Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted using an acceptable method but not in compliance with GLP.
Principles of method if other than guideline:
The particle size distribution was performed by weighing sieves with defined mesh numbers before and after the sieving process.
GLP compliance:
no
Type of method:
sieving
Type of particle tested:
aggregate
Type of distribution:
mass based distribution
Key result
Percentile:
D50
Mean:
ca. 218 - ca. 321 µm
Remarks on result:
other: Mean particle size distribution for three samples
No.:
#1
Size:
< 100 µm
Distribution:
ca. 1.3 - ca. 3.7 %
Remarks on result:
other: Particle size distribution of samples 1 to 3
No.:
#2
Size:
< 45 µm
Distribution:
ca. 0 - ca. 0.2 %
Remarks on result:
other: Particle size distribution of samples 1 to 3

Results:

Table 1: sample 1

Sieve (µm)

Percentage (%)

Particle size (µm)

Sum (%)

500

30.0

>500

100.0

400

6.3

<500

70.0

250

28.1

<400

63.8

200

16.0

<250

35.7

125

17.2

<200

19.7

100

1.1

<125

2.5

63

1.0

<100

1.3

45

0.3

<63

0.3

Bottom

0.0

<45

0.0

Total

100.0

0

0.0

 

Mean particle size (DT50) = 318 µm

Table 2: sample 2

Sieve (µm)

Percentage (%)

Particle size (µm)

Sum (%)

500

12.2

>500

100.0

400

18.5

<500

87.8

250

41.5

<400

69.3

200

10.7

<250

27.8

125

13.8

<200

17.0

100

1.3

<125

3.2

63

1.5

<100

1.9

45

0.3

<63

0.4

Bottom

0.1

<45

0.1

Total

100.0

0

0.0

 

Mean particle size (DT50) = 321 µm

Table 3: sample 3

Sieve (µm)

Percentage (%)

Particle size (µm)

Sum (%)

500

2.7

>500

100.0

400

5.5

<500

97.3

250

22.7

<400

91.8

200

31.3

<250

69.1

125

31.3

<200

37.8

100

2.8

<125

3.7

63

3.2

<100

3.7

45

0.4

<63

0.5

Bottom

0.2

<45

0.2

Total

100.0

0

0.0

 

Mean particle size (DT50) = 218 µm

The particle size distribution was calculated from average of three independent determinations.

Conclusions:
A mean particle size distribution (DT50) of 218 - 321 µm, with 1.3 - 3.7% of the samples <100 µm, and 0 - 0.02% of the samples <45 µm was determined for the substance. The result is considered reliable.

Description of key information

Mean particle size: 218 - 321 µm, <100 µm = 1.3 - 3.7% and <45 µm = 0 - 0.2%

Additional information

The particle size distribution of the substance was determined using the sieving method. A mean particle size distribution (DT50) of 218 -321 µm was determined for three samples of the substance. Similarly, about 1.3 - 3.7% of the samples were <100 µm and 0 - 0.02% <45 µm.