Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 616-436-5 | CAS number: 77098-07-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Hydrolysis
Administrative data
- Endpoint:
- hydrolysis
- Type of information:
- calculation (if not (Q)SAR)
- Remarks:
- Migrated phrase: estimated by calculation
- Adequacy of study:
- key study
- Study period:
- February 2018
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- accepted calculation method
- Justification for type of information:
- 1. SOFTWARE : Episuit Hydrowin
2. MODEL (incl. version number) 2.2
3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL: CAS: 77098-07-8
Model used:
SMILES : O=C(c1c(c(c(c(c1C(=O)OCCOCCO)Br)Br)Br)Br)OCC(C)O
CHEM : 1,2-Benzenedicarboxylic acid, 3,4,5,6-tetrabromo-, mixed esters with
diethylene glycol and propylene glycol
MOL FOR: C15 H16 Br4 O7
MOL WT : 627.91
4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
[Explain how the model fulfils the OECD principles for (Q)SAR model validation. Consider attaching the QMRF or providing a link]
- Defined endpoint: ester hydrolysis is well validated in Hyrowin
- Unambiguous algorithm: yes
- Defined domain of applicability:
The following accuracy statistics are available for the Training Set QSARs from Mill et al. (1987):
The ester equation regression has the following statistics:
number = 124
correlation coef (r) = 0.982
correlation coef (r2) = 0.965
- Appropriate measures of goodness-of-fit and robustness and predictivity:
The ester equation regression has the following statistics:
number = 124
correlation coef (r) = 0.982
correlation coef (r2) = 0.965
- Mechanistic interpretation:
the main functional groups of the substance subject to hydrolysis are the ester groups. This is correcly identified by the moidel.
5. APPLICABILITY DOMAIN
- Structural and mechanistic domains:
Currently there is no universally accepted definition of model domain. However, users may wish to consider the possibility that aqueous hydrolysis estimates are less accurate for compounds that have a functional group(s) or other structural features not represented in the training set (see also Section 8.4. below).
Esters are designated by the formula:
R1 - C(=O) - O - R2
In the training set, the R2 substituent is an alkyl carbon or an aromatic carbon. T
- Similarity with analogues in the training set: The substance falls within the applicability domain of the training set.
6. ADEQUACY OF THE RESULT
[Explain how the prediction fits the purpose of classification and labelling and/or risk assessment]: All main components contain similar ester groups and therefore this result is relevant for the assessment.
Data source
Reference
- Reference Type:
- other: software program
- Title:
- Estimation Programs Interface (EPI) Suite™ v3.20 for Microsoft® Windows
- Author:
- Anonymous
- Year:
- 2 010
- Bibliographic source:
- U.S. Environmental Protection Agency, Washington, DC, U.S.A. http://www.epa.gov/opptintr/exposure/pubs/episuite.htm
- Report date:
- 2018
Materials and methods
Test guideline
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- EPI Suite v4.11
- GLP compliance:
- no
Test material
- Reference substance name:
- Reaction products of 3,4,5,6-tetrabromobenzene-1,2-dicarboxylate with 2,2'-oxy-diethanol and 2-epoxypropane
- EC Number:
- 616-436-5
- Cas Number:
- 77098-07-8
- Molecular formula:
- Ester product of C8 H2 Br4 O4 with C4 H10 O3 and C3 H8 O2 and condensation products, thereof.
- IUPAC Name:
- Reaction products of 3,4,5,6-tetrabromobenzene-1,2-dicarboxylate with 2,2'-oxy-diethanol and 2-epoxypropane
- Test material form:
- not specified
- Details on test material:
- Modelling performed with CAS for complete substance, but only mono-ring substance with one ethylene-glycol unit and one propyleneglycol unit modelled. The ester bond is however common to all consituents and is essentially the same. However, limited solubility of the higher molecular weight constituents can limit hyrolysis in practice.
