Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-05-03 to 2017-05-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
1.79
Temp.:
20 °C
pH:
7.435

Table 1: Results of Log Pow-Values of the test item

Thiourea (dead time)

Retention Time [min]

 

Solution 1

1strun

1.320

 

2ndrun

1.320

 

Solution 2

1strun

1.320

 

2ndrun

1.320

 

Test Item

Retention Time [min]

Log k'

Log Pow

Mean

Overall Mean

Solution 1

1strun

5.967

0.5466

1.790

1.79

1.79 ± 0.00

2ndrun

5.960

0.5459

1.789

Solution 2

1strun

5.960

0.5459

1.789

1.79

2ndrun

5.960

0.5459

1.789

The given results represent rounded results obtained by calculation with exact raw data.

Conclusions:
The log Pow of the test item was determined to be 1.79 at 20 °C (HPLC column temperature) and pH 7.435 (Eluent).
Executive summary:

The determination of the partition coefficient (n-octanol/water) of the test item was performed according to the OECD Guideline 117: Partition Coefficient (n-Octanol/Water) : High Performance Liquid Chromatography (HPLC) Method. Elution from a C18 column was achieved using a methanol / water eluent with a retention time in a range of retention times of recommended reference items. Thus, the HPLC method was considered to be appropriate for the test item. Six reference items, listed in the guideline, which have known log Pow-values in the range of 0.5 and 3.4 were used. The log Pow-value of the test item was found to be 1.79 at 20 °C (column temperature) and pH 7.435 (Eluent). The acceptance criterium of the guideline was fulfilled.

Description of key information

The log Pow-value of the test item was assessed according to OECD guideline 117 (HPLC Method) and was found to be 1.79 at 20 °C (column temperature) and pH 7.435 (Eluent).

Key value for chemical safety assessment

Log Kow (Log Pow):
1.79
at the temperature of:
20 °C

Additional information

The determination of the partition coefficient (n-octanol/water) of the test item was performed according to OECD Guideline 117: Partition Coefficient (n-Octanol/Water): High Performance Liquid Chromatography (HPLC) Method. Elution from a C18 column was achieved using a methanol/water eluent with a retention time in a range of retention times of recommended reference items. Six reference items, listed in the guideline, which have known log Pow-values in the range of 0.5 and 3.4 were used. The log Pow-value of the test item was found to be 1.79 at 20 °C (column temperature) and pH 7.435 (Eluent). The acceptance criterium of the guideline was fulfilled.