Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 700-261-7 | CAS number: 4427-96-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Skin irritation / corrosion
Administrative data
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- From 2019-04-01 to 2019-04-05
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- Study performed to current OECD guidelines with no significant deviations and run in OECD GLP certified lab.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 019
- Report date:
- 2019
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Version / remarks:
- 2016
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- Vinyl ethylene carbonate
- EC Number:
- 700-261-7
- Cas Number:
- 4427-96-7
- Molecular formula:
- C5H6O3
- IUPAC Name:
- Vinyl ethylene carbonate
- Test material form:
- liquid
Constituent 1
- Specific details on test material used for the study:
- Batch No.: A03-18-0081
Purity: ≥99.9%
In vitro test system
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Justification for test system used:
- Recommended test system in international guidelines (OECD and EC).
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm Skin Model
- Tissue batch number(s): 30311 Kit F
TEMPERATURE USED FOR TEST SYSTEM
- Temperature: All incubations, with the exception of the test item incubation of 3 minutes at room temperature, were carried out in a controlled environment, in which optimal conditions were a humid atmosphere of 80 - 100% (actual range 36 - 93%), containing 5.0 ± 0.5% CO2 in air in the dark at 37.0 ± 1.0 °C (actual range 36.8 - 37.9 °C).
REMOVAL OF TEST MATERIAL AND CONTROLS : After the exposure period, the tissues washed with phosphate buffered saline to remove residual test item. The skin inserts were carefully dried. Rinsed tissues were kept in 24 well plates on 300 μL DMEM until 6 tissues (= one application time) were dosed and rinsed.
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: MTT concentrate (5 mg/mL) diluted (1:5) with MTT diluent
- Incubation time: 3 h
- Spectrophotometer: TECAN Infinite® M200 Pro Plate Reader
- Wavelength: 570 nm
- Linear OD range of spectrophotometer: 0.8 - 2.8
NUMBER OF REPLICATE TISSUES: two tissues for 3-minute exposure and two for a 1-hour exposure, 2 tissues for the negative and positive controls for both the 3-minute and 1-hour time point
DECISION CRITERIA
- The test substance is considered to be corrosive to skin if [the viability after 3 minutes exposure is less than 50%, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15%.]
- The test substance is considered to be non-corrosive to skin if [the viability after 3 minutes exposure is greater than or equal to 50% and the viability after 1 hour exposure is greater than or equal to 15%.] - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- TEST MATERIAL
- Amount(s) applied: applied undiluted (50 μL)
NEGATIVE CONTROL
- Amount(s) applied: 50 μL Milli-Q water
POSITIVE CONTROL
- Amount(s) applied: 50 μL 8N KOH - Duration of treatment / exposure:
- 3 minutes and 1 hour
- Number of replicates:
- two tissues for 3-minute exposure and two for a 1-hour exposure, 2 tissues for the negative and positive controls for both the 3-minute and 1-hour time point
Results and discussion
In vitro
Resultsopen allclose all
- Irritation / corrosion parameter:
- % tissue viability
- Value:
- 84
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: The mean relative tissue viability after 3-minute treatment
- Irritation / corrosion parameter:
- % tissue viability
- Value:
- 92
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: The mean relative tissue viability after 1-hour treatment
- Other effects / acceptance of results:
- - OTHER EFFECTS:
- Colour interference with MTT: the test item did not interfere with the MTT endpoint.
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: The absolute mean OD570 (optical density at 570 nm) of the negative control tissues was within the acceptance limits of OECD 431 (lower acceptance limit ≥ 0.8 and upper acceptance limit ≤ 2.8) and the laboratory historical control data range.
- Acceptance criteria met for positive control: The positive control had a mean relative tissue viability of 9.8% after the 1-hour exposure.
- Acceptance criteria met for variability between replicate measurements: In the range of 20 - 100% viability the Coefficient of Variation between tissue replicates was ≤ 15%
Applicant's summary and conclusion
- Interpretation of results:
- other: unclassified
- Conclusions:
- The test item is not corrosive in the in vitro skin corrosion test under the experimental conditions described in this report.
- Executive summary:
The objective of this study was to evaluate the test item for its ability to induce skin corrosion on a human three dimensional epidermal model (EpiDerm (EPI-200)) according to OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method).
The possible corrosive potential of the test item was tested through topical application for 3 minutes and 1 hour. The test item was applied undiluted (50 μL) directly on top of the skin tissue.
The positive control had a mean relative tissue viability of 9.8% after the 1-hour exposure.
The absolute mean OD570 (optical density at 570 nm) of the negative control tissues was within the acceptance limits of OECD 431 (lower acceptance limit ≥0.8 and upper acceptance limit ≤ 2.8) and the laboratory historical control data range. In the range of 20 - 100% viability the Coefficient of Variation between tissue replicates was ≤ 15%, indicating that the test system functioned properly.
Skin corrosion is expressed as the remaining cell viability after exposure to the test item. The relative mean tissue viability obtained after 3-minute and 1-hour treatments with the test item compared to the negative control tissues was 84% and 92%, respectively.
Because the mean relative tissue viability for Vinyl ethylene carbonate was not below 50% after the 3-minute treatment and not below 15% after the 1-hour treatment the test item is considered to be not corrosive.
In conclusion, the test item is not corrosive in the in vitro skin corrosion test under the experimental conditions described in this report.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.