1
- Radiolabelling:
- no
Study design
- Analytical monitoring:
- no
- Estimation method (if used):
- EPI Suite v4.1 HYDROWIN v2.2
Results and discussion
- Transformation products:
- yes
Identity of transformation products
- No.:
- #1
Reference
- Reference substance name:
- Unnamed
- IUPAC name:
- 2,2'-oxydiethanol
- Inventory number:
- InventoryMultipleMappingImpl [inventoryEntryValue=EC 203-872-2]
- CAS number:
- 111-46-6
- Identity:
- Diethylene glycol
- Identity:
- Diethylenglykol
- Molecular formula:
- C4H10O3
- Molecular weight:
- 106.12
- SMILES notation:
- O(CCO)CCO
- InChl:
- 1S/C4H10O3/c5-1-3-7-4-2-6/h5-6H,1-4H2
- Details on hydrolysis and appearance of transformation product(s):
- Pathways for transformation: Hydrolyis of the este bond and formation of 1,2-Benzenedicarboxylic acid, 3,4,5,6-
tetrabromo-, diethyleneglycol and propyleneglycol is the most plausible hydrolysis pathway. Ester hydrolyis is typically fastest in alkaline media,
- Other:
Dissipation DT50 of parent compoundopen allclose all
- Key result
- pH:
- 8
- Temp.:
- 25 °C
- Hydrolysis rate constant:
- ca. 5.89 s-1
- DT50:
- ca. 1.363 d
- Type:
- (pseudo-)first order (= half-life)
- Key result
- pH:
- 7
- Temp.:
- 25 °C
- DT50:
- ca. 13.69 d
- Type:
- (pseudo-)first order (= half-life)
- Other kinetic parameters:
- pH > 8 and 25 deg. C
Kb 1 for the first ester group : 4.32 Lmol-1s-1 (ethyelenglycol ester)
Kb 2 for the second ester group: 1.57 Lmol-1s-1 (propylene glycol ester)
Kb total: 5.89 Lmol-1s-1
Half lives relate to complete hydrolysis of both ester groups.
Any other information on results incl. tables
Pathways for transformation: Hydrolyis of the este bond and formation of 1,2-Benzenedicarboxylic acid, 3,4,5,6-
tetrabromo-, diethyleneglycol and propyleneglycol is the most plausible hydrolysis pathway. Ester hydrolyis is typically fastest in alkaline media,
Applicant's summary and conclusion
- Validity criteria fulfilled:
- yes
- Conclusions:
- Based on QSAR results on ester hydrolysis of the one ring component, a hydrolysis is likely to occur on all ester groups contained in the various components in a similar manner, provided the solubility is sufficient. Hydrolysis constants for the ethyleneglycol ester bond were predicted to be 4.32 Lmol-1s-1 and for the propyleneglycol ester bond 1.57 Lmol-1s-1 at pH > 8 and 25 deg. C.
The hysrolysis constant for the complete hydrolysis was predicted to be 5.89 Lmol-1s-1 at pH> 8 and 25 deg. C.
The half-live for complete hydrolysis of both ester bonds were 1.363 d a.t pH > 8 and 13.69 d at pH 7, both at 25 deg. C - Executive summary:
Based on QSAR results on ester hydrolysis of the one ring component, a hydrolysis is likely to occur on all ester groups contained in the various components in a similar manner, provided the solubility is sufficient. Hydrolysis constants for the ethyleneglycol ester bond were predicted to be 4.32 Lmol-1s-1 and for the propyleneglycol ester bond 1.57 Lmol-1s-1 at pH > 8 and 25 deg. C.
The hydrolysis constant for the complete hydrolysis was predicted to be 5.89 Lmol-1s-1 at pH> 8 and 25 deg. C.
The half-live for complete hydrolysis of both ester bonds were 1.363 d a.t pH > 8 and 13.69 d at pH 7, both at 25 deg. C
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.