Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 821-184-6 | CAS number: 1777721-60-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 08 February 2018 - 29 March 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 018
- Report date:
- 2018
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: EU method A.24 (Partition coefficient - HPLC method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
Test material
- Reference substance name:
- (2S,3S)-3-[(2-chloro-5-fluoropyrimidin-4-yl)amino]bicyclo[2.2.2]octane-2-carboxylic acid
- EC Number:
- 821-184-6
- Cas Number:
- 1777721-60-4
- Molecular formula:
- C13H15ClFN3O2
- IUPAC Name:
- (2S,3S)-3-[(2-chloro-5-fluoropyrimidin-4-yl)amino]bicyclo[2.2.2]octane-2-carboxylic acid
- Test material form:
- solid: particulate/powder
- Details on test material:
- - Name of test material (as cited in study reports): JNJ-63757096-AAA (T003689)
- Physical state: solid (powder)
- Appearance: white powder
Constituent 1
- Specific details on test material used for the study:
- - Batch n°: I16ED2695
- Analytical purity: 99.3%
- Expiration date: 28 May 2018
- Storage condition: at room temperature
Study design
- Analytical method:
- high-performance liquid chromatography
- photometric method
Results and discussion
Partition coefficientopen allclose all
- Key result
- Type:
- log Pow
- Partition coefficient:
- 0.2
- Temp.:
- 20 °C
- pH:
- 7
- Type:
- log Pow
- Partition coefficient:
- 2.4
- Temp.:
- 20 °C
- pH:
- 3
- Details on results:
- Calculation method
The Pow of the test item was calculated to be 2.4E3 (log Pow 3.4) using the Rekker calculation method.
The calculation of the pKa values in the logarithmn range of 1-14 for acidic and basic groups in the molecular structure of the test item (calculated using the Perrin calculation method) resulted in the pKa value of 5.13 for an acidic group.
Main study
HPLC method at pH 3
The UPLC-UV chromatogram of the test item solution showed 1 test item peak. The calibration curve of the log k' of the reference substances as function of log Pow was: log k' = 0.343 x log Pow - 0.862 (r=0.996, n=18).
HPLC method at pH 7
The UPLC-UV chromatogram of the test item solution showed 1 test item peak. The calibration curve of the log k' of the reference substances as function of log Pow was: log k' = 0.337 x log Pow - 0.846 (r=0.996, n=18).
Detailed results are given in the table in the field 'Any other information on results incl. tables'.
Any other information on results incl. tables
Pow of the test item - pH 3
Substance | tr,1 (min) | tr,2 (min) | mean tr (n=2) | log Pow | Pow |
2 -Butanone | 0.682 | 0.682 | 0.3 | ||
Benzylalcohol | 0.761 | 0.759 | 1.1 | ||
Nitrobenzene | 0.937 | 0.935 | 1.9 | ||
Toluene | 1.487 | 1.484 | 2.7 | ||
1,4 -Dichlorobenzene | 1.930 | 1.926 | 3.4 | ||
Biphenyl | 2.593 | 2.590 | 4.0 | ||
Dibenzyl | 4.322 | 4.320 | 4.8 | ||
Triphenylamine | 7.941 | 7.944 | 5.7 | ||
4,4'-DDT | 11.602 | 11.582 | 6.5 | ||
Test item - test item peak | 1.118 | 1.120 | 1.119 | 2.4 | 2.4E2 |
The average retention time of the unretained (blank) compound formamide was 0.590 min (t0).
Pow of the test item - pH 7
Substance | tr,1 (min) | tr,2 (min) | mean tr (n=2) | log Pow | Pow |
Formamide (t0) | 0.587 | 0.586 | 0.587 | ||
Benzylalcohol | 0.759 | 0.760 | 1.1 | ||
Nitrobenzene | 0.931 | 0.933 | 1.9 | ||
Toluene | 1.470 | 1.474 | 2.7 | ||
1,4 -Dichlorobenzene | 1.900 | 1.906 | 3.4 | ||
Biphenyl | 2.543 | 2.552 | 4.0 | ||
Dibenzyl | 4.213 | 4.230 | 4.8 | ||
Triphenylamine | 7.701 | 7.737 | 5.7 | ||
4,4'-DDT | 11.125 | 11.184 | 6.5 | ||
Test item - test item peak | 0.685 | 0.685 | 0.685 | 0.2 | 1.6E0 |
The average retention time of the unretained (blank) compound formamide was 0.587 min (t0).
Applicant's summary and conclusion
- Conclusions:
- The HPLC method at pH 3 and 7 was applied for the determination of the partition coefficient (Pow) of JNJ-63757096-AAA (T003689). At those pH levels, the test item is predicted to be in its non-ionised form .
The Pow value of the test item at 20°C and pH 7 was 1.6 x 10^(0). This corresponds to a log Pow value of 0.2.
The Pow value of the test item at 20°C and pH 3 was 2.4 x 10^(2). This corresponds to a log Pow value of 2.4.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.