Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with generally accepted scientific standards and described in sufficient detail; however, no GLP-study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
no guideline followed
Deviations:
not applicable
Principles of method if other than guideline:
Test principle: Full range mie scattering theory
GLP compliance:
no
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Bis(2,4-di-tert-butyl-6-methylphenyl)ethyl phosphate
EC Number:
416-140-4
EC Name:
Bis(2,4-di-tert-butyl-6-methylphenyl)ethyl phosphate
Cas Number:
145650-60-8
Molecular formula:
C32H51O3P
IUPAC Name:
bis(2,4-di-tert-butyl-6-methylphenyl) ethyl phosphite
Test material form:
other: Free flowing powder

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
297.628 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
51.175 µm
Percentile:
D50
Mean:
297.628 µm
Percentile:
D90
Mean:
425.207 µm

Any other information on results incl. tables

Volume average particle: 269.559 µm

Surface area/volume: 0.0846 m2/cm3

Refractive Index of sample: 1.51 +0.010i

Applicant's summary and conclusion

Conclusions:
The particle size distribution of the test substance has been determined by laser diffraction (non-GLP, 2015) and the following results have been obtained for the sample tested:
D10 = 51.175 μm
D50 = 297.628 μm= mass median diameter (MMD)
D90 = 425.207 μm