Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 216-231-7 | CAS number: 1530-48-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Study plan dated : 13 Jun 2018 and experimental completion date 24 Jul 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 018
- Report date:
- 2019
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: EU A.24
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
Test material
- Reference substance name:
- Allyltributylphosphonium chloride
- EC Number:
- 216-231-7
- EC Name:
- Allyltributylphosphonium chloride
- Cas Number:
- 1530-48-9
- Molecular formula:
- C15H32P.Cl
- IUPAC Name:
- tributyl(prop-2-en-1-yl)phosphanium chloride
- Reference substance name:
- Tetrahydrothiophene 1,1-dioxide
- EC Number:
- 204-783-1
- EC Name:
- Tetrahydrothiophene 1,1-dioxide
- Cas Number:
- 126-33-0
- Molecular formula:
- C4H8O2S
- IUPAC Name:
- tetrahydrothiophene 1,1-dioxide
- Reference substance name:
- Tributyl-1-propen-1-yl-phosphonium chloride
- Molecular formula:
- C15H32P.Cl
- IUPAC Name:
- Tributyl-1-propen-1-yl-phosphonium chloride
- Test material form:
- other: solid : wax like
- Details on test material:
- Homogeneity : homogeneous if totally melted
Note: For every use the test item was completely melted and the melted test item
was used for the test.
Constituent 1
impurity 1
impurity 2
- Specific details on test material used for the study:
- Designation in Test Facility: 18032901G
Date of Receipt: 29. Mar. 2018
Condition at Receipt: Room temperature, in proper conditions
Homogeneity homogeneous if totally melted
Vapour pressure <0.1 hPa at 30 °C
Stability in solvents H2O: unknown; EtOH: unknown; acetone: unknown; CH3CN: unknown; DMSO: unknown
Solubility in solvents H2O: > 1 g/L; EtOH: unknown; acetone: unknown; CH3CN: unknown; DMSO: unknown
Expiry date 17. Oct. 2019
Storage Room Temperature (20 ± 5°C)
Study design
- Analytical method:
- high-performance liquid chromatography
Results and discussion
Partition coefficient
- Key result
- Type:
- log Pow
- Partition coefficient:
- < 0.3
- Temp.:
- 25 °C
- pH:
- ca. 5
- Details on results:
- Instrument Parameters
Eluent: MeOH/H2O 65/35 (% v/v), ultrasonic degassed, pH ~ 5 (pH paper)
Flow rate. 0.8 mL/min
Injection volume: 10 μL
Column: Luna 3μ C18(2), 100*4.6 mm with precolumn Phenomenex Security Guard C18, 4x3 mm
Column temperature: 25 ± 1 °C
Wavelength for evaluation: 254 nm (reference item mix) 200 nm (test item)
Mobile Phase
A mixture of 65 % methanol and 35 % water, isocratic, was used.
Applicant's summary and conclusion
- Conclusions:
- Variations in the retention times of reference items and test item were very small, demon-strating a stable configuration of the HPLC-column.
The correlation log k / log POW is acceptable: the coefficient of determination r2 was calcu-lated with 0.9527. This value was considered as sufficiently high to use the calibration function for the determination of the log POW of the test item Allyltributylphosphonium chloride.
As dissolved air in the sample results also in a detectable peak, the relative peak area of the test item peak is not 100 %. The test item peak lies within the dead time of the method and not within the range of log POWs of the reference items. It is thus concluded that the test item Allyltributylphosphonium chloride has a log POW of < 0.3.
No observations were made which might cause doubts concerning the validity of the study outcome. - Executive summary:
The peak lies within the dead time of the method and not within the range of log POWs of the reference items. It is thus concluded that the test item Allyltributylphosphonium chloride has a log POW of < 0.3
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.