Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31-1-1990 to 7-3-1990
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP study following recognised guideline but with less than complete reporting.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1990
Report date:
1990

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
(Z)-1,3-dichloropropene
EC Number:
233-195-8
EC Name:
(Z)-1,3-dichloropropene
Cas Number:
10061-01-5
Molecular formula:
C3H4Cl2
IUPAC Name:
1,3-dichloroprop-1-ene
Details on test material:
Batch number 2364 of purity 98.1% w/w

Results and discussion

Flash point
Flash point:
28.5 °C
Atm. press.:
772 mm Hg

Any other information on results incl. tables

The open flash point/fire point was not determinable, as the pilot light could not be lit without igniting the liquid test substance.

Applicant's summary and conclusion

Conclusions:
With a closed flash point of 28.5 ºC, CIS-1,3-DICHLOROPROPENE is classified as a flammable substance under the EU DSD classification scheme.
Executive summary:

The flash and fire points of CIS-1,3-DICHLOROPROPENE were determined in duplicate using the Closed flash point method and the Open flash point/fire point. With a closed flash point of 28.5 ºC, CIS-1,3-DICHLOROPROPENE is classified as a flammable substance. The open flash point/fire point was not determinable, as the pilot light could not be lit without igniting the liquid test substance.