitted.

354 (clean flask)

400

> 300

No ignition. Grey fumes emitted.

354 (clean flask)

600

> 300

No ignition. Grey fumes emitted.

354 (clean flask)

800

> 300

No ignition. Grey fumes emitted.

354 (clean flask)

1000

> 300

No ignition. Grey fumes emitted.

Room temperature: 21 to 22 °C

Atmospheric pressure: 100.7 to 101.4 kPa

accuracy: +/-5°C

Conclusions:
This parameter/method is not relevant for classification, however the information is useful regarding process safety and potential additional fire hazard.
No particular hazard is anticipated in normal conditions of storage.
Executive summary:

The auto-ignition temperature of the test substance was measured under GLP according to IEC 79-4 method (listed in EU A15 guideline). The test substance was injected into a heated flask, until the lowest temperature at which ignition occurs was determined. The relevant parameters were recorded for the final result.

The auto-ignition temperature of the test substance has been determined to be 356 ± 5 °C.

Description of key information

No particular hazard is anticipated in normal conditions of storage.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
356 °C

Additional information

A fully reliable experimental study, conducted according to a recognized IEC/EU method and under GLP, is available. It is considered as a key study. The result is retained as key data.

This parameter is not relevant for classification, however the information is useful regarding process safety and potential additional fire hazard